--- type: concept updated: 2026-07-09 tags: [troubleshooting, gotchas] --- # Troubleshooting Checklist Hard-won gotchas from getting the first connection working. **If the charger "never connects," check these in order.** Per [[2026-07-09-findings-and-requirements]]: 1. **CSMS host firewall** — inbound TCP 9000 must be allowed. Windows silently drops otherwise; looks identical to "charger never dials." 2. **`Billing Mode` must be `BackgroundBilling`** — until it is, the [[jc-6620|JC-6620]] never dials out *at all* (zero TCP SYNs on the wire). This was the blocker for the very first connection. 3. **`Communication Method` must be `Ethernet`** — not 4G/SIM. 4. **Power-cycle after changes** — URL / network changes on the [[anfu-charger|touchscreen]] only take effect after power-cycling the pile. 5. **JC-6620 default gateway must be `192.168.2.1`** — it shipped as `192.168.2.228` (itself). Symptom: a same-subnet (`192.168.2.x`) CSMS works but an off-subnet (`10.0.10.x`) one silently doesn't. 6. **No port-forwarding needed** — the JC-6620 is the client and dials outbound; see [[network-topology]]. Don't waste time on the router's forwarding rules. 7. **CSMS host IP must be stable** — the touchscreen URL is hardcoded; a DHCP-shifted host looks like a dead CSMS. Diagnostic ladder (from [[csms-toolkit]]): `rawlisten.py` (do *any* bytes arrive?) → `csms.py` (does OCPP handshake complete?) → `station.py` (full controller).