@@ -19,7 +19,7 @@ Raw: `raw/ESP32-S3-Touch-LCD-5-Sch.pdf` (3 sheets, V1.2), re-downloaded 2026-09-
|
||||
## 5 V rail budget (for whatever hangs on VOUT)
|
||||
|
||||
- `VIN` (7–36 V terminal) → `D17` 1N5822 reverse-protection Schottky + `D3` SMAJ36CA TVS → `U1` **SY8293** synchronous buck → **`DC_5V`**, `L3` 4.7 µH 8 A, note *"Run the line at current 2A"*. `DC_5V` feeds the 5 V rail (and VBUS via `Q4` AO3401 ideal-diode-style switch).
|
||||
- Sheet note: *"The screen itself consumes close to 550 mA"*; the wiki's whole-board figure is ~450 mA @ 5 V. Realistic headroom on VOUT@5 V from the 12 V input: **roughly 1 A**, comfortably enough for Controller B (~150–200 mA) `(unverified estimate; the regulator is rated for 2 A total)`.
|
||||
- Sheet note: *"The screen itself consumes close to 550 mA"*; the wiki's whole-board figure is ~450 mA @ 5 V. Realistic headroom on VOUT@5 V from the 12 V input: **roughly 1 A**, comfortably enough for Inst. Cluster (~150–200 mA) `(unverified estimate; the regulator is rated for 2 A total)`.
|
||||
- On USB-only power the 5 V rail is the host's 500 mA — do not load VOUT then.
|
||||
- Caveat for the vehicle: the 36 V TVS is the only transient clamp; the ISO 7637 concern in [[open-questions]] #6 stands.
|
||||
|
||||
|
||||