Diag day: Route A+B verified live, DTCs read, donor identified as E60 530d
- diag probe: add mode 03 (diag dtc), BMW KWP on 0x6F1 with extended addressing (diag ident, diag bmw), read-only service whitelist (1A/18/21/22), MAX_PAYLOAD 64->384, full hex+ascii dump of BMW replies - tools/diag_session.py: one-session probe runner, logs into wiki/raw/ - wiki: Route A results (11 mode-01 PIDs, rpm/coolant cross-checked, mode 09 silent), Route B verified (0x6F1 [12] -> 0x612), 1A 86 ident with VIN prefix WBANC92090 (E60 530d), DTCs P0101/P0113/P0500/P0545/P0030 (disconnected-sensor swap leftovers), open-questions #2/#7 updated Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
This commit is contained in:
@@ -89,3 +89,11 @@ User raised temp_pwm_hz to 20000 via the tuning screen; needle now steady at fix
|
||||
## [2026-09-23] update | Tach steppy-needle saga resolved; trim -13; temp gauge stable
|
||||
|
||||
Full day of override-ramp experiments (ignition on, engine off; tools/tach_ramp.py + tach_ramp2.py drive A over serial). Four-layer diagnosis on B, all firmware in the 1.3 repo: (1) 5 Hz staircase -> slew limiter; (2) Arduino ledcChangeFrequency() re-inits the timer mid-period -> replaced LEDC with esp_timer toggle; (3) esp_timer task jitter from WiFi bursts -> hardware-timer ISR, phase-continuous; (4) the floor: the cluster counts pulses in ~150 rpm quanta (alternating +100/+200 needle steps on a clean ramp) -> random dither +/-45 rpm with an adaptive envelope that fades at steady rpm. Scale: cluster over-reads x1.20 low / x1.15 high (nonlinear); user settled tach_trim = -13%. Also found mid-session: user trim change via touchscreen had never registered (B stayed on cfg v99) - config state now verified over serial before every test. [[patrol-instrument-cluster]] rewritten with the saga; new tools: serial_logger.py, serial_cmd.py, tach_ramp*.py, dual_serial_capture.py. Status: RPM and temp gauges "fairly good", tach dither constants may get a future pass.
|
||||
|
||||
## [2026-09-23] ingest | Route A OBD probe - first live run: the DDE answers
|
||||
|
||||
The deferred test-day mission finally executed. `tools/diag_session.py` (new: one serial session, full console log into `wiki/raw/`) ran the `diag` sequence with the engine idling, Launch unplugged. Result: **Route A verified** - the DDE serves generic OBD-II mode 01 on `0x7E8`. Supported PIDs `01,04,05,0B,0C,0D,0F,10,1C,20,21`; rpm and coolant cross-checked live against the broadcast IDs (681 rpm / 64 C, matching). Boost PID `70` absent, mode 09 (VIN/ECU name) silent, MAF/IAT scalings implausible under J1979 (flagged unverified). PID 01: MIL off, **5 stored DTCs** - reading them needs mode 03 (probe extension or Launch). Probe counters clean: 15 req / 12 replies / 3 timeouts / 0 tx failures, no retry storms. Wrote sources/diag-route-a-2026-09-23.md; updated obd-diagnostic-polling (Route A section), open-questions #2 (OBD cannot identify the donor; EDC16 hints) and #7 (DTC path now concrete); raw logs diag-20260923-111737.log + diag-20260923-111851.log.
|
||||
|
||||
## [2026-09-23] ingest | Route B verified, DTCs read, donor identified (E60 530d)
|
||||
|
||||
Second session of the day, no Launch needed. Extended the diag probe (read-only: mode 03 `diag dtc`, BMW KWP `diag ident` / `diag bmw` on 0x6F1 with a 1A/18/21/22 service whitelist; MAX_PAYLOAD 64->384). Results, all on the tapped bus: (1) `diag dtc` read the 5 stored codes - P0101 MAF, P0113 IAT, P0500 VSS, P0545 EGT, P0030 O2 heater - all disconnected-sensor swap leftovers; the "implausible MAF/IAT scaling" flags from the morning are withdrawn (sensor faults). (2) BMW addressing verified live: 0x6F1 [12] -> reply on 0x612; the google-ai clipping's reversed claim is dead. (3) `1A 86` ident (65 B): part numbers 7799764/7799765/7793887, date 2006-03, VIN prefix WBANC92090 -> E60 530d (unverified decode); 22 F190 rejected -> KWP2000 not UDS -> DDE6/EDC16-era. 1A 90 (full VIN) always answers busyRepeatRequest to single-shots. Wrote sources/diag-route-b-2026-09-23.md; updated obd-diagnostic-polling (Route B verified, warning callout resolved), open-questions #2 (donor mostly identified - part-number lookup remains) and #7 (DTCs read), bmw-m57n-engine; raw logs diag-20260923-1241*/1242*/1243*/1245*/1246*.log. Firmware change in src/modules/diag_probe.cpp+.h (design rule kept: still the single transmit path, human-typed, single-shot).
|
||||
|
||||
Reference in New Issue