2e5960fae3
- Created initial wiki structure with CLAUDE.md schema, index.md, and log.md. - Ingested findings and requirements document into the wiki. - Added concepts for authorization methods, network topology, OCPP protocol, and troubleshooting. - Documented entities including the Anfu charger, JC-6620 controller, and CSMS toolkit. - Established configuration files for Obsidian app settings and workspace layout. - Implemented core plugins and appearance settings for the wiki.
1.5 KiB
1.5 KiB
type, updated, tags
| type | updated | tags | |
|---|---|---|---|
| entity | 2026-07-09 |
|
Anfu Home Charger (charging pile)
The physical home EV charger this whole project revolves around. It is not a single device but a small network of three, behind its own Four-Faith router (see network-topology). Per 2026-07-09-findings-and-requirements:
- jc-6620 (
192.168.2.228) — OCPP communication controller; the OCPP client that dials the CSMS - EV charging controller (
192.168.2.118, DHCP) — the main control board that actually manages charging; the JC-6620 talks to it on port 2403 - Touchscreen — where all charger-side configuration happens
Touchscreen configuration (working values)
| Screen | Setting | Value |
|---|---|---|
| General Settings → Charger INEO | URL | ws://<CSMS-IP>:9000 |
| General Settings → Charger INEO | ChargerID | any |
| Back Office → Universal | Billing Mode | BackgroundBilling (required — see troubleshooting) |
| Back Office → Universal | Communication Method | Ethernet (not 4G/SIM) |
| Back Office → Universal | JC-6620 IP / Port | 192.168.2.228 / 2403 |
[!warning] Power-cycle required URL or network changes only take effect after power-cycling the pile.
Capabilities in question
- ✅ OCPP 1.6J over WebSocket — verified working
- ⚠️ Autocharge (per-vehicle idTag on plug-in) — needs a physical test; see authorization