Clarify self-poll needs no session/security; record Diagnostics-screen plan

- capture proof: Launch used only 1A/2C/22/23 - no 10/27/3E. Self-polling a
  2C live value needs just the define + poll, no session or security seed.
  Corrected the earlier "needs session handshake" wording.
- design decision: active polling (if built) lives behind a password-
  protected Diagnostics screen - authorized-tech gate, manual, refuses with
  a scan tool connected, read-oriented services. open-questions #12.
- wiki: launch-capture + obd-diagnostic-polling tightened; project memory
  added so the capability and guard rails are not re-researched later

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
This commit is contained in:
2026-09-23 17:06:20 +02:00
parent 6bdf4d43a9
commit da4c96903b
4 changed files with 23 additions and 5 deletions
+11 -3
View File
@@ -26,14 +26,22 @@ Calibration points (sustained, not transient):
Transient spikes to `0x4E31` (20017 → 600 bar) occurred at the instant of throttle tip-in (rail overshoot); they are real but not the steady value the gauge reads.
## How the Launch reads it — the mechanism `(observed, semantics unverified)`
## How the Launch reads it — the mechanism `(observed 2026-09-23)`
Not the simple `21`/`22` identifier reads the [[diag-route-b-2026-09-23]] blind scan tried (those NRC'd — session/security gated). The live poll is **service `2C`** (KWP dynamicallyDefineLocalIdentifier family): on connect the Launch sends `2C 10 15 E0` once (define), then polls `2C 10 00 DF` repeatedly (~200 ms), each returning a fresh `6C 10 HHLL`. So the value ID `00 DF` is the rail-pressure block. Interpreting `00 DF` / `15 E0` as memory addresses vs block numbers is unconfirmed — for replay only the request bytes matter. The Launch also runs a constant `1A 80` ident keep-alive and did `23` (readMemoryByAddress) reads on connect (ident/programming data, ASCII `"090"` etc.).
The live poll is **service `2C`** (KWP dynamicallyDefineLocalIdentifier family): on connect the Launch sends `2C 10 15 E0` once (define), then polls `2C 10 00 DF` repeatedly (~200 ms), each returning a fresh `6C 10 HHLL`. So the value ID `00 DF` is the rail-pressure block. Interpreting `00 DF` / `15 E0` as memory addresses vs block numbers is unconfirmed — for replay only the request bytes matter. The Launch also runs a constant `1A 80` ident keep-alive and did `22`/`23` (readData / readMemoryByAddress) reads on connect (ident/programming data, ASCII `"090"` etc.).
### Services the Launch used — and did NOT use `(verified from the full capture)`
Every `0x6F1` request in the ~13 MB log, by service: **`1A`** (ident keep-alive), **`2C`** (live-data define/read), **`22`/`23`** (connect-time ident/memory), plus flow control. **Absent entirely: `10` StartDiagnosticSession, `27` SecurityAccess, `3E` TesterPresent.**
This is the key operational finding: **rail pressure is served in the DDE's default state — no diagnostic session, no security seed/key, no tester-present keep-alive.** The earlier `21 xx` NRCs (0x22 conditions-not-correct, 0x33 security-denied) in [[diag-route-b-2026-09-23]] were specific to the `21` read-by-local-id mechanism — a *different door* — and do **not** apply to the `2C` path. There is no secret algorithm between us and this value.
## Consequences
- **The method generalises**: any value the Launch will display can be decoded the same way — capture the `2C`/`6C` pair while its screen shows the number, calibrate scale against the display at two points. Boost, MAF, injection quantity, EGTs are each one session away. See [[obd-diagnostic-polling]] "Beyond the probe".
- **Decode ≠ self-poll.** Replaying `2C 10 00 DF` ourselves needs the connect-time session/define handshake first (`2C 10 15 E0`, and the session the blind `21` scan showed is required). Stepping a running DDE into a diagnostic session is a transmit-on-the-bus **design decision**, not something the read-only probe does today. The bytes to do it are in this log if we choose to.
- **Self-poll is feasible without any secret.** To read rail pressure ourselves: send the one-time define `2C 10 15 E0`, then poll `2C 10 00 DF` → parse `6C 10 HHLL`. **No `10` session, no `27` security, no `3E` tester-present required** (proven above). The only barriers are our own choices, not the ECU's — see the two below.
- **It is still a transmit-on-the-bus action, and `2C` is not strictly read-only** (it writes a definition into the ECU's dynamic-identifier table — harmless, but a state change). So it stays outside the current probe whitelist by policy.
- **Intended home (design decision, 2026-09-23):** any active polling belongs behind a **password-protected "Diagnostics" screen** on Controller A — authorized-technician gate — never a background/automatic poller and never while a scan tool is connected. Records [[open-questions]]; not built yet.
- No EGS traffic (`0x618`) — only the DDE (`0x612`) answered; the Launch was on an engine page.
## Related