Rename Controller A/B -> Main CTRL / Inst. Cluster (user); Sleep when the car is off: Settings switch, deep sleep on quiet CAN + idle screen, CAN RX wake, switch mirrored to the cluster; docs
Firmware / build (push) Successful in 7m22s
Firmware / build (push) Successful in 7m22s
This commit is contained in:
@@ -83,7 +83,7 @@ On BMW PT-CAN (Powertrain CAN) networks, data is divided into two categories: **
|
||||
|
||||
1\. Broadcasted Data (Why you see RPM & Temp)
|
||||
|
||||
The DDE (Engine ECU) continuously loops and broadcasts specific telemetry frames that other modules (like the Instrument Cluster, Transmission Control, and Stability Control) *absolutely need* to function.
|
||||
The DDE (Engine ECU) continuously loops and broadcasts specific telemetry frames that other modules (like the Inst. Cluster, Transmission Control, and Stability Control) *absolutely need* to function.
|
||||
|
||||
Bimmerforums.com +1
|
||||
|
||||
|
||||
+4
-3
@@ -12,15 +12,16 @@ Catalog of every page in the wiki. Read this first when answering questions. Kee
|
||||
- [[patrol-instrument-cluster]] — **what the Patrol cluster expects on its inputs**: tach = 2 pulses/rev (verified by calibration), temp = NTC sender 2.1–2.9 kΩ cold → ~250 Ω at 90 °C; the 1 kHz PWM needle-flutter problem and the mitigation ladder (fixed-duty test → 20 kHz → hardware damping)
|
||||
- [[bmw-m57n-engine]] — the 3.0L BMW diesel whose CAN bus we read; E60/E65 donor (confirmed), DDE ECU, auto box with EGS on bus
|
||||
- [[nissan-patrol-swap]] — the target vehicle: Patrol receiving the M57N + BMW auto; the tapped bus is a BMW island in a Nissan
|
||||
- [[esp32-s3-touch-lcd-5b]] — Waveshare 5" display board (Controller A); onboard TJA1051 CAN transceiver, 7–36 V input, pinout, PSRAM/LCD gotchas — **flash writes flicker the RGB panel, full-screen fades stutter, internal RAM nearly full, opening the serial port resets the board unless DTR/RTS are low; Wi-Fi scans caused the flickering dots; all screens hand-coded since 2026-09-27**
|
||||
- [[esp32-s3-touch-lcd-5b]] — Waveshare 5" display board (Main CTRL); onboard TJA1051 CAN transceiver, 7–36 V input, pinout, PSRAM/LCD gotchas — **flash writes flicker the RGB panel, full-screen fades stutter, internal RAM nearly full, opening the serial port resets the board unless DTR/RTS are low; Wi-Fi scans caused the flickering dots; all screens hand-coded since 2026-09-27**
|
||||
|
||||
## Concepts
|
||||
|
||||
- [[can-bus-integration]] — the core challenge; current firmware ID map flagged as placeholder, verification plan
|
||||
- [[driveline-speed-signals]] — **engine / turbine / output-shaft speeds**: turbine speed as physical proof of gear engagement, and the output-shaft field that is our **only road-speed source** (no DSC on this bus) — the feedback variable for a future cruise-control PoC, with the safety envelope that would require
|
||||
- [[dual-controller-architecture]] — Controller A → UART1 + ESP-NOW, protocol v2 → Controller B (1.3" display + Patrol gauge outputs); A owns alerts and the gauge tunables (`cfg` console)
|
||||
- [[dual-controller-architecture]] — Main CTRL → UART1 + ESP-NOW, protocol v2 → Inst. Cluster (1.3" display + Patrol gauge outputs); A owns alerts and the gauge tunables (`cfg` console)
|
||||
- [[obd-diagnostic-polling]] — **why boost / MAF / rail / injection / DTCs never appear on the sniffer** and how a tester gets them: Route A generic OBD-II mode 01 on `0x7DF` and Route B BMW KWP on `0x6F1` → `0x612` — **BOTH VERIFIED WORKING 2026-09-23** (minimal PID set, no boost PID, mode 09 silent; `1A 86` ident identifies the donor; DTCs read via mode 03), the capture-with-Launch procedure (still wanted for the `22 D1xx` live-data identifiers), and why polling is a transmit-on-the-bus design decision
|
||||
- [[ota-updates]] — **Controller A updates itself from Gitea releases**: tag `v*` → CI builds + signs (ECDSA P-256) → Settings → Updates (confirm dialog) or `ota install` (manual, parked, Wi-Fi) pulls over HTTPS from the public repo, verifies, flashes the idle slot, 30 s confirm-or-rollback; **verified end-to-end, from the screen since 2026-09-27 (now v0.1.5)**, release with `git push --follow-tags origin main`; dual-slot partition table; **Controller B card on the Updates page (2026-09-27)**: B pulls its own release, A pairs over the wire (`link pair`), hands over credentials in encrypted frames and triggers - details in B's wiki `controller-b-ota`
|
||||
- [[sleep-when-parked]] — **2026-09-28**: one Settings switch puts both controllers into deep sleep 60 s after the CAN bus goes quiet; Main CTRL wakes on CAN RX (GPIO 16), Inst. Cluster on the UART wire or a 60 s probe boot; bit 7 of `out_enable` carries the switch to B
|
||||
- [[ota-updates]] — **Main CTRL updates itself from Gitea releases**: tag `v*` → CI builds + signs (ECDSA P-256) → Settings → Updates (confirm dialog) or `ota install` (manual, parked, Wi-Fi) pulls over HTTPS from the public repo, verifies, flashes the idle slot, 30 s confirm-or-rollback; **verified end-to-end, from the screen since 2026-09-27 (now v0.1.5)**, release with `git push --follow-tags origin main`; dual-slot partition table; **Inst. Cluster card on the Updates page (2026-09-27)**: B pulls its own release, A pairs over the wire (`link pair`), hands over credentials in encrypted frames and triggers - details in B's wiki `controller-b-ota`
|
||||
|
||||
## Synthesis
|
||||
|
||||
|
||||
+16
-12
@@ -44,15 +44,15 @@ First real dump off the swap's bus, taken with the board's **own new raw-frame l
|
||||
|
||||
## [2026-09-21] update | .docs folder retired; UART spec moved to docs/; board photo ingested
|
||||
|
||||
The repo's `.docs/` folder was deleted (user decision). `CAN_BUS_INTEGRATION.md` documented the dead placeholder IDs and an external transceiver the board does not need — superseded by [[can-id-candidates]] and [[can-bus-integration]]. `UART_PROTOCOL.md` (the packet spec, shared with Controller B) moved to `docs/UART_PROTOCOL.md` as the single copy; Controller B's duplicate was removed. The annotated board photo moved to `raw/` → [[esp32-s3-touch-lcd-5-intro-photo]]: confirms the terminal-block order, that GPIO 44 exits only as the RS485 A/B pair, and that one 120 Ω switch serves both CAN and RS485. Root `CLAUDE.md` corrected: verified CAN ID list replaces the placeholders, `TWAI_MODE_NORMAL` replaces "LISTEN_ONLY", UART TX is GPIO 44 (was written as 43), dummy-data references removed.
|
||||
The repo's `.docs/` folder was deleted (user decision). `CAN_BUS_INTEGRATION.md` documented the dead placeholder IDs and an external transceiver the board does not need — superseded by [[can-id-candidates]] and [[can-bus-integration]]. `UART_PROTOCOL.md` (the packet spec, shared with Inst. Cluster) moved to `docs/UART_PROTOCOL.md` as the single copy; Inst. Cluster's duplicate was removed. The annotated board photo moved to `raw/` → [[esp32-s3-touch-lcd-5-intro-photo]]: confirms the terminal-block order, that GPIO 44 exits only as the RS485 A/B pair, and that one 120 Ω switch serves both CAN and RS485. Root `CLAUDE.md` corrected: verified CAN ID list replaces the placeholders, `TWAI_MODE_NORMAL` replaces "LISTEN_ONLY", UART TX is GPIO 44 (was written as 43), dummy-data references removed.
|
||||
|
||||
**Missing source**: the schematic PDF (`ESP32-S3-Touch-LCD-5-Sch.pdf`) was in `.docs/` at the start of the 2026-09-21 session and was not on disk by the time of this cleanup (never git-tracked). Its net list was read earlier that session and is reflected in [[esp32-s3-touch-lcd-5b]]; re-download it into `raw/` — still on the sourcing wishlist in [[open-questions]].
|
||||
|
||||
Sibling wiki instantiated today at `../../ESP32-S3-LCD-1.3/wiki/` for Controller B (link, redundancy, gauge outputs). Cross-references from there use the text form `(sibling: 5B wiki → page)`.
|
||||
Sibling wiki instantiated today at `../../ESP32-S3-LCD-1.3/wiki/` for Inst. Cluster (link, redundancy, gauge outputs). Cross-references from there use the text form `(sibling: 5B wiki → page)`.
|
||||
|
||||
## [2026-09-21] update | Link protocol v2: ESP-NOW second transport, gear/rpm/alerts on the wire, tunables console
|
||||
|
||||
Firmware (not yet committed): shared header v2 with typed DATA/CONFIG frames; `Tunables` module (gauge calibration + alert thresholds in NVS, `cfg show|set|override|reset` on the USB console); `EspNowLink` broadcasts every frame alongside UART1 (radio now stays in STA mode — WiFiManager's off no longer calls `WIFI_OFF`); CAN driver publishes lever + target/engaged gear nibbles and rpm, and evaluates coolant/gearbox/battery/cooling-demand alerts against the tunables. Bench-verified with Controller B: both transports alive, every frame deduplicated, `cfg override rpm 2000` drove B's tach output at 133.3 Hz. `docs/UART_PROTOCOL.md` rewritten for v2. [[dual-controller-architecture]] and index updated. Build note: IDF 5.5's ESP-NOW send callback takes `wifi_tx_info_t*`; and the two repos must not be built concurrently (shared penv).
|
||||
Firmware (not yet committed): shared header v2 with typed DATA/CONFIG frames; `Tunables` module (gauge calibration + alert thresholds in NVS, `cfg show|set|override|reset` on the USB console); `EspNowLink` broadcasts every frame alongside UART1 (radio now stays in STA mode — WiFiManager's off no longer calls `WIFI_OFF`); CAN driver publishes lever + target/engaged gear nibbles and rpm, and evaluates coolant/gearbox/battery/cooling-demand alerts against the tunables. Bench-verified with Inst. Cluster: both transports alive, every frame deduplicated, `cfg override rpm 2000` drove B's tach output at 133.3 Hz. `docs/UART_PROTOCOL.md` rewritten for v2. [[dual-controller-architecture]] and index updated. Build note: IDF 5.5's ESP-NOW send callback takes `wifi_tx_info_t*`; and the two repos must not be built concurrently (shared penv).
|
||||
|
||||
## [2026-09-21] update | Gauge Tuning screen
|
||||
|
||||
@@ -70,7 +70,7 @@ User clipped a Google AI Mode conversation into `Clippings/` (Obsidian Web Clipp
|
||||
|
||||
User dropped `raw/BMW 335d.csv` and clipped page 1 of the e90post/6post thread "Extended BMW 335d PIDs for Torque" (DWR, 2009 335d = M57N2 on DDE7.3/EDC17CP09) → [[dwr-335d-torque-pids]]. **Every entry is a generic SAE J1979 mode-01 PID** (DWR says so in post 21; header `Auto` = `0x7DF`); nothing BMW-proprietary, nothing broadcast. Two revisions compared: the CSV in `raw/` is the corrected 2017 one (boost ×0.3125 = the J1979 0.03125 kPa/bit; fuel rate ×0.0938 lb/hr; post-#2's ×0.296 and ×5.64 were wrong); residual typos noted (`000031` for 0.0000305, one `+33`). Decoded his table back to SI with the J1979 byte positions. Consequence for us: the generic route is the **cheapest polling experiment** — one `01 00` supported-PID query on `0x7DF` tells whether our DDE answers EOBD on the PT-CAN and which PIDs it has — but the diesel-specific PIDs he relies on for boost (`70`), exhaust pressure (`73`), EGT (`78`), DPF (`7A`), NOx (`83`) are 2007+ J1979 additions an EDC16 almost certainly lacks `(unverified)`, and PID `0B` clips at 255 kPa. [[obd-diagnostic-polling]] restructured into Route A (generic, PID table, first test) and Route B (BMW `0x6F1`/`0x612`). Wishlist: DWR's Testo parameter list (post 175 of the Testo thread). Updated [[open-questions]] #7 + wishlist, index.
|
||||
|
||||
## [2026-09-21] update | `diag` console probe: Controller A can now send OBD-II requests
|
||||
## [2026-09-21] update | `diag` console probe: Main CTRL can now send OBD-II requests
|
||||
|
||||
User decision: build the Route A probe. New module `src/modules/diag_probe.cpp` and a single sanctioned transmit function `CANDriver::transmit()` (single-shot frames, `CANTX,` console echo mirroring `CANRAW,`). Console: `diag pids` (mode-01 supported-PID bitmap scan, blocks 00/20/40…, per-responder summary with PID names), `diag pid <hex>` (one request, decoded for the Route A table incl. PID 70 boost and 78 EGT), `diag vin`, `diag ecu` (mode 09), `diag status`. ISO-TP single/first/consecutive frames reassembled with a `30 00 00` flow control to the responder's physical ID. Guards: one request in flight, refused for 3 s after any foreign tester frame (`0x7DF`/`0x7E0–7`/`0x6F1`), services 01 and 09 only. Console dispatch chained through `Tunables::setExtraCommandHandler()`. Built (1.49 MB) and flashed to COM11; bench check with no bus attached: `diag pids` sent `02 01 00` on `0x7DF`, the TWAI controller reported the single-shot frame un-ACKed, and the probe reported "not ACKed - no other node saw it" rather than blaming the ECU (the summary distinguishes un-ACKed from ACKed-but-silent). CAN-task warnings now take the serial lock so they no longer splice into `CANTX` lines. The wiki's "firmware never transmits" statements are now qualified on [[can-bus-integration]] and [[obd-diagnostic-polling]] (test-day procedure and the three possible outcomes written there). Root `CLAUDE.md` and `docs/UART_PROTOCOL.md` console section updated. Procedure rewritten as numbered steps with all four outcomes (un-ACKed / ACKed-silent / one responder / two responders) and the log-capture command.
|
||||
|
||||
@@ -80,7 +80,7 @@ First in-car test of the dual-controller rig: A reads the bus fine, B receives f
|
||||
|
||||
## [2026-09-22] query | Patrol cluster signal research - tach 2 ppr verified, temp sender curve, flutter plan
|
||||
|
||||
First day driving the real cluster from Controller B through the 2SK3069 low-side stage. Tach: needle tracked at double with ppr=4; user set ppr=2 -> tracks correctly (verified). 2 ppr matches an ECU-driven 4-cyl-style tach input (ZD30-era Y61 hint, unverified) rather than the TD42 alternator-W-terminal scheme. Temp gauge on IO8: needle flutters at temp_pwm_hz=1 kHz. Researched: stock Patrol sender is an NTC (2.1-2.9k @ 20C, 0.68-1k @ 50C, 236-260R @ 90C; patrol4x4/sensorgal), gauge is current-measuring; community PWM-gauge experience says flutter dies at ~40-50 kHz. Mitigation ladder filed: fixed-duty override test (data vs electrical), cfg set temp_hz 20000 (firmware clamp), then raise clamp / series drain resistor (~100-240R, also bounds full-on beyond-hot short) / gauge-side cap. Temp law must be re-derived after (FET inverts duty sense). Filed [[patrol-instrument-cluster]]; index updated. Earlier same day: [[canny-5-3-pico-gauge-drive]] hypothesis effectively confirmed by the needles moving through the FET; gauge-output disable bits found off during bench test (B console "disabled") - re-enabled via tuning screen.
|
||||
First day driving the real cluster from Inst. Cluster through the 2SK3069 low-side stage. Tach: needle tracked at double with ppr=4; user set ppr=2 -> tracks correctly (verified). 2 ppr matches an ECU-driven 4-cyl-style tach input (ZD30-era Y61 hint, unverified) rather than the TD42 alternator-W-terminal scheme. Temp gauge on IO8: needle flutters at temp_pwm_hz=1 kHz. Researched: stock Patrol sender is an NTC (2.1-2.9k @ 20C, 0.68-1k @ 50C, 236-260R @ 90C; patrol4x4/sensorgal), gauge is current-measuring; community PWM-gauge experience says flutter dies at ~40-50 kHz. Mitigation ladder filed: fixed-duty override test (data vs electrical), cfg set temp_hz 20000 (firmware clamp), then raise clamp / series drain resistor (~100-240R, also bounds full-on beyond-hot short) / gauge-side cap. Temp law must be re-derived after (FET inverts duty sense). Filed [[patrol-instrument-cluster]]; index updated. Earlier same day: [[canny-5-3-pico-gauge-drive]] hypothesis effectively confirmed by the needles moving through the FET; gauge-output disable bits found off during bench test (B console "disabled") - re-enabled via tuning screen.
|
||||
|
||||
## [2026-09-22] update | Temp gauge flutter resolved: temp_hz 1 kHz -> 20 kHz
|
||||
|
||||
@@ -110,9 +110,9 @@ The capture-with-Launch session, finally run (engine idling, our read-only seria
|
||||
|
||||
Tightened the live-data findings after checking the full capture: the Launch used only 1A/2C/22/23 - NO 10 (session), 27 (security), or 3E (tester-present). So self-polling a 2C value (e.g. rail pressure) needs only the 2C 10 15E0 define + 2C 10 00DF poll, no secret; the earlier 21-block NRCs (0x22/0x33) are a different mechanism and do not gate 2C. Corrected the "needs session/define handshake" wording in launch-capture-2026-09-23.md and obd-diagnostic-polling. Recorded the design decision (user, 2026-09-23): active polling, if built, lives behind a password-protected Diagnostics screen (authorized-tech gate, manual, refuses while scan tool connected, read-oriented services) - open-questions #12, and a project memory so the capability is not re-researched later.
|
||||
|
||||
## [2026-09-26] build | OTA updates for Controller A
|
||||
## [2026-09-26] build | OTA updates for Main CTRL
|
||||
|
||||
Repartitioned A to dual OTA slots (2 x 7.9 MB, SPIFFS dropped, nvs/otadata offsets kept - tunables v150 survived the one-time USB flash on COM10, verified). New src/modules/ota_update.cpp + include/config/ota_config.h: manual `ota status|check|install|rollback` console; HTTPS pull from the (now public) Gitea repo's latest release, ECDSA P-256 signature over "patrol-a|version|sha256" checked before download, image hashed while streaming, parked gate before download and before slot switch, rollback via verifyRollbackLater() override + 30 s confirm. TLS trusts ISRG Root X1 + Root YR (both verified against the server chain). CI: .gitea/workflows/firmware.yml (main -> rolling unsigned pre-release main-latest; v* tag -> signed release with manifest.txt). Decisions: manual trigger (future Diagnostics screen), public repos instead of a device token, Controller B to be updated by A over ESP-NOW (wire is one-way). Wrote pages/ota-updates.md. Pending: BMW_NISSAN_FIRMWARE_SIGNING_KEY repo secret, enable repo Actions, first v* tag to test end-to-end.
|
||||
Repartitioned A to dual OTA slots (2 x 7.9 MB, SPIFFS dropped, nvs/otadata offsets kept - tunables v150 survived the one-time USB flash on COM10, verified). New src/modules/ota_update.cpp + include/config/ota_config.h: manual `ota status|check|install|rollback` console; HTTPS pull from the (now public) Gitea repo's latest release, ECDSA P-256 signature over "patrol-a|version|sha256" checked before download, image hashed while streaming, parked gate before download and before slot switch, rollback via verifyRollbackLater() override + 30 s confirm. TLS trusts ISRG Root X1 + Root YR (both verified against the server chain). CI: .gitea/workflows/firmware.yml (main -> rolling unsigned pre-release main-latest; v* tag -> signed release with manifest.txt). Decisions: manual trigger (future Diagnostics screen), public repos instead of a device token, Inst. Cluster to be updated by A over ESP-NOW (wire is one-way). Wrote pages/ota-updates.md. Pending: BMW_NISSAN_FIRMWARE_SIGNING_KEY repo secret, enable repo Actions, first v* tag to test end-to-end.
|
||||
|
||||
## [2026-09-26] build | OTA bring-up: Wi-Fi switch, ESP-NOW, memory
|
||||
|
||||
@@ -148,7 +148,7 @@ User asked to refactor the Settings and Gauge Tuning UX, save the Wi-Fi connecti
|
||||
|
||||
## [2026-09-26] ingest | Schematic re-downloaded; VOUT = H8 solder jumper (3V3 default / 5V)
|
||||
|
||||
User asked whether VOUT becomes 5 V by "unsoldering the resistor". Re-fetched `ESP32-S3-Touch-LCD-5-Sch.pdf` into `raw/` (closes the wishlist item) → [[esp32-s3-touch-lcd-5-schematic]]. Answer: VOUT is net `I2C_VCC`, picked by **`H8`, a 3-pad solder jumper** (1 = 3V3, 2 = VOUT, 3 = 5V; "the default paste is 3V3"): open the 1–2 bridge, bridge 2–3, never all three. The terminal-block I2C lines are level-shifted (NDC7002N, 4.7 k pull-ups to `I2C_VCC`) so they follow the choice. 5 V rail is a SY8293 buck rated 2 A ("run the line at 2A"), screen ≈550 mA, so ≈1 A spare for a load such as Controller B `(unverified estimate)`; not on USB power. Also indexed: SD SPI pins (IO11/12/13, CS EXIO4), CAN IO15/16 and RS485 IO43/44 confirmed. Updated [[esp32-s3-touch-lcd-5b]], [[open-questions]] wishlist, index.
|
||||
User asked whether VOUT becomes 5 V by "unsoldering the resistor". Re-fetched `ESP32-S3-Touch-LCD-5-Sch.pdf` into `raw/` (closes the wishlist item) → [[esp32-s3-touch-lcd-5-schematic]]. Answer: VOUT is net `I2C_VCC`, picked by **`H8`, a 3-pad solder jumper** (1 = 3V3, 2 = VOUT, 3 = 5V; "the default paste is 3V3"): open the 1–2 bridge, bridge 2–3, never all three. The terminal-block I2C lines are level-shifted (NDC7002N, 4.7 k pull-ups to `I2C_VCC`) so they follow the choice. 5 V rail is a SY8293 buck rated 2 A ("run the line at 2A"), screen ≈550 mA, so ≈1 A spare for a load such as Inst. Cluster `(unverified estimate)`; not on USB power. Also indexed: SD SPI pins (IO11/12/13, CS EXIO4), CAN IO15/16 and RS485 IO43/44 confirmed. Updated [[esp32-s3-touch-lcd-5b]], [[open-questions]] wishlist, index.
|
||||
|
||||
## [2026-09-27] query | Open question 13 reviewed with the user: full fix committed, dots not gone
|
||||
|
||||
@@ -195,13 +195,13 @@ Tag build died at the link step: `ModuleNotFoundError: No module named 'SCons.To
|
||||
Second tag build (pioarduino core fork in the workflow) succeeded: release `v0.1.7` on Gitea at 18:28 with `firmware.bin` (1,722,464 B), `firmware.elf`, `manifest.txt` (target patrol-a, sha256 `a2949644…4c09`, ECDSA sig), built from `8e739fa`. Off-device check: downloaded binary's SHA-256 and size match the manifest. The bench board (dev build on COM14) could not `ota check` — Wi-Fi off and no saved network at that moment — so the first on-device install of v0.1.7 is the user's, from Settings → Updates. Expected on the board: "Version v0.1.7 is available", install with the screen lit and the progress bar, restart, `A v0.1.7` bottom-right; the Updates page then says up to date.
|
||||
|
||||
|
||||
## [2026-09-27] update | Controller B updates from A's screen: link_peer, two-way maintenance frames, Updates page with two cards
|
||||
## [2026-09-27] update | Inst. Cluster updates from A's screen: link_peer, two-way maintenance frames, Updates page with two cards
|
||||
|
||||
Implemented A's half of B's OTA (design in B's wiki `controller-b-ota`). Shared `automotive_data.h` (+ new `link_secure.h`, both byte-identical in the two repos): `STATUS` 0x03 B → A, `PAIR` 0x04 A → B wire-only, `SECURE` 0x05 A → B (AES-256-GCM under the pairing key; inner `OTA_CMD` / `WIFI_CREDS`), `PACKET_MAX_PAYLOAD` 64 → 160, `PACKET_VERSION` unchanged (DATA/CONFIG bytes identical). New `src/modules/link_peer.cpp`: pairing key in NVS `linkpeer`, `link pair` sends the key ×3 over UART1 only (`UARTManager::sendWire()`), B's STATUS kept + logged, automatic push of the remembered Wi-Fi network to B (hash-compared, ≥ 15 s apart, FORGET when A forgets), `requestCheck/requestInstall` for the screen behind `Ota::isParked()` + A on Wi-Fi. `EspNowLink` gained a receive callback (IDF 5.5 `esp_now_recv_info_t`) and `sendTo()`; `WiFiManager::getSavedCredentials()` (for LinkPeer only, never printed). Settings → Updates rebuilt as two cards (Controller A / Controller B) that fit the 484 px page without scrolling. Bench: B heard within seconds (`link status`: MAC, `dev`, heap 234 KB), refusals correct; `link pair` cannot be confirmed because **no wire is connected on the bench** (B reports `uart silent`). Build notes: `pio` from PowerShell only (idf_tools refuses MSYS); first build after the B project reinstalls Arduino 3.3.3 and may fail once with a `TypeError` - rerun.
|
||||
Implemented A's half of B's OTA (design in B's wiki `controller-b-ota`). Shared `automotive_data.h` (+ new `link_secure.h`, both byte-identical in the two repos): `STATUS` 0x03 B → A, `PAIR` 0x04 A → B wire-only, `SECURE` 0x05 A → B (AES-256-GCM under the pairing key; inner `OTA_CMD` / `WIFI_CREDS`), `PACKET_MAX_PAYLOAD` 64 → 160, `PACKET_VERSION` unchanged (DATA/CONFIG bytes identical). New `src/modules/link_peer.cpp`: pairing key in NVS `linkpeer`, `link pair` sends the key ×3 over UART1 only (`UARTManager::sendWire()`), B's STATUS kept + logged, automatic push of the remembered Wi-Fi network to B (hash-compared, ≥ 15 s apart, FORGET when A forgets), `requestCheck/requestInstall` for the screen behind `Ota::isParked()` + A on Wi-Fi. `EspNowLink` gained a receive callback (IDF 5.5 `esp_now_recv_info_t`) and `sendTo()`; `WiFiManager::getSavedCredentials()` (for LinkPeer only, never printed). Settings → Updates rebuilt as two cards (Main CTRL / Inst. Cluster) that fit the 484 px page without scrolling. Bench: B heard within seconds (`link status`: MAC, `dev`, heap 234 KB), refusals correct; `link pair` cannot be confirmed because **no wire is connected on the bench** (B reports `uart silent`). Build notes: `pio` from PowerShell only (idf_tools refuses MSYS); first build after the B project reinstalls Arduino 3.3.3 and may fail once with a `TypeError` - rerun.
|
||||
|
||||
## [2026-09-27] verify | Controller B updated from A's console, end to end (details in B's wiki log)
|
||||
## [2026-09-27] verify | Inst. Cluster updated from A's console, end to end (details in B's wiki log)
|
||||
|
||||
With the wire connected: pairing, credential push, check and install of B's first signed release `v0.1.0` all worked from A's `link` console; B rebooted and confirmed. A's side needed one cosmetic fix (missing separator in the "Controller B update: failed - <reason>" log line), rebuilt and flashed COM14. Left for the user: tap Check / Install on the Controller B card of Settings → Updates on the next B release and watch B's progress line.
|
||||
With the wire connected: pairing, credential push, check and install of B's first signed release `v0.1.0` all worked from A's `link` console; B rebooted and confirmed. A's side needed one cosmetic fix (missing separator in the "Inst. Cluster update: failed - <reason>" log line), rebuilt and flashed COM14. Left for the user: tap Check / Install on the Inst. Cluster card of Settings → Updates on the next B release and watch B's progress line.
|
||||
|
||||
## [2026-09-27] update | Wi-Fi chip and blinking alert banner on every screen; Driveline reds
|
||||
|
||||
@@ -210,3 +210,7 @@ User: show Wi-Fi on every screen (top-right) and give a sense of urgency when a
|
||||
## [2026-09-28] update | No invented data: A starts with nothing valid and forgets everything when the bus stops
|
||||
|
||||
User: "if there is no info from CAN bus, no values should be shown". Until now `UARTManager::initializeDefaultData()` seeded 89.0 / 85.0 degC and 12.45 V with their valid flags SET, so a bench B (and a car with CAN off) showed plausible fake readings. Now the shared structure starts zeroed with `valid_flags = 0` and lever UNKNOWN; every field is valid only after a CAN frame filled it. `can_driver.cpp` gained `clearSharedData()`, called on CAN stop and on the bus-silence timeout (which already stopped the link) so stale values never come back marked valid. The `DEFAULT_*` block left the shared header (copied to B, `cmp`-identical). Driveline and B already key everything off the valid flags, so they show `--` / hidden needles. Flashed COM14; B's RX log now shows `Valid:0x00`. Released as v0.1.9 (v0.1.8, tagged minutes earlier, still carries the defaults - do not install it).
|
||||
|
||||
## [2026-09-28] update | Boards renamed Main CTRL / Inst. Cluster; "Sleep when the car is off" switch
|
||||
|
||||
User renamed Controller A → **Main CTRL** and Controller B → **Inst. Cluster** across both repos (comments, UI text, workflow names, wiki) and reworded the Updates page; committed here together with the sleep feature. New `power_manager.cpp` + Settings → System switch (NVS `sleep_en`, default OFF), see [[sleep-when-parked]]: deep sleep after 60 s of quiet CAN bus + idle touch + no update job, wake on CAN RX GPIO 16 (ext0, pull-up, TWAI stopped first). The switch travels to the Inst. Cluster as bit 7 of `out_enable` in CONFIG (no version bump). Console `sleep status | on | off | now`. Bench lesson the same evening: the switch was turned on with CAN on and no bus, so the Main CTRL slept a minute later and its USB-CDC port vanished (a deep-sleeping S3 has no USB) - only the reset button or a power cycle brings it back; touching the screen within the minute keeps it awake. Inst. Cluster side verified (see its log): sleep at 60 s of link silence, timer wake after exactly 60 s, 4 s probe with the panel dark, sleep again.
|
||||
|
||||
@@ -6,7 +6,7 @@ updated: 2026-09-22
|
||||
|
||||
# CANNY 5.3 pico vs ESP32-S3: driving the Patrol cluster
|
||||
|
||||
Why the user's old CANNY-based setup moves the Patrol tach and our ESP32 (Controller B, IO7) does not. Researched 2026-09-22 after the first in-car test of the dual-controller rig: temp needle parked mid-scale, tach dead ([[dual-controller-architecture]]).
|
||||
Why the user's old CANNY-based setup moves the Patrol tach and our ESP32 (Inst. Cluster, IO7) does not. Researched 2026-09-22 after the first in-car test of the dual-controller rig: temp needle parked mid-scale, tach dead ([[dual-controller-architecture]]).
|
||||
|
||||
## The working reference setup `(verified)`
|
||||
|
||||
@@ -48,7 +48,7 @@ ESP32 IOx ──[R ~1k]── G/B N-MOSFET (logic-level, e.g. 2N7002/AO3400) o
|
||||
- If the cluster input turns out to have no internal pull-up, add an external ~4.7–10 kΩ to +12 V.
|
||||
- On hand (2026-09-22): a **2SK3069** (N-ch, 60 V / 75 A, 4 V-drive class) — hugely oversized but suitable; planned for the tach channel with 220 Ω gate series + 10 kΩ gate pulldown `(source: alltransistors.com 2SK3069)`.
|
||||
- **Never** connect the 12 V-pulled gauge line directly to an ESP32 pin, including in open-drain mode — the pin is not 12 V tolerant.
|
||||
- Grounds must be common: cluster GND ↔ Controller B GND.
|
||||
- Grounds must be common: cluster GND ↔ Inst. Cluster GND.
|
||||
|
||||
## Open items
|
||||
|
||||
|
||||
@@ -9,27 +9,27 @@ updated: 2026-09-27
|
||||
The system is two ESP32-S3 boards linked by UART **and ESP-NOW** (repo, protocol v2 since 2026-09-21):
|
||||
|
||||
```
|
||||
BMW M57N CAN bus ──▶ Controller A ──UART1 + ESP-NOW, 5 Hz──▶ Controller B ──▶ Patrol tach + temp gauge
|
||||
BMW M57N CAN bus ──▶ Main CTRL ──UART1 + ESP-NOW, 5 Hz──▶ Inst. Cluster ──▶ Patrol tach + temp gauge
|
||||
(this repo: (ESP32-S3-LCD-1.3,
|
||||
5" 1024×600 display) 1.3" round display, gauge outputs)
|
||||
```
|
||||
|
||||
- **Controller A** — [[esp32-s3-touch-lcd-5b]]: listens to the CAN bus, renders the main UI, and re-broadcasts a compact sensor packet over UART1 (GPIO 43/44, 115200 baud) at 5 Hz.
|
||||
- **Controller B** — ESP32-S3-Touch-LCD-1.3: a secondary display fed purely by that UART stream. Lives in a sibling repo (`bmw-patrol/` parent directory).
|
||||
- **Main CTRL** — [[esp32-s3-touch-lcd-5b]]: listens to the CAN bus, renders the main UI, and re-broadcasts a compact sensor packet over UART1 (GPIO 43/44, 115200 baud) at 5 Hz.
|
||||
- **Inst. Cluster** — ESP32-S3-Touch-LCD-1.3: a secondary display fed purely by that UART stream. Lives in a sibling repo (`bmw-patrol/` parent directory).
|
||||
|
||||
## Link protocol v2 (repo, 2026-09-21)
|
||||
|
||||
`0xAA | 0x02 | type | length | payload | XOR | 0x55`, identical on UART1 (GPIO 44 → SP3485 → `485_A`/`485_B`) and ESP-NOW broadcast (channel 1). DATA frames (lever, target/engaged gear nibbles, rpm, temps, battery, alert bitmap, valid flags) every 200 ms; CONFIG frames (`link_config_t`: Patrol gauge calibration + alert thresholds, edited on A via the `cfg` serial console and stored in NVS) on change and every 5 s. Alerts are decided here; B only renders them. Spec: `docs/UART_PROTOCOL.md`. Bench-verified with both transports live and B deduplicating every frame `(verified 2026-09-21)`.
|
||||
|
||||
**ESP-NOW and Wi-Fi share the radio** `(verified 2026-09-26)`. When A joins a Wi-Fi network (for OTA), its channel follows the AP (seen: 6, 9, 11) and B hops to find it; ESP-NOW kept running (6,410 frames, 0 failed). Until 2026-09-26 the Wi-Fi code powered the radio off on connect/disconnect (`WiFi.disconnect(true)`), which silently killed ESP-NOW and left B on the wire only — fixed, and `EspNowLink::send()` now re-initialises ESP-NOW if the driver drops it. Planned: **Controller B's firmware updates will travel from A over ESP-NOW** (bidirectional, unlike the one-way wire) → [[ota-updates]].
|
||||
**ESP-NOW and Wi-Fi share the radio** `(verified 2026-09-26)`. When A joins a Wi-Fi network (for OTA), its channel follows the AP (seen: 6, 9, 11) and B hops to find it; ESP-NOW kept running (6,410 frames, 0 failed). Until 2026-09-26 the Wi-Fi code powered the radio off on connect/disconnect (`WiFi.disconnect(true)`), which silently killed ESP-NOW and left B on the wire only — fixed, and `EspNowLink::send()` now re-initialises ESP-NOW if the driver drops it. Planned: **Inst. Cluster's firmware updates will travel from A over ESP-NOW** (bidirectional, unlike the one-way wire) → [[ota-updates]].
|
||||
|
||||
**A keeps the ESP-NOW channel stable (v0.1.5, 2026-09-27)** `(repo)`: Wi-Fi auto-reconnect is off. A tries the remembered network once at boot and once after a drop, then parks the radio back on channel 1 — an endless reconnect (e.g. driving away from home Wi-Fi) would keep hopping channels under the link to B. Scans happen only when someone opens the Wi-Fi page or taps Scan.
|
||||
|
||||
Controller B's side of this (receiver, ESP-NOW channel hopping, gauge outputs, bench wiring) is documented in the sibling wiki: `../../ESP32-S3-LCD-1.3/wiki/pages/controller-link.md` and `patrol-gauge-outputs.md`.
|
||||
Inst. Cluster's side of this (receiver, ESP-NOW channel hopping, gauge outputs, bench wiring) is documented in the sibling wiki: `../../ESP32-S3-LCD-1.3/wiki/pages/controller-link.md` and `patrol-gauge-outputs.md`.
|
||||
|
||||
## Why it matters for the wiki
|
||||
|
||||
Any change to what data we extract from the [[can-bus-integration]] ripples into this packet **and** into Controller B's parser — both ends must move together: edit `include/protocol/automotive_data.h` here, bump `PACKET_VERSION`, copy the header byte-identical to B (B rejects other versions).
|
||||
Any change to what data we extract from the [[can-bus-integration]] ripples into this packet **and** into Inst. Cluster's parser — both ends must move together: edit `include/protocol/automotive_data.h` here, bump `PACKET_VERSION`, copy the header byte-identical to B (B rejects other versions).
|
||||
|
||||
## Related
|
||||
|
||||
|
||||
@@ -6,7 +6,7 @@ updated: 2026-09-27
|
||||
|
||||
# Waveshare ESP32-S3-Touch-LCD-5B
|
||||
|
||||
Controller A of the [[dual-controller-architecture]] — the main in-cabin display. SKU 28151, the 1024×600 capacitive-touch variant of the LCD-5 family. Primary reference: [[esp32-s3-touch-lcd-5b-waveshare-wiki]].
|
||||
Main CTRL of the [[dual-controller-architecture]] — the main in-cabin display. SKU 28151, the 1024×600 capacitive-touch variant of the LCD-5 family. Primary reference: [[esp32-s3-touch-lcd-5b-waveshare-wiki]].
|
||||
|
||||
## Specs (source: waveshare-wiki)
|
||||
|
||||
@@ -22,7 +22,7 @@ Controller A of the [[dual-controller-architecture]] — the main in-cabin displ
|
||||
- Draw: ~450 mA @ 5 V (~2.3 W)
|
||||
- Remaining caveat: automotive transient/load-dump spikes (ISO 7637) can exceed 36 V `(unverified)` → [[open-questions]]
|
||||
- **Power path** (source: [[esp32-s3-touch-lcd-5-schematic]]): VIN → 1N5822 reverse diode + SMAJ36CA TVS → SY8293 buck (2 A, "run the line at 2A") → 5 V rail → 3.3 V LDO. Screen alone ≈550 mA @ 5 V.
|
||||
- **VOUT terminal = `I2C_VCC`, selected by solder jumper `H8`** (pad 1 = 3V3, pad 2 = VOUT, pad 3 = 5V; factory bridge 1–2 = 3.3 V). For 5 V: open 1–2, bridge 2–3, never all three. The external SDA/SCL are level-shifted (NDC7002N + 4.7 kΩ pull-ups to `I2C_VCC`), so the I2C lines follow. Headroom for a load on VOUT@5 V from the 12 V input ≈1 A `(unverified estimate)` — enough to power Controller B. Not on USB-only power.
|
||||
- **VOUT terminal = `I2C_VCC`, selected by solder jumper `H8`** (pad 1 = 3V3, pad 2 = VOUT, pad 3 = 5V; factory bridge 1–2 = 3.3 V). For 5 V: open 1–2, bridge 2–3, never all three. The external SDA/SCL are level-shifted (NDC7002N + 4.7 kΩ pull-ups to `I2C_VCC`), so the I2C lines follow. Headroom for a load on VOUT@5 V from the 12 V input ≈1 A `(unverified estimate)` — enough to power Inst. Cluster. Not on USB-only power.
|
||||
|
||||
> [!warning] Operating temperature 0–65 °C (source: waveshare-wiki)
|
||||
> Tight for a car: sub-zero winters and sun-baked dashboards both fall outside spec. → [[open-questions]]
|
||||
@@ -39,7 +39,7 @@ Controller A of the [[dual-controller-architecture]] — the main in-cabin displ
|
||||
|
||||
| Interface | Details |
|
||||
|-----------|---------|
|
||||
| RS485 | SP3485, auto TX/RX direction; terminal block used for UART1 → Controller B, GPIO 43/44, 115200 baud `(repo)` |
|
||||
| RS485 | SP3485, auto TX/RX direction; terminal block used for UART1 → Inst. Cluster, GPIO 43/44, 115200 baud `(repo)` |
|
||||
| Isolated I/O | Optocoupler digital in 5–36 V (dry/wet contact), open-drain out sinking 450 mA/ch — could read ignition-on or drive a relay later |
|
||||
| I2C | Terminal block SDA/SCL, level-shifted to `I2C_VCC` (= VOUT, 3.3 V or 5 V via `H8`); CH422G expander occupies 0x20–0x27 & 0x30–0x3F, GT911 touch at 0x5D — avoid these addresses |
|
||||
| RTC | PCF85063 + CR927 coin cell |
|
||||
|
||||
@@ -6,7 +6,7 @@ updated: 2026-09-23
|
||||
|
||||
# OBD / Diagnostic Polling
|
||||
|
||||
Why some values never appear on the sniffer, how a scan tool gets them, and what it would take for Controller A to do the same. Several pages have linked here since July ([[can-id-candidates]], [[open-questions]] #7); the page was created on the [[google-ai-dde7m57-pids]] ingest, 2026-09-21.
|
||||
Why some values never appear on the sniffer, how a scan tool gets them, and what it would take for Main CTRL to do the same. Several pages have linked here since July ([[can-id-candidates]], [[open-questions]] #7); the page was created on the [[google-ai-dde7m57-pids]] ingest, 2026-09-21.
|
||||
|
||||
## Broadcast vs polled
|
||||
|
||||
@@ -59,7 +59,7 @@ The [[dwr-335d-torque-pids]] source is a worked, gauge-checked set of J1979 mode
|
||||
| `02 01 73` / `78` / `7A` / `83` | — | exhaust pressure / EGT / DPF ΔP / NOx — same caveat; DPF/SCR rows are meaningless on an M57N anyway |
|
||||
|
||||
- **First test = the `01 00` bitmap query.** One frame on `0x7DF` with the engine running (no scan tool attached) answers both open points at once: does this DDE speak EOBD on the PT-CAN at all, and which PIDs does it offer. No reply → the DDE serves EOBD on K-line (or not on this bus) and only Route B remains.
|
||||
- **Implemented on Controller A (2026-09-21) `(repo)`** as the `diag` console command — see *Firmware: the `diag` probe* below. The whole test is `diag pids` typed on the USB console.
|
||||
- **Implemented on Main CTRL (2026-09-21) `(repo)`** as the `diag` console command — see *Firmware: the `diag` probe* below. The whole test is `diag pids` typed on the USB console.
|
||||
- Route A cannot give fault codes beyond generic mode `03` DTCs (P0xxx) — BMW-specific codes need Route B.
|
||||
|
||||
## Route B — BMW proprietary (KWP2000 on `0x6F1` → `0x612`) — **VERIFIED WORKING (2026-09-23)**
|
||||
@@ -89,7 +89,7 @@ This depends on the DDE variant, which is still open ([[open-questions]] #2, [[b
|
||||
|
||||
## Firmware: the `diag` probe `(repo, 2026-09-21)`
|
||||
|
||||
Controller A now has **one** transmit path onto the PT-CAN: `CANDriver::transmit()`, called only by `src/modules/diag_probe.cpp`. It sends nothing on its own; every frame is typed by a human on the USB console.
|
||||
Main CTRL now has **one** transmit path onto the PT-CAN: `CANDriver::transmit()`, called only by `src/modules/diag_probe.cpp`. It sends nothing on its own; every frame is typed by a human on the USB console.
|
||||
|
||||
| Command | What it sends | What it prints |
|
||||
|---|---|---|
|
||||
@@ -128,7 +128,7 @@ Run via `tools/diag_session.py` (one serial session, logs straight into `wiki/ra
|
||||
- **The decode recipe (proven 2026-09-23):** log `CANRAW` while the Launch shows a live value → find the `2C 10 <id>` / `6C 10 <data>` pair whose data tracks the reading → calibrate scale against the display at two operating points (idle + a blip). One session per parameter. Boost, MAF, injection quantity, EGTs all reachable this way. Worked example: [[launch-capture-2026-09-23]] (rail pressure).
|
||||
- A continuous poller (Route A or B) would reuse the same transmit path with a fixed request list: one request per ≥100 ms, one identifier at a time, only while no scan tool is connected, never a session-control or write service. Still a design decision: a request storm or a malformed frame can disturb the DDE/EGS.
|
||||
- **What Route B self-polling actually requires (settled 2026-09-23):** just the `2C 10 15 E0` define then the `2C 10 <id>` poll — **no diagnostic session (`10`), no security access (`27`), no tester-present (`3E`)**, proven from the full Launch capture ([[launch-capture-2026-09-23]]). The `21`-block NRCs (0x22/0x33) that earlier looked like a session/security wall are a *different mechanism* and do not gate the `2C` path. `2C` is not strictly read-only (it writes a dynamic-identifier definition — harmless), so it stays out of the probe whitelist by policy.
|
||||
- **Design decision — the "Diagnostics" screen (2026-09-23):** if active polling is ever built, it lives behind a **password-protected Diagnostics screen** on Controller A (authorized-technician gate), triggered manually, only while no scan tool is connected, read-oriented services only. This is the deliberate on/off switch for transmit-on-the-bus — not a background poller. Not built yet; captured here so the capability and its guard rails are not re-researched later.
|
||||
- **Design decision — the "Diagnostics" screen (2026-09-23):** if active polling is ever built, it lives behind a **password-protected Diagnostics screen** on Main CTRL (authorized-technician gate), triggered manually, only while no scan tool is connected, read-oriented services only. This is the deliberate on/off switch for transmit-on-the-bus — not a background poller. Not built yet; captured here so the capability and its guard rails are not re-researched later.
|
||||
- Protocol v2 dropped the `fault_codes` field in favour of the alert bitmap ([[dual-controller-architecture]]); polled values would need new DATA fields.
|
||||
- The same request path would also be the only way to read DTCs (service `0x18`/`0x19`, variant-dependent) → [[open-questions]] #7.
|
||||
|
||||
|
||||
@@ -24,7 +24,7 @@ The research frontier. Answering any of these should trigger updates across the
|
||||
|
||||
## Design decisions (parked, not blocking)
|
||||
|
||||
12. **The "Diagnostics" screen (planned 2026-09-23).** Active diagnostic polling — replaying the `2C` live-data reads we decoded ([[launch-capture-2026-09-23]]) so values like rail pressure appear on Controller A without the Launch — is now technically unblocked (no session/security needed). Intended design when built: a **password-protected Diagnostics screen**, authorized-technician access only, manual trigger, refuses while a scan tool is connected, read-oriented services only. The same gate covers the general transmit-on-the-bus decision. This is deliberately deferred, but the capability, the byte sequences, and these guard rails are recorded so the work resumes from here, not from scratch. OTA check/install was meant to live here too (2026-09-26); **decided otherwise 2026-09-27**: it is on the Settings screen behind a confirm dialog ([[ota-updates]]). Whatever password this screen gets must be stored as a salted hash in NVS because the firmware is public. → [[obd-diagnostic-polling]], [[dual-controller-architecture]], [[ota-updates]]
|
||||
12. **The "Diagnostics" screen (planned 2026-09-23).** Active diagnostic polling — replaying the `2C` live-data reads we decoded ([[launch-capture-2026-09-23]]) so values like rail pressure appear on Main CTRL without the Launch — is now technically unblocked (no session/security needed). Intended design when built: a **password-protected Diagnostics screen**, authorized-technician access only, manual trigger, refuses while a scan tool is connected, read-oriented services only. The same gate covers the general transmit-on-the-bus decision. This is deliberately deferred, but the capability, the byte sequences, and these guard rails are recorded so the work resumes from here, not from scratch. OTA check/install was meant to live here too (2026-09-26); **decided otherwise 2026-09-27**: it is on the Settings screen behind a confirm dialog ([[ota-updates]]). Whatever password this screen gets must be stored as a salted hash in NVS because the firmware is public. → [[obd-diagnostic-polling]], [[dual-controller-architecture]], [[ota-updates]]
|
||||
|
||||
## Project context
|
||||
|
||||
|
||||
@@ -6,7 +6,7 @@ updated: 2026-09-27
|
||||
|
||||
# OTA Firmware Updates
|
||||
|
||||
How Controller A updates itself from this repo's Gitea releases, why each piece is the way it is, and what is still to do (Controller B). Built 2026-09-26. Design decisions by the user are marked **(decision)**.
|
||||
How Main CTRL updates itself from this repo's Gitea releases, why each piece is the way it is, and what is still to do (Inst. Cluster). Built 2026-09-26. Design decisions by the user are marked **(decision)**.
|
||||
|
||||
## The pipeline
|
||||
|
||||
@@ -16,7 +16,7 @@ git push tag vX.Y.Z ──► Gitea Actions (.gitea/workflows/firmware.yml, runn
|
||||
sign "patrol-a|vX.Y.Z|<sha256>" with secret BMW_NISSAN_FIRMWARE_SIGNING_KEY
|
||||
release vX.Y.Z: firmware.bin + firmware.elf + manifest.txt
|
||||
│ public repo, HTTPS, no token
|
||||
Controller A Settings → Updates → Install ◄──┘ (or `ota install`; parked, Wi-Fi joined)
|
||||
Main CTRL Settings → Updates → Install ◄──┘ (or `ota install`; parked, Wi-Fi joined)
|
||||
GET /api/v1/repos/art/ESP32-S3-Touch-LCD-5B/releases/latest → tag
|
||||
GET /releases/download/<tag>/manifest.txt → verify signature FIRST
|
||||
GET /releases/download/<tag>/firmware.bin → idle slot, hashed while streaming
|
||||
@@ -50,11 +50,11 @@ Known quirk: `ota status` shows the *other* slot's "built" date from the framewo
|
||||
|
||||
## Decisions and why
|
||||
|
||||
- **Manual trigger only (decision, 2026-09-26).** An install ends in a reboot, which blanks Controller B's gauges; nothing checks or installs in the background.
|
||||
- **Manual trigger only (decision, 2026-09-26).** An install ends in a reboot, which blanks Inst. Cluster's gauges; nothing checks or installs in the background.
|
||||
- **On the Settings screen, behind a confirm dialog (decision, 2026-09-27)** — replacing the earlier plan to put it on the password-gated Diagnostics screen. Settings → Updates shows installed vs latest and a **Check for updates** button; **Install vX** appears only when the latest release differs and asks "Install vX? The screen goes dark for about a minute… only while parked". The user chose a confirm dialog over a PIN: the parked gate and the signature already guard the dangerous parts; a PIN can come with the Diagnostics screen ([[open-questions]] #12). The `ota` console stays for bench work and `rollback`.
|
||||
- **Parked gate** `(repo)`: refused if engine rpm > 0 / run state running or starting, output shaft turning, or lever in a drive gear. A silent bus (>2 s no frames: ignition off, bench) counts as parked. Checked before the download **and again** before the slot switch. `ota check` is exempt (read-only).
|
||||
- **HTTPS pull from a public repo (decision).** Both repos were made public 2026-09-26 so the device needs **no token** — the same reasoning as `parking_solution`'s public releases mirror: a read token in shipped firmware leaks with the device. History was scanned before/after going public: no secrets, no full VIN (only the 10-char prefix in ident logs), no SSIDs `(verified 2026-09-26)`.
|
||||
- **Signed images (decision).** HTTPS only proves the file came from the server; the ECDSA P-256 signature proves it came from our CI key. The signed statement is `target|version|sha256`, so a Controller B image can't be installed on A even with a shared key, and the manifest version can't be swapped. The firmware contains no secrets, so public binaries are fine — **keep it that way**: the future Diagnostics-screen password must be a salted hash in NVS, never a literal in source.
|
||||
- **Signed images (decision).** HTTPS only proves the file came from the server; the ECDSA P-256 signature proves it came from our CI key. The signed statement is `target|version|sha256`, so a Inst. Cluster image can't be installed on A even with a shared key, and the manifest version can't be swapped. The firmware contains no secrets, so public binaries are fine — **keep it that way**: the future Diagnostics-screen password must be a salted hash in NVS, never a literal in source.
|
||||
- **TLS trust = Let's Encrypt roots, not the leaf** `(verified 2026-09-26)`: the server chain is leaf (SAN `git.infra.msai.al`) → YR2 → Root YR (cross-signed by ISRG Root X1). Both ISRG Root X1 (to 2035) and Root YR (to 2045) are embedded in `include/config/ota_config.h`, and each verifies the chain alone. Leaf certs rotate ~90 days — never pin them. The framework's mbedtls has `MBEDTLS_HAVE_TIME_DATE` off, so no NTP is needed (and cert dates aren't checked; the signature is the real guarantee).
|
||||
- **Rollback**: the framework bootloader has `CONFIG_BOOTLOADER_APP_ROLLBACK_ENABLE=y`, but Arduino's `initArduino()` marks a new image valid *before* `setup()`. `ota_update.cpp` overrides `verifyRollbackLater()` → the image stays PENDING_VERIFY until `Ota::tick()` confirms it after 30 s. Consequence: **power off within 30 s of an update's first boot = back to the old version** (by design).
|
||||
|
||||
@@ -106,9 +106,9 @@ Wi-Fi must be joined first — Settings → Wi-Fi (remembered from then on) or `
|
||||
- **Joining Wi-Fi killed ESP-NOW**: the Wi-Fi task used `WiFi.disconnect(true)` (true = radio off), which drops ESP-NOW; B then ran on the wire only. Now `WiFi.disconnect()`, and `EspNowLink::send()` re-initialises ESP-NOW if the driver ever drops it. Verified: joined Personal1 (channel 9), ESP-NOW 195 sent / 0 failed.
|
||||
- `showConnectionResult()` took the LVGL lock with a 0 ms try-lock, ignored the result, and touched widgets that are NULL off the Settings screen — now waits for the lock and null-checks. It still showed **no success feedback** on screen (user: "a disaster UX") — resolved by the hand-coded Settings screen in v0.1.5 ([[open-questions]] #14).
|
||||
|
||||
## Controller B (implemented 2026-09-27)
|
||||
## Inst. Cluster (implemented 2026-09-27)
|
||||
|
||||
The 2026-09-26 idea (A streams B's image over ESP-NOW) was dropped for a **pull design** the user chose on 2026-09-27: B downloads its own signed release (target `patrol-b`, B's repo, same key) over Wi-Fi; A only hands over the credentials and the trigger. Full design, verification state and the first-pairing procedure live in B's wiki (`../../ESP32-S3-LCD-1.3/wiki/pages/controller-b-ota.md`). A's side: `src/modules/link_peer.cpp` - `link pair` sends a random key over the UART wire once (never by radio; both repos are public), B's `STATUS` frames (version, phase, progress) arrive over ESP-NOW unicast, credentials and OTA commands go to B inside AES-256-GCM `SECURE` frames, and Settings → Updates gained a **Controller B** card (Installed / Latest / Check / Install) next to Controller A's. B's install is behind the same parking gate plus "A must be on Wi-Fi" (same AP ⇒ same channel ⇒ B's progress frames keep arriving). Console: `link status | pair | unpair | creds | ota check | ota install [force] | ota rollback`. **Verified end-to-end on the bench 2026-09-27**: `link pair` over the wire, automatic credential push, `link ota check` / `link ota install` from A's console took B from `dev` to `v0.1.0` (1,248,432 B in ~50 s), B rebooted, reported `v0.1.0` and confirmed itself after 30 s. The Updates-page buttons share the same request functions but have not been tapped yet.
|
||||
The 2026-09-26 idea (A streams B's image over ESP-NOW) was dropped for a **pull design** the user chose on 2026-09-27: B downloads its own signed release (target `patrol-b`, B's repo, same key) over Wi-Fi; A only hands over the credentials and the trigger. Full design, verification state and the first-pairing procedure live in B's wiki (`../../ESP32-S3-LCD-1.3/wiki/pages/controller-b-ota.md`). A's side: `src/modules/link_peer.cpp` - `link pair` sends a random key over the UART wire once (never by radio; both repos are public), B's `STATUS` frames (version, phase, progress) arrive over ESP-NOW unicast, credentials and OTA commands go to B inside AES-256-GCM `SECURE` frames, and Settings → Updates gained a **Inst. Cluster** card (Installed / Latest / Check / Install) next to Main CTRL's. B's install is behind the same parking gate plus "A must be on Wi-Fi" (same AP ⇒ same channel ⇒ B's progress frames keep arriving). Console: `link status | pair | unpair | creds | ota check | ota install [force] | ota rollback`. **Verified end-to-end on the bench 2026-09-27**: `link pair` over the wire, automatic credential push, `link ota check` / `link ota install` from A's console took B from `dev` to `v0.1.0` (1,248,432 B in ~50 s), B rebooted, reported `v0.1.0` and confirmed itself after 30 s. The Updates-page buttons share the same request functions but have not been tapped yet.
|
||||
|
||||
## Related
|
||||
|
||||
|
||||
@@ -6,7 +6,7 @@ updated: 2026-09-22
|
||||
|
||||
# Patrol instrument cluster — signal expectations
|
||||
|
||||
What the target vehicle's cluster ([[nissan-patrol-swap]]) needs on its tach and temp inputs, from the first day of driving it with Controller B's outputs through the low-side FET stage ([[canny-5-3-pico-gauge-drive]]). Patrol generation still unidentified — Y60/GQ vs Y61/GU matters for gauge internals → [[open-questions]].
|
||||
What the target vehicle's cluster ([[nissan-patrol-swap]]) needs on its tach and temp inputs, from the first day of driving it with Inst. Cluster's outputs through the low-side FET stage ([[canny-5-3-pico-gauge-drive]]). Patrol generation still unidentified — Y60/GQ vs Y61/GU matters for gauge internals → [[open-questions]].
|
||||
|
||||
## Tachometer
|
||||
|
||||
|
||||
@@ -0,0 +1,31 @@
|
||||
---
|
||||
type: concept
|
||||
tags: [power, sleep, settings, verified]
|
||||
updated: 2026-09-28
|
||||
---
|
||||
|
||||
# Sleep when the car is off
|
||||
|
||||
User request 2026-09-28: both boards sit on permanent 12 V, so they must stop burning power when the CAN bus goes quiet. One switch, **Settings → System → "Sleep when the car is off"** (NVS `sleep_en`, default OFF), rules both controllers: the Main CTRL mirrors it into the CONFIG frame as `CFG_SLEEP_WHEN_SILENT` (bit 7 of `out_enable`, byte layout unchanged, `PACKET_VERSION` stays 2), and the Inst. Cluster caches CONFIG in NVS, so it knows the setting even after the Main CTRL has gone to sleep.
|
||||
|
||||
## Main CTRL (`src/modules/power_manager.cpp`)
|
||||
|
||||
Deep sleep when **all** of: switch on; CAN switched on but the bus quiet for 60 s (an ignition-on car never stops talking, so "quiet" = key off); nobody touched the screen for 60 s (`lv_disp_get_inactive_time`); no update running here or reported by the Inst. Cluster; up for at least 60 s. Sequence: `Tunables::flush()`, backlight off, `CANDriver::stop()` (frees GPIO 16 from TWAI), pull-up on GPIO 16, `esp_sleep_enable_ext0_wakeup(GPIO 16, low)`, `esp_deep_sleep_start()`. Wake = the first CAN frame pulls RX low → full reboot (~3 s to the Driveline); the boot log says `woke up: CAN bus activity`. Nothing else wakes it: with no bus (bench) only the reset button / a power cycle does, and the USB port is gone while asleep. Console: `sleep status | on | off | now`.
|
||||
|
||||
## Inst. Cluster (`src/modules/power_manager.cpp`)
|
||||
|
||||
Deep sleep when the bit is set, no DATA frame on any transport for 60 s, no update job, up ≥ 60 s. Gauges driven low and backlight off first. Two wake sources: **UART RX IO1 low** (the Main CTRL's first frame on the wire) and a **60 s timer**. A timer wake is a *probe boot*: setup skips its serial waits, the panel stays dark, and after 4 s without a frame the board sleeps again; if the Main CTRL is heard (ESP-NOW or wire) brightness is restored and the boot continues normally. This is what wakes a radio-only installation (no wire in the car).
|
||||
|
||||
## Verified 2026-09-28 (bench)
|
||||
|
||||
See the log entry of the day: switch → CONFIG → Inst. Cluster within a CONFIG period; `sleep now` on the Inst. Cluster and its wake.
|
||||
|
||||
## Not verified
|
||||
|
||||
- The Main CTRL's own sleep and CAN wake need the car (a quiet bus that later talks). Bench boards have no bus, so they would never wake.
|
||||
- Deep-sleep current of either board (Waveshare boards keep their LDO/USB bridge powered).
|
||||
- Whether the TJA1051's RXD idles high with the transceiver powered but the bus off (expected).
|
||||
|
||||
## Related
|
||||
|
||||
[[ota-updates]] · [[esp32-s3-touch-lcd-5b]] · (sibling wiki: controller-link, patrol-gauge-outputs)
|
||||
@@ -6,7 +6,7 @@ updated: 2026-09-23
|
||||
|
||||
# Route A probe — first live run (2026-09-23)
|
||||
|
||||
First execution of the [[obd-diagnostic-polling]] Route A test: the `diag` console probe on Controller A, engine idling, Launch unplugged, tapped PT-CAN. Two sessions, raw console logs (CANRAW + CANTX + diag output interleaved):
|
||||
First execution of the [[obd-diagnostic-polling]] Route A test: the `diag` console probe on Main CTRL, engine idling, Launch unplugged, tapped PT-CAN. Two sessions, raw console logs (CANRAW + CANTX + diag output interleaved):
|
||||
|
||||
- `raw/diag-20260923-111737.log` — `pids`, `pid 0C`, `pid 05`, `pid 0B`, `pid 70`, `vin`, `ecu`, `status`
|
||||
- `raw/diag-20260923-111851.log` — `pid 10`, `pid 04`, `pid 0F`, `pid 0D`, `pid 1C`, `pid 01`, `pid 21`, `status`
|
||||
|
||||
@@ -20,7 +20,7 @@ raw: raw/ESP32-S3-Touch-LCD-5-details-intro.jpg
|
||||
|
||||
## Relevance
|
||||
|
||||
- Confirms the terminal-block signal set and that the RS485 pair is the only UART1 exit → `(sibling: 1.3 wiki → controller-link)` open question #1 on how the wire to Controller B is really made
|
||||
- Confirms the terminal-block signal set and that the RS485 pair is the only UART1 exit → `(sibling: 1.3 wiki → controller-link)` open question #1 on how the wire to Inst. Cluster is really made
|
||||
- Confirms one shared termination switch for CAN and RS485 — keep it **OFF** when tapping the vehicle CAN bus, which also leaves the RS485 link unterminated on this end
|
||||
- Strapping pads IO0/IO3/IO4/IO46 exist as solder points — the only bare GPIO access on the board, and all four are already committed (G3, VSYNC, CTP_IRQ, HSYNC)
|
||||
|
||||
|
||||
@@ -19,7 +19,7 @@ Raw: `raw/ESP32-S3-Touch-LCD-5-Sch.pdf` (3 sheets, V1.2), re-downloaded 2026-09-
|
||||
## 5 V rail budget (for whatever hangs on VOUT)
|
||||
|
||||
- `VIN` (7–36 V terminal) → `D17` 1N5822 reverse-protection Schottky + `D3` SMAJ36CA TVS → `U1` **SY8293** synchronous buck → **`DC_5V`**, `L3` 4.7 µH 8 A, note *"Run the line at current 2A"*. `DC_5V` feeds the 5 V rail (and VBUS via `Q4` AO3401 ideal-diode-style switch).
|
||||
- Sheet note: *"The screen itself consumes close to 550 mA"*; the wiki's whole-board figure is ~450 mA @ 5 V. Realistic headroom on VOUT@5 V from the 12 V input: **roughly 1 A**, comfortably enough for Controller B (~150–200 mA) `(unverified estimate; the regulator is rated for 2 A total)`.
|
||||
- Sheet note: *"The screen itself consumes close to 550 mA"*; the wiki's whole-board figure is ~450 mA @ 5 V. Realistic headroom on VOUT@5 V from the 12 V input: **roughly 1 A**, comfortably enough for Inst. Cluster (~150–200 mA) `(unverified estimate; the regulator is rated for 2 A total)`.
|
||||
- On USB-only power the 5 V rail is the host's 500 mA — do not load VOUT then.
|
||||
- Caveat for the vehicle: the 36 V TVS is the only transient clamp; the ISO 7637 concern in [[open-questions]] #6 stands.
|
||||
|
||||
|
||||
@@ -23,7 +23,7 @@ Official product documentation for the ESP32-S3-Touch-LCD-5 family. Covers four
|
||||
- **120 Ω termination resistor switch, OFF by default** — correct setting for tapping into an existing, already-terminated vehicle bus; leave it off.
|
||||
|
||||
**Other onboard peripherals:**
|
||||
- RS485 via SP3485, automatic TX/RX direction switching (this is the terminal block the firmware uses for UART1 → Controller B `(repo)`).
|
||||
- RS485 via SP3485, automatic TX/RX direction switching (this is the terminal block the firmware uses for UART1 → Inst. Cluster `(repo)`).
|
||||
- Optocoupler-isolated digital I/O: inputs 5–36 V (dry/wet contact, NPN or PNP), open-drain outputs sinking up to 450 mA/channel.
|
||||
- PCF85063 RTC with CR927 coin-cell holder.
|
||||
- TF card slot (SD_CS must be driven via CH422G EXIO4).
|
||||
|
||||
@@ -6,7 +6,7 @@ updated: 2026-09-23
|
||||
|
||||
# Launch live-data capture — rail pressure decoded (2026-09-23)
|
||||
|
||||
The capture-with-Launch session that [[obd-diagnostic-polling]] had been pointing at since July, finally run. Engine idling, our read-only logger (`tools/serial_logger.py`) on Controller A's USB recording the full `CANRAW` stream while the Launch polled the DDE; then the user selected **Rail Pressure (actual)** and blipped to 2500 rpm for a second calibration point. Raw: `raw/serial-COM10-20260923-163511.log` (~13 MB, both halves of every exchange).
|
||||
The capture-with-Launch session that [[obd-diagnostic-polling]] had been pointing at since July, finally run. Engine idling, our read-only logger (`tools/serial_logger.py`) on Main CTRL's USB recording the full `CANRAW` stream while the Launch polled the DDE; then the user selected **Rail Pressure (actual)** and blipped to 2500 rpm for a second calibration point. Raw: `raw/serial-COM10-20260923-163511.log` (~13 MB, both halves of every exchange).
|
||||
|
||||
## Headline: rail pressure actual is decoded and VERIFIED
|
||||
|
||||
@@ -41,7 +41,7 @@ This is the key operational finding: **rail pressure is served in the DDE's defa
|
||||
- **The method generalises**: any value the Launch will display can be decoded the same way — capture the `2C`/`6C` pair while its screen shows the number, calibrate scale against the display at two points. Boost, MAF, injection quantity, EGTs are each one session away. See [[obd-diagnostic-polling]] "Beyond the probe".
|
||||
- **Self-poll is feasible without any secret.** To read rail pressure ourselves: send the one-time define `2C 10 15 E0`, then poll `2C 10 00 DF` → parse `6C 10 HHLL`. **No `10` session, no `27` security, no `3E` tester-present required** (proven above). The only barriers are our own choices, not the ECU's — see the two below.
|
||||
- **It is still a transmit-on-the-bus action, and `2C` is not strictly read-only** (it writes a definition into the ECU's dynamic-identifier table — harmless, but a state change). So it stays outside the current probe whitelist by policy.
|
||||
- **Intended home (design decision, 2026-09-23):** any active polling belongs behind a **password-protected "Diagnostics" screen** on Controller A — authorized-technician gate — never a background/automatic poller and never while a scan tool is connected. Records [[open-questions]]; not built yet.
|
||||
- **Intended home (design decision, 2026-09-23):** any active polling belongs behind a **password-protected "Diagnostics" screen** on Main CTRL — authorized-technician gate — never a background/automatic poller and never while a scan tool is connected. Records [[open-questions]]; not built yet.
|
||||
- No EGS traffic (`0x618`) — only the DDE (`0x612`) answered; the Launch was on an engine page.
|
||||
|
||||
## Related
|
||||
|
||||
Reference in New Issue
Block a user