julian 56c9020d9f refactor(backend): single SQLite store — config.json eliminated
backend.db (renamed from sessions.db) now holds everything: the sessions
and samples tables plus a settings table with the app-state sections
(users, allowlist, relays, chargers, learn_mode, session_secret) as JSON
blobs. All mutations go through the API/panel and take effect immediately;
there is no config file and no hand-edit-then-restart ambiguity.

- legacy config.json auto-imports into the db on first start (renamed to
  config.json.migrated as a backup)
- new admin endpoints: PUT/DELETE /api/relays/{name} (how tinytuya wizard
  results are registered now) and PUT /api/chargers/{cp_id} (panel labels)
- BACKEND_DB env override so tests run on an isolated temp database
- smoke test: 45 checks, real db verified untouched
2026-07-11 20:15:38 +02:00

2.2 KiB

type, updated, tags
type updated tags
entity 2026-07-11
hardware
relays
tuya

WiFi Relays (SmartLife / Tuya)

Several WiFi relays scattered around the property, currently driven by the SmartLife app (owner report, 2026-07-11). Scope expansion: the backend should control them too, so one self-hosted system runs both the anfu-charger and the relays.

What they are

SmartLife = Tuya's consumer app, so these are Tuya WiFi devices. The "discovered by Bluetooth at first" behavior the owner observed is Tuya's standard BLE-assisted pairing (the phone passes WiFi credentials over BLE once); after provisioning the relays live on WiFi and speak Tuya's local protocol on TCP 6668, which the tinytuya library drives directly — no Tuya cloud in the loop for day-to-day control. SmartLife keeps working in parallel; local and app control don't conflict.

Control path (implemented in backend/relays.py, ⚠️ awaiting keys)

Local control needs each device's id + local key, extracted once via Tuya's own API:

  1. Create a (free) account at iot.tuya.com → Cloud → create a project (data center matching the SmartLife account region).
  2. Link the SmartLife app account to the project (Devices → Link App Account → scan QR in SmartLife).
  3. From the repo root: venv\Scripts\python -m tinytuya wizard — enter the project's API id/secret; it dumps every paired device's id, key, ip, and protocol version.
  4. Register each relay via PUT /api/relays/<name> (admin; interactive form at /docs) with its id, key, ip, version. The Tuya cloud account is never needed again unless a device is re-paired (re-pairing regenerates the local key).

Recommended: DHCP reservations for the relays and pinned "ip" entries in the config — "ip": "auto" works via UDP broadcast discovery but is slower and only finds relays on the same L2 segment as the backend host (❓ verify which subnet the relays are on vs. the future always-on host, see network-topology).

API (see backend)

GET /api/relays?live=true (poll all), GET /api/relays/{name}, POST /api/relays/{name}/on|off|toggle. ⚠️ Untested against the physical relays until the keys are in the config.