Driveline screen: boot into it, add engine torque, revise shaft scaling

Boot screen: land on the Driveline data screen instead of the SquareLine
gauges Home screen. Done in display_init after ui_init while the backlight is
still off (no flash of the wrong screen); Home stays reachable by swiping off
Driveline.

Engine torque added to the screen, decoded from 0x0A8 TORQ_AVL (available/
delivered torque), bits 12-23, signed x0.5 Nm. The user identified the ID and
supplied the spreadsheet formula (D2*256+D1)/32, which is algebraically
bits12-23 x0.5; confirmed against the repo's 0x0A8 worked example (24 Nm).
Firmware masks D1's low nibble (that's the alive counter, not torque - the
repo example shows ALIV=8 there) and sign-extends so overrun reads negative.
0x0AA TORQ_DVCH is the same layout but driver demand - identical at idle,
diverges under load - so the delivered value is the right one to show.

Output-shaft scaling revised: a direct Launch reference (output speed 128 rpm
at our raw 1192) implies ~0.107, contradicting the earlier x0.125 (which would
predict 149). One eyeballed cross-tool point, so nothing is adopted - the
field stays raw counts - but 0.125 is downgraded in firmware and wiki, and the
Launch now gives a direct rpm reference so calibration is just a multi-point
sweep and a linear fit.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
This commit is contained in:
2026-07-17 17:45:00 +02:00
parent 0b31c6f5f7
commit e10e03eb90
11 changed files with 99 additions and 427485 deletions
+22 -3
View File
@@ -114,9 +114,24 @@ A smooth, gently-rising upshift schedule — textbook M57N at light throttle. Fi
The gearbox is a confirmed **6HP26X** (user, 2026-07-17), so the ratio table is right. The one assumption left standing is **max-output-per-gear = upshift point**.
### Finishing it (one capture)
### ⚠ Direct reference reading contradicts ×0.125
Log **`0x1A2` alongside `0x0BA`** at steady speed through the gears. **Turbine ÷ output gives each gear ratio directly** — no assumption about shift points — and simultaneously cross-checks the box identity against the 6HP26 table. `0x0AA` for engine rpm makes it airtight. The 2026-07-17 capture was filtered to `0x0BA`/`0x1D2` only, which is the sole reason this is still open.
The Launch diagnostic tool reads the EGS output speed directly in rpm (it polls the box, so this is the EGS's own value in engineering units). First simultaneous-ish reading (user, 2026-07-17):
| Launch output speed | our raw `0x0BA` D3/D4 | implied factor |
|---|---|---|
| **128 rpm** | **1192** | **0.107** |
`0x125` would predict 1192 × 0.125 = **149 rpm**; the Launch showed **128**. That's 16 % off — too far to be rounding. **So ×0.125 is probably wrong**, and the true factor is nearer **0.107**. This is exactly the failure mode flagged above: the upshift-schedule test couldn't distinguish 0.107 from 0.125 (both produce a plausible-looking curve), so it never really pinned the factor — it only ruled out raw-as-rpm.
> [!warning] One eyeballed point, not a calibration
> Reading 128 on one tool and 1192 on another at the same instant, on a spinning driveline, is hard to do precisely — the two may be a second apart at slightly different speed. So this **downgrades ×0.125** but doesn't yet promote 0.107. It also can't see an offset (both go through zero, which we know, so a pure factor should hold).
### Finishing it (now easier — the Launch IS the reference)
The Launch gives road/output speed directly in rpm, so we no longer need the turbine-ratio inference at all — just **several simultaneous `(raw, Launch-rpm)` pairs across a speed sweep**, then a linear fit. Slope = the factor, intercept should be ~0. Three or four points settle it far better than one.
Still worth logging **`0x1A2` alongside `0x0BA`** in the same capture: turbine ÷ output cross-checks the box identity against the 6HP26 table independently, and `0x0AA` gives engine rpm. The 2026-07-17 drive capture was filtered to `0x0BA`/`0x1D2` only, which is why the ratio method couldn't run.
`docs/6HP26.pdf` in the source repo would confirm the ratios from a document rather than recollection. → [[open-questions]] wishlist.
@@ -149,7 +164,11 @@ The DME publishes its own cruise/ACC regulation state. `0x0AA` `ST_CLCTR_V` (bit
(source: [[e65-reverse-engineering-repo]]. Our capture reads `0x0` on all 3835 frames — pedal untouched, consistent with a stationary idling test. (verified, 2026-07-17))
Also available: **`ANG_ACPD`** (`0x0AA` bits 24–31, ×0.39063 %) — accelerator pedal position, `0x00` unpressed → `0xFF` floored. And **`TORQ_DVCH`** (bits 12–23, signed ×0.5 Nm) — driver-demand torque.
Also available: **`ANG_ACPD`** (`0x0AA` bits 24–31, ×0.39063 %) — accelerator pedal position, `0x00` unpressed → `0xFF` floored.
> [!note] Torque decode — user's spreadsheet formula confirmed
> **Engine torque is on `0x0A8` (`TORQ_AVL`, available/delivered torque)**, bits 12–23, signed ×0.5 Nm — user-identified. `0x0AA` carries `TORQ_DVCH` (driver *demand*) in the same bit layout, so both read ~27 Nm at idle and are indistinguishable there, but they diverge under load; the delivered value (`0x0A8`) is the one to display.
> The user's Excel formula `(D2*256 + D1)/32` is algebraically identical to `bits12-23 × 0.5` — `(D2<<8|D1)/32 == ((D2<<4)|(D1>>4))×0.5`. Verified against the repo's `0x0A8` worked example (`C7 08 03 …` → 24 Nm). **One caveat**: the low nibble of D1 is `ALIV_TORQ_1_DME` (the alive counter) — the repo example literally shows `ALIV`=8 there — not torque, so the full-16-bit read sweeps in ~±0.5 Nm of jitter. The firmware masks it and sign-extends the 12-bit field (so overrun/braking reads negative). ~27–28 Nm at warm idle on our capture. (verified, 2026-07-17)
### Why a PoC is architecturally plausible