Rename Controller A/B -> Main CTRL / Inst. Cluster (user); Sleep when the car is off: Settings switch, deep sleep on quiet CAN + idle screen, CAN RX wake, switch mirrored to the cluster; docs
Firmware / build (push) Successful in 7m22s
Firmware / build (push) Successful in 7m22s
This commit is contained in:
@@ -6,7 +6,7 @@ updated: 2026-09-23
|
||||
|
||||
# Launch live-data capture — rail pressure decoded (2026-09-23)
|
||||
|
||||
The capture-with-Launch session that [[obd-diagnostic-polling]] had been pointing at since July, finally run. Engine idling, our read-only logger (`tools/serial_logger.py`) on Controller A's USB recording the full `CANRAW` stream while the Launch polled the DDE; then the user selected **Rail Pressure (actual)** and blipped to 2500 rpm for a second calibration point. Raw: `raw/serial-COM10-20260923-163511.log` (~13 MB, both halves of every exchange).
|
||||
The capture-with-Launch session that [[obd-diagnostic-polling]] had been pointing at since July, finally run. Engine idling, our read-only logger (`tools/serial_logger.py`) on Main CTRL's USB recording the full `CANRAW` stream while the Launch polled the DDE; then the user selected **Rail Pressure (actual)** and blipped to 2500 rpm for a second calibration point. Raw: `raw/serial-COM10-20260923-163511.log` (~13 MB, both halves of every exchange).
|
||||
|
||||
## Headline: rail pressure actual is decoded and VERIFIED
|
||||
|
||||
@@ -41,7 +41,7 @@ This is the key operational finding: **rail pressure is served in the DDE's defa
|
||||
- **The method generalises**: any value the Launch will display can be decoded the same way — capture the `2C`/`6C` pair while its screen shows the number, calibrate scale against the display at two points. Boost, MAF, injection quantity, EGTs are each one session away. See [[obd-diagnostic-polling]] "Beyond the probe".
|
||||
- **Self-poll is feasible without any secret.** To read rail pressure ourselves: send the one-time define `2C 10 15 E0`, then poll `2C 10 00 DF` → parse `6C 10 HHLL`. **No `10` session, no `27` security, no `3E` tester-present required** (proven above). The only barriers are our own choices, not the ECU's — see the two below.
|
||||
- **It is still a transmit-on-the-bus action, and `2C` is not strictly read-only** (it writes a definition into the ECU's dynamic-identifier table — harmless, but a state change). So it stays outside the current probe whitelist by policy.
|
||||
- **Intended home (design decision, 2026-09-23):** any active polling belongs behind a **password-protected "Diagnostics" screen** on Controller A — authorized-technician gate — never a background/automatic poller and never while a scan tool is connected. Records [[open-questions]]; not built yet.
|
||||
- **Intended home (design decision, 2026-09-23):** any active polling belongs behind a **password-protected "Diagnostics" screen** on Main CTRL — authorized-technician gate — never a background/automatic poller and never while a scan tool is connected. Records [[open-questions]]; not built yet.
|
||||
- No EGS traffic (`0x618`) — only the DDE (`0x612`) answered; the Launch was on an engine page.
|
||||
|
||||
## Related
|
||||
|
||||
Reference in New Issue
Block a user