- protocol header v2 copied byte-identical from the 5B repo - uart_receiver: processFrame() shared by the UART framing task and ESP-NOW, version check, dedupe on packet_id+timestamp, per-transport liveness, CONFIG cache with sequence number - espnow_receiver: STA mode, channel hopping while silent, locks on frames - gauge_outputs: tach on IO7 (LEDC ch2, 14-bit), coolant PWM on IO8 (LEDC ch4, 8-bit), config cached in NVS, overrides applied but not saved - main: gear label from lever + engaged/target (pulses while shifting, red on mismatch), icons driven by A's alert bits, gauge update at 5 Hz, link stats - wiki: temp_stage.cfd (user's old CANNY program) decoded as prior art; controller-link, link-redundancy, patrol-gauge-outputs, open-questions updated with the bench-verified v2 results and calibration procedure Co-Authored-By: Claude <noreply@anthropic.com>
4.5 KiB
type, tags, updated, raw
| type | tags | updated | raw | ||||||
|---|---|---|---|---|---|---|---|---|---|
| source |
|
2026-09-21 | raw/temp_stage.cfd |
temp_stage.cfd — the user's earlier CannyLab program for the Patrol temp gauge
CannyLab project ("CANNY FUNCTIONAL DIAGRAM FILE", file-format version fields 12 / 2) written by the user some years ago for a CANNY 5.3 pico controller, to drive the Nissan Patrol coolant gauge from the BMW engine's CAN bus. Dropped into raw/ 2026-09-21; file dated 2026-06-04. This is direct prior art for patrol-gauge-outputs: the same job the 1.3 board is about to take over.
How it was read
The format is a proprietary binary, not documented anywhere I know of. It walks as a flat list of [u32 type][u32 length][payload] records — 165 of them, ending exactly at a 16-byte trailer (hash). Block names, port names, constants and a free-text comment are stored in clear. Function-block opcodes are numeric; their meaning below is inferred from the wiring, the constants and the comment, which agree with each other everywhere. Two diagram pages: page 1 = hardware configuration, page 2 = "Temperatura Gauge" (the logic).
Page 1 — hardware configuration (read verbatim from the file)
| Block | Setting |
|---|---|
| CAN Mode | CAN 500k |
| CAN RX IDL (receive ID filter) | constant 0x1D0 |
| CAN RX data | CAN RX D1:D0 (16-bit word, bytes 1:0) |
| DIO Mode IO Channel 1 | OUTPUT; VDD/gnd (push-pull) |
| HR PWM Period | constant 255 |
| HR PWM 1 | Duty / Enable / Pull-up driven from page 2 |
| UART1, UART2 Mode | UART RX/TX 9600-8-N-1-PU, TX LEN 1 — not used by the logic |
Page 2 — the logic (inferred; every constant and the comment match)
CAN Data Received ─┐
AND ──▶ latch(D1:D0) ──▶ take low byte (D0) ──▶ − 48 ──▶ T ("tmp aktuale")
CAN RX IDL == 0x1D0 ┘
Duty = ((T − 40) × 15 + 1100) / 10 (integer arithmetic, constants 40, 15, 1100, 10)
Enable = Pull-up = (T > tmp_min) tmp_min constant = 0 in this file
HR PWM 1 Duty = Enable ? Duty : 0
The comment box (Albanian, translated): "Calculation: D = ((T − RT) × 15 + 1100) / 10. a: D = Duty. b: T = temperature coming from the ECU. c: RT = reference temperature (40 °C). d: 15 → 1.5 (coefficient per degree) × 10. e: 1100 → 110 (duty at 40 °C) × 10. f: everything divided by 10. Note: if temp is not 40, do not activate any function."
Simplified: Duty = 1.5 × T + 50, on a 0–255 period. Points:
| T °C | Duty /255 | % |
|---|---|---|
| 40 | 110 | 43 |
| 60 | 140 | 55 |
| 80 | 170 | 67 |
| 90 | 185 | 73 |
| 100 | 200 | 78 |
| 110 | 215 | 84 |
| 120 | 230 | 90 |
| ≈137 | 255 | 100 (saturates) |
What this establishes
- The CAN decode is the same one the 5B verified in 2026: ID 0x1D0, byte 0, raw − 48 °C
(sibling: 5B wiki → can-id-candidates). Independent confirmation from a working installation years earlier. - The gauge was driven by PWM duty rising with temperature, linearly, with a non-zero floor at 40 °C. Consistent with emulating an NTC sender (resistance falls as temperature rises) through a switch and series resistor.
- The output was the CANNY's own IO channel 1 in push-pull mode with the PWM pull-up enabled — i.e. the gauge line was driven (or a driver stage was fed) directly from the controller pin
(source: file; external circuit unknown). - The linear duty law means the gauge + drive circuit behaved close to linear in duty over 40–120 °C, or the user accepted a linear approximation. Either way this is the °C → duty table to start from.
What it does NOT tell us
- The PWM frequency: "HR PWM Period = 255" is in CANNY timer ticks of an unknown base clock
(unverified). Look up the CANNY 5.3 pico HR PWM clock, or scope the old unit. - The external circuit between the CANNY pin and the gauge sender wire (series resistor value, any transistor). Ask the user / inspect the old harness.
- Whether the cluster is the same one the 1.3 board will drive (assumed yes).
- Why
tmp_minis 0 while the comment says 40: either edited later or the gate was relaxed. With 0 the output is enabled for any positive temperature.
Relevance
- Answers most of open-questions #7 (temp gauge curve) — as a starting table, pending a bench check on the actual needle.
- Sets the initial LEDC design for patrol-gauge-outputs: 8-bit duty,
duty = 1.5·T + 50clamped to 0–255, output enabled only with a valid temperature.