2e5960fae3
- Created initial wiki structure with CLAUDE.md schema, index.md, and log.md. - Ingested findings and requirements document into the wiki. - Added concepts for authorization methods, network topology, OCPP protocol, and troubleshooting. - Documented entities including the Anfu charger, JC-6620 controller, and CSMS toolkit. - Established configuration files for Obsidian app settings and workspace layout. - Implemented core plugins and appearance settings for the wiki.
1.1 KiB
1.1 KiB
type, updated, tags
| type | updated | tags | |
|---|---|---|---|
| concept | 2026-07-09 |
|
OCPP 1.6J
Open Charge Point Protocol, version 1.6, JSON variant ("J") — the protocol between a charge point and its backend (CSMS, Charging Station Management System). Messages are JSON frames over a WebSocket that the charge point opens toward the CSMS.
How it maps onto this project:
- Charge point / client: the jc-6620 inside the anfu-charger
- CSMS / server: the csms-toolkit scripts, listening on
ws://0.0.0.0:9000/<chargePointId> - Messages in play so far:
BootNotification— ✅ full exchange verified in both LAN and WAN setups (per 2026-07-09-findings-and-requirements)Authorize— carries the idTag thatdecide(id_tag)accepts/rejects; the heart of authorizationRemoteStartTransaction/RemoteStopTransaction— the CSMS-initiated calls the future web panel will use
Because the charge point is always the connecting party, the CSMS needs a reachable, stable address — but the charger network needs no inbound rules (see network-topology).