Files
ESP32-S3-LCD-1.3/wiki/pages/link-redundancy.md
T
julian 5fe313b7fa Link protocol v2 receiver, ESP-NOW leg, Patrol gauge outputs, gear pulse
- protocol header v2 copied byte-identical from the 5B repo
- uart_receiver: processFrame() shared by the UART framing task and ESP-NOW,
  version check, dedupe on packet_id+timestamp, per-transport liveness,
  CONFIG cache with sequence number
- espnow_receiver: STA mode, channel hopping while silent, locks on frames
- gauge_outputs: tach on IO7 (LEDC ch2, 14-bit), coolant PWM on IO8 (LEDC
  ch4, 8-bit), config cached in NVS, overrides applied but not saved
- main: gear label from lever + engaged/target (pulses while shifting, red on
  mismatch), icons driven by A's alert bits, gauge update at 5 Hz, link stats
- wiki: temp_stage.cfd (user's old CANNY program) decoded as prior art;
  controller-link, link-redundancy, patrol-gauge-outputs, open-questions
  updated with the bench-verified v2 results and calibration procedure

Co-Authored-By: Claude <noreply@anthropic.com>
2026-09-21 19:12:38 +02:00

4.6 KiB
Raw Blame History

type, tags, updated
type tags updated
concept
link
ble
redundancy
design
esp-now
2026-09-21

Link Redundancy: wired + wireless

Stated goal (user, 2026-09-21): connect B to A "through some serial or BLE, or maybe a combination of both as redundant in case the wired connection is lost." This page is the design space. Status 2026-09-21: ESP-NOW is implemented and bench-verified as the second transport (see below); the RS485 question and BLE remain open. Items are (unverified) unless labelled otherwise.

Why redundancy matters more once B drives gauges

Today a lost link only blanks a secondary display. Once B drives the cluster's tachometer and coolant gauge (patrol-gauge-outputs), a lost link means the driver's primary instruments go dead or, worse, freeze at the last value. The failover policy on B must therefore also define what the gauges do during an outage (drop to zero, hold with a warning, or sweep to a "no data" position).

Transport options

Transport Pros Cons Notes
UART TTL, direct wire (today) trivial, 23 bytes @ 5 Hz is nothing 3.3 V single-ended over a car harness is noise-prone and has no ground-offset tolerance Fine on the bench; questionable in a vehicle over more than a few cm
RS485 pair differential, automotive-grade noise immunity, tens of metres; A already has an SP3485 on its terminal block B has no transceiver — needs a 3.3 V MAX3485/SP3485 module on IO1 (+ a free GPIO if the module lacks auto-direction) This may already be what is wired — see the physical-layer question in controller-link
BLE 5 GATT (A = peripheral notifying, B = central) both boards have BLE 5 (source: waveshare-wiki-esp32-s3-lcd-1-3); connection-oriented, so B gets an explicit disconnect event; notify payload of 23 bytes fits one packet connection setup/reconnect takes hundreds of ms to seconds; BLE stack costs RAM on both ends (NimBLE is the lighter choice on Arduino-ESP32); A's Core 0 already runs Wi-Fi scanning + CAN + UART, and Wi-Fi/BLE coexistence on one radio can add jitter The user's stated candidate
ESP-NOW connectionless, ~ms latency, no pairing state, trivially broadcast the same 23-byte frame; both are ESP32-S3 so it is a one-call API Wi-Fi-based, so it shares the radio with A's Wi-Fi scanning; no link-layer "disconnected" event — liveness must come from the existing 1 s timeout Worth benchmarking against BLE before committing; simpler failover semantics

What was built (2026-09-21, verified on the bench)

  • A broadcasts every frame on both UART1 and ESP-NOW (channel 1, broadcast peer, radio held in STA mode; the WiFi manager's "off" no longer powers the radio down).
  • B receives on both, hands every frame to one processFrame(), dedupes DATA on packet_id + timestamp_ms, and tracks per-transport liveness (uart alive, espnow alive). While ESP-NOW is silent B hops channels 1–13 every 400 ms and locks when frames arrive.
  • Result on the desk: every frame seen on both paths, all duplicates dropped, zero errors. Pulling either path should leave the other carrying the link — not yet tested by physically pulling the wire (unverified).
  • Not built: B talking back, BLE, an on-screen indicator of which path is live (the serial stats line shows it).

Failover design sketch

  1. B keeps one packet consumer. Every transport (UART, BLE/ESP-NOW) feeds validated automotive_data_t frames into the same queue, tagged with a source id.
  2. Deduplicate on packet_id + timestamp_ms (both already in the payload) so a frame arriving on both paths is applied once.
  3. Prefer wired when both are alive; fall to wireless when the wired path has been silent > N ms (N smaller than the display's 1000 ms lost-link threshold, e.g. 400 ms = two missed frames).
  4. Show the active source on the display (small glyph) so a silently degraded wire is noticed on the bench, not in traffic.
  5. Gauge behaviour during a total outage is a separate decision → open-questions.

A-side implication: A must transmit on both paths simultaneously, always — not "switch to BLE when UART fails", because A cannot tell that B stopped hearing it (the link is one-way). Simultaneous transmit is cheap at 5 Hz.

Open decisions

  • BLE vs ESP-NOW for the wireless leg (latency, reconnect behaviour, RAM on A).
  • Whether the wired leg becomes RS485 end-to-end (probably yes if the run is longer than a dash-panel jumper).
  • Whether B should ever talk back (ACK/heartbeat) — would let A alarm on a dead B, at the cost of the current one-way simplicity.

controller-link · patrol-gauge-outputs · esp32-s3-lcd-1-3 · open-questions