CAN raw logger + toggle fix; wiki: first live capture confirms ID map
Firmware — make the board a working CAN sniffer and fix real bugs: - can_driver: add raw candump-style logger (CANRAW,<ts>,<id>,<extd>,<dlc>,<hex>), capturing every frame incl. unknown IDs for offline decoding. Single atomic write per frame. - serial_lock: new global serial mutex so concurrent task writes (CAN logger, UART 5Hz log, heartbeat) no longer splice mid-line. Corruption 3.2% -> 1.4%. - Fix CAN toggle: the switch had no event handler registered, so it never started CAN and reverted on screen change. Wire up onCANBusToggle. - platformio: route Serial to native USB-CDC (USB_MODE=1, CDC_ON_BOOT=1) so the ~486 frame/s stream isn't throttled by the 115200 UART ceiling; bump monitor baud to 921600. - tools/fix_toolchain_path.py: pre-build workaround for pioarduino nesting the Xtensa toolchain bin under a subdir that never reaches PATH. - Correct misleading "LISTEN_ONLY" log string (driver runs TWAI_MODE_NORMAL). Wiki — ingest the first live capture off the real swap bus: - raw/can-capture-2026-07-15-gearshift.csv (20,596 frames) + sources page. - Research map CONFIRMED: 0x1D0/0x1D2/0x0B5/0x3B4 all live; placeholder IDs (0x4F/0x55/0x201/0x1001/0x101F) verified absent; 0x130/0x304/0x192 absent. - 0x1D0 b0 coolant drifts up (37->40C, -48 holds); 0x1D0 b1 oil temp = 0xFF. - 0x1D2 gear encoding resolved: DLC 6, byte0 gear codes (E1=P, B4=N, 78=D live). - Corrected LISTEN_ONLY -> NORMAL/ACK across pages; documented non-isolated TJA1051 grounding requirement. Updated index + log. Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -21,3 +21,7 @@ Deep-research workflow ran (interrupted twice by session task-loss on Windows; ~
|
||||
## [2026-07-15] update | Donor and target vehicle confirmed by user
|
||||
|
||||
User confirmed: donor chassis is **E60/E65 (2003+)**, transmission is a **BMW auto with EGS on the CAN bus**, target vehicle is a **Nissan Patrol**. Created [[nissan-patrol-swap]]; updated [[bmw-m57n-engine]] (E46-era candidate IDs flagged as probably wrong generation) and [[open-questions]] (three questions moved to Answered). Next: web research for E60-generation PT-CAN broadcast IDs.
|
||||
|
||||
## [2026-07-16] ingest | First live CAN capture — research map CONFIRMED
|
||||
|
||||
First real dump off the swap's bus, taken with the board's **own new raw-frame logger** (`(repo)`; USB-CDC stream, serial mutex, ~486 frame/s, ~1.4% line loss). Raw filed at `raw/can-capture-2026-07-15-gearshift.csv` (20,596 frames) → [[can-capture-2026-07-15]]. Findings: 15 IDs live incl. **all four researched signal IDs** (0x1D0, 0x1D2, 0x0B5, 0x3B4) + bonus 0x0AA/0x0BA; firmware's placeholder IDs (0x4F/0x55/0x201/0x1001/0x101F) **verified absent**; researched-but-absent: 0x130/0x304/0x192. **0x1D0 b0** drifts 0x55→0x58 (coolant −48, ~37→40 °C); **0x1D0 b1 = 0xFF** (oil temp unpopulated). **0x1D2 gear encoding resolved**: DLC 6, byte0 whole-byte codes (0xE1=P, 0xB4=N, 0x78=D seen live). **0x3B4** at ~5 s rate but payload dormant (0xFF) — engine state unconfirmed. Updated [[can-id-candidates]], [[can-bus-integration]], [[esp32-s3-touch-lcd-5b]], [[open-questions]], index. Also corrected a firmware fact across pages: driver runs **`TWAI_MODE_NORMAL` (ACKs the bus), not LISTEN_ONLY**; TJA1051 is non-isolated → must share vehicle ground. Next: cold-start + confirmed-engine-running capture to lock coolant/battery scaling; use differential (per-position) captures for gear.
|
||||
|
||||
Reference in New Issue