--- type: entity updated: 2026-07-09 tags: [hardware, ocpp-client] --- # JC-6620 — OCPP Communication Controller The dedicated OCPP communication controller inside the [[anfu-charger|Anfu charging pile]]. **This is the device that acts as the OCPP client** — it opens the outbound WebSocket to the CSMS. (Per [[2026-07-09-findings-and-requirements]].) ## Network identity - Static IP **`192.168.2.228`**, mask `255.255.255.0`, on the charger's internal LAN (see [[network-topology]]) - Default gateway must be **`192.168.2.1`** (the Four-Faith router) - DNS not needed — the CSMS URL is a bare IP - Talks to the EV charging controller (`192.168.2.118`) locally on port **2403** ## Gotchas specific to this device > [!warning] Shipped misconfigured > The JC-6620 arrived with its default gateway set to `192.168.2.228` — **pointing at itself**. That works for a same-subnet CSMS but cannot route to the WAN, which is why a `192.168.2.x` CSMS worked while a `10.0.10.x` CSMS silently didn't, until the gateway was corrected. (Config screen is in Chinese: 静态 IP = static IP, 默认网关 = default gateway.) - It only dials out at all once the touchscreen's `Billing Mode = BackgroundBilling` is set — see [[troubleshooting]]. - Network/URL changes require a full pile power-cycle to take effect. ## Verified behavior ✅ Connected and completed the full BootNotification exchange against both a LAN CSMS (`192.168.2.114:9000`) and a WAN CSMS (`10.0.10.203:9000`). Since it's the *client*, no port-forwarding is needed on the charger router — NAT handles the outbound connection.