Clarify self-poll needs no session/security; record Diagnostics-screen plan

- capture proof: Launch used only 1A/2C/22/23 - no 10/27/3E. Self-polling a
  2C live value needs just the define + poll, no session or security seed.
  Corrected the earlier "needs session handshake" wording.
- design decision: active polling (if built) lives behind a password-
  protected Diagnostics screen - authorized-tech gate, manual, refuses with
  a scan tool connected, read-oriented services. open-questions #12.
- wiki: launch-capture + obd-diagnostic-polling tightened; project memory
  added so the capability and guard rails are not re-researched later

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
This commit is contained in:
2026-09-23 17:06:20 +02:00
parent 6bdf4d43a9
commit da4c96903b
4 changed files with 23 additions and 5 deletions
+4
View File
@@ -105,3 +105,7 @@ Third session. Added `diag raw on|off` (CANRAW mute) and tools/diag_scan.py (ide
## [2026-09-23] ingest | Launch capture: rail pressure decoded (service 2C)
The capture-with-Launch session, finally run (engine idling, our read-only serial_logger recording CANRAW while the Launch polled the DDE; user selected Rail Pressure actual, blipped to 2500 rpm for a second point). Result: live data on this DDE comes via KWP service 2C (dynamicallyDefineLocalIdentifier), NOT the 22 D1xx identifiers (which do not exist here) and not the session-gated 21 blocks the blind scan hit. Poll 2C 10 00 DF -> reply 6C 10 HHLL. Rail pressure VERIFIED two-point against the Launch display: bar = HHLL x 0.03 (idle raw 0x27EF=307 bar vs ~305 shown; 2500 rpm raw 0x3768=425 bar vs ~430 shown; transient spikes to 0x4E31~600 bar at tip-in). Recipe generalises to any Launch-visible value. Self-polling needs the connect-time session/define handshake (captured, but a transmit-on-the-bus design decision - deferred). Wrote sources/launch-capture-2026-09-23.md; updated obd-diagnostic-polling, open-questions #7, index; raw at serial-COM10-20260923-163511.log.
## [2026-09-23] lint | Clarify self-poll requirements; record Diagnostics-screen plan
Tightened the live-data findings after checking the full capture: the Launch used only 1A/2C/22/23 - NO 10 (session), 27 (security), or 3E (tester-present). So self-polling a 2C value (e.g. rail pressure) needs only the 2C 10 15E0 define + 2C 10 00DF poll, no secret; the earlier 21-block NRCs (0x22/0x33) are a different mechanism and do not gate 2C. Corrected the "needs session/define handshake" wording in launch-capture-2026-09-23.md and obd-diagnostic-polling. Recorded the design decision (user, 2026-09-23): active polling, if built, lives behind a password-protected Diagnostics screen (authorized-tech gate, manual, refuses while scan tool connected, read-oriented services) - open-questions #12, and a project memory so the capability is not re-researched later.