feat(backend): capture voltage, current and sample context in meter samples
The charger sends Voltage/Current.Import in every MeterValues frame but we only stored energy/power/SoC. samples now also record voltage_v, current_a and the OCPP context (Sample.Periodic vs Transaction.Begin/End snapshots, which are legitimately all-zero). Existing dbs migrate via ALTER TABLE on open.
This commit is contained in:
@@ -0,0 +1 @@
|
||||
[2,"2901b39c-8ec0-4b2e-9402-ecf19aeda2f9","MeterValues",{"connectorId":1,"transactionId":2,"meterValue":[{"timestamp":"2026-07-12T07:22:13.558Z","sampledValue":[{"value":"0.0","context":"Transaction.Begin","format":"Raw","measurand":"Current.Import","location":"Outlet","unit":"A"},{"value":"405731","context":"Transaction.Begin","format":"Raw","measurand":"Energy.Active.Import.Register","location":"Outlet","unit":"Wh"},{"value":"0","context":"Transaction.Begin","format":"Raw","measurand":"Power.Active.Import","location":"Outlet","unit":"W"},{"value":"0","context":"Transaction.Begin","format":"Raw","measurand":"SoC","location":"Outlet","unit":"Percent"},{"value":"0.0","context":"Transaction.Begin","format":"Raw","measurand":"Voltage","location":"Outlet","unit":"V"}]}]}]
|
||||
Reference in New Issue
Block a user