The charger sends Voltage/Current.Import in every MeterValues frame but
we only stored energy/power/SoC. samples now also record voltage_v,
current_a and the OCPP context (Sample.Periodic vs Transaction.Begin/End
snapshots, which are legitimately all-zero). Existing dbs migrate via
ALTER TABLE on open.
Frontend rewrite (frontend/, replacing backend/static/):
- Vite + TypeScript + React 19, React Router 7, zustand, TanStack Query 5
- dev: vite proxy /api -> :9000; prod: npm run build -> dist/, served by
the backend with SPA fallback
- pages: Control (gun bays w/ scope+readiness-gated start/stop, relays),
History (who/via/gun/when/duration/kWh audit), Cards (pending review,
enrolled, rejected), Users (permission checkbox matrix)
- self-contained: fonts bundled, no CDN; light/dark; reduced-motion safe
Backend:
- learn mode removed: unknown cards are always refused and queued in
pending_cards; admin approves (name + owner + gun restrictions in one
step) or rejects (denied_cards, silent, un-rejectable); pending count
rides /api/status as the notification signal
- sessions record the auth method (card tap vs in-app button) for audit
- GET /api/permissions: grantable-permission catalog driving the UI matrix
- SPA static serving with path-traversal guard; 503 hint when not built
Smoke test: 54 checks incl. approve/reject round-trips over a fake charge
point and method audit assertions.
backend.db (renamed from sessions.db) now holds everything: the sessions
and samples tables plus a settings table with the app-state sections
(users, allowlist, relays, chargers, learn_mode, session_secret) as JSON
blobs. All mutations go through the API/panel and take effect immediately;
there is no config file and no hand-edit-then-restart ambiguity.
- legacy config.json auto-imports into the db on first start (renamed to
config.json.migrated as a backup)
- new admin endpoints: PUT/DELETE /api/relays/{name} (how tinytuya wizard
results are registered now) and PUT /api/chargers/{cp_id} (panel labels)
- BACKEND_DB env override so tests run on an isolated temp database
- smoke test: 45 checks, real db verified untouched
One FastAPI process on port 9000 (the charger's hardcoded URL), replacing
discovering/station.py for production:
- csms.py: OCPP 1.6J handlers ported from the proven discovery code; the
decide() gate now supports per-gun RFID restriction ("connectors": [2])
enforced at StartTransaction
- users.py: username/password auth (PBKDF2), stateless HMAC sessions
(cookie + bearer, 30 days), fnmatch permission scopes
(charger:<cp>:<gun>, relay:<name>, admin) and a user CLI
- relays.py: local tinytuya control of the SmartLife/Tuya WiFi relays
(no cloud; needs one-time id/local-key extraction via tinytuya wizard)
- store.py: SQLite consumption tracking — who charged, when, how many kWh,
per-minute energy/power/SoC samples; tx ids survive restarts
- routes.py: /api/* with per-scope checks, allowlist/user CRUD, runtime
learn-mode flip, session history with visibility rules
- static/: self-contained vanilla-JS PWA — login, per-gun start/stop gated
by scope + gun readiness, relay toggles, history, admin tab
config.json (password hashes, session secret, Tuya keys) and sessions.db
are gitignored; config.example.json documents the shape. Covered by a
37-check smoke test incl. a fake charge point over the real WS route.