Files
julian 3326c8d16c docs(wiki): discovery results, architecture, auth model, backend + relay pages
Ingests the 2026-07-09 live session (source page + raw GetConfiguration
dump): charger identified as SimpleCharge MultiSocketCharger, 60 kW DC
dual-standard (gun 1 EU/CCS, gun 2 GB/T); RFID and remote start/stop
verified; by-vehicle auth closed as not supported (three escalating tests
incl. MacEnabled=true after power-cycle); touchscreen-shows-VIN observation
with the DataTransferVendorId long-shot lead.

Adds/updates: architecture plan (FastAPI + PWA, phases 1-3 done), backend
entity, wifi-relays entity (Tuya local-control path + key extraction steps),
authorization concept (API user/scope model, per-gun cards), overview,
runbook, index, log.
2026-07-11 18:58:20 +02:00

3.0 KiB

type, updated, tags
type updated tags
entity 2026-07-09
hardware

Anfu Home Charger (charging pile)

The physical home EV charger this whole project revolves around. Identity per the live probe (2026-07-09-discovery-eu092025): SimpleCharge "MultiSocketCharger", serial 24310588, firmware 1.24.0620.1, OCPP ID eu092025 — with two guns (connectors 1 and 2).

It is not a single device but a small network of three, behind its own Four-Faith router (see network-topology). Per 2026-07-09-findings-and-requirements:

  • jc-6620 (192.168.2.228) — OCPP communication controller; the OCPP client that dials the CSMS
  • EV charging controller (192.168.2.118, DHCP) — the main control board that actually manages charging; the JC-6620 talks to it on port 2403
  • Touchscreen — where all charger-side configuration happens

Touchscreen configuration (working values)

Screen Setting Value
General Settings → Charger INEO URL ws://<CSMS-IP>:9000
General Settings → Charger INEO ChargerID any
Back Office → Universal Billing Mode BackgroundBilling (required — see troubleshooting)
Back Office → Universal Communication Method Ethernet (not 4G/SIM)
Back Office → Universal JC-6620 IP / Port 192.168.2.228 / 2403

[!warning] Power-cycle required URL or network changes only take effect after power-cycling the pile.

Capabilities (per the live probe, 2026-07-09-discovery-eu092025, and the live charging test)

[!warning] Superseded: "basic AC unit" (assumed in 2026-07-09-findings-and-requirements) The first live charging session (2026-07-09) showed gun 2 delivering 30.6 kW at 309.6 V / 98.8 A with SoC reporting — that's DC fast charging, not AC. This is a DC-capable multi-standard charger.

  • ✅ OCPP 1.6J over WebSocket — verified working
  • ✅ DC fast charger, 60 kW (owner-confirmed) with two guns — NumberOfConnectors=2: gun 1 = EU standard (CCS), gun 2 = Chinese standard (GB/T); 30.6 kW observed on gun 2 while both guns charged simultaneously
  • ⚠️ Telemetry quirk: while charging, gun 1's periodic samples read 0 W / 0 V (though SoC updated and energy was delivered — 349 Wh per Transaction.End); gun 2's samples looked sane. Watch whether gun 1 metering is lazy/lagged.
  • ✅ Feature profiles: Core, RemoteTrigger (verified), SmartCharging (Power-based profiles, max 3 periods), Reservation, LocalAuthListManagement (max 6 entries), FirmwareManagement
  • ✅ Meter data every 60 s while charging: Energy, Power, SoC, Voltage, Current
  • ❌ Autocharge / vehicle ID over OCPP — tested and closed 2026-07-09: no idTag ever forwarded, even with MacEnabled=true after a power-cycle (authorization); the charger clearly holds the DC handshake (reports SoC) but firmware 1.24.0620.1 keeps the vehicle identity to itself
  • ❌ True ISO 15118 Plug & Charge — nothing in the config suggests it