Files
charging_station/wiki/overview.md
T
julian 56c9020d9f refactor(backend): single SQLite store — config.json eliminated
backend.db (renamed from sessions.db) now holds everything: the sessions
and samples tables plus a settings table with the app-state sections
(users, allowlist, relays, chargers, learn_mode, session_secret) as JSON
blobs. All mutations go through the API/panel and take effect immediately;
there is no config file and no hand-edit-then-restart ambiguity.

- legacy config.json auto-imports into the db on first start (renamed to
  config.json.migrated as a backup)
- new admin endpoints: PUT/DELETE /api/relays/{name} (how tinytuya wizard
  results are registered now) and PUT /api/chargers/{cp_id} (panel labels)
- BACKEND_DB env override so tests run on an isolated temp database
- smoke test: 45 checks, real db verified untouched
2026-07-11 20:15:38 +02:00

5.1 KiB

type, updated, tags
type updated tags
meta 2026-07-11
synthesis

Overview — Anfu Home Charger OCPP Project

Goal: a private, self-hosted ocpp backend (CSMS) for a home EV charger. No billing, no public charging. Authorization via existing RFID cards ✅ and a mobile-friendly web app reached over netbird (by-vehicle ❌ closed — firmware never forwards a vehicle id). Scope expanded 2026-07-11: the same backend also controls the household wifi-relays, locally via tinytuya.

Current state (2026-07-11)

Connectivity: ✅ solved. The jc-6620 controller inside the anfu-charger reliably dials out to the CSMS — verified both on the charger's own LAN (192.168.2.114:9000) and across the NAT boundary on the WAN subnet (10.0.10.203:9000). Getting here required the fixes catalogued in troubleshooting; the network layout is in network-topology.

Software: production backend built (2026-07-11), including the web panel. station.py was ported into the ../backend/ package: one FastAPI process on port 9000 = CSMS WebSocket + /api/* (charger control, allowlist CRUD, runtime learn-mode flip) + wifi-relays on/off/toggle + multi-user auth (username/password, per-resource scopes: gun 1 / gun 2 / per-relay / admin, per-gun-restrictable RFID cards — authorization) + consumption tracking (SQLite: who charged, when, how many kWh, per-minute meter samples) + the PWA control panel at / (login, scope-filtered start/stop buttons, relay toggles, history, admin). Smoke-tested (45 checks incl. a fake charge point over the real WS route); ✅ live charger connects to it since 2026-07-11 evening; ⚠️ panel untested from a real phone. All state lives in one SQLite file (backend.db) — no config file, every change via API/panel takes effect immediately. The csms-toolkit (../discovering/) remains as diagnostic tooling.

Capabilities: ✅ known. The live probe (2026-07-09-discovery-eu092025) identified the pile as SimpleCharge "MultiSocketCharger" (fw 1.24.0620.1, OCPP ID eu092025) with two guns, RemoteTrigger (verified), SmartCharging, Reservation, a 6-entry local auth list, and per-minute meter data including SoC. Only Autocharge remains unknown (physical test pending; MacEnabled is a lead — authorization).

Authorization: 2 of 3 methods ✅ verified live (2026-07-09 test session, both cars plugged, both guns charging simultaneously):

  • RFID ✅ — card …393 tapped → Authorize → real charging session on gun 2 (DC, ~26 kW avg, 1.8 kWh delivered). Card enrolled as "RFID card A".
  • Remote (app path) ✅ — RemoteStart and RemoteStop both Accepted and executed on gun 1; app-remote token enrolled.
  • By vehicle ❌ closed — three escalating tests (plain plug-in, MacEnabled=true live, MacEnabled=true after power-cycle) all negative; this firmware never forwards a vehicle ID over OCPP (authorization).

Hardware surprise: this is a DC-capable multi-standard charger (gun 1 EU, gun 2 Chinese GB/T @ 30 kW), not the assumed basic AC unit — see anfu-charger.

What's next

  1. Cut the live charger over to the backend — ✅ done 2026-07-11 evening: eu092025 connects to python -m backend.main (verified in events.jsonl). Remaining: a card tap + a panel button-push on the live charger.
  2. Create the real users — python -m backend.users add <name> --scopes ... for each household member (the API stays open until the first user exists).
  3. Extract the Tuya local keys (tinytuya wizard — steps in wifi-relays) and register them via PUT /api/relays/<name> → relays become controllable.
  4. Flip learn mode off — both cards + the app token are enrolled; switchable from the panel's Admin tab or POST /api/mode?learn=false, no restart. (Only wait if more cards need tapping.)
  5. Test the panel from a phone — it's built and serving at http://<host>:9000/; verify login, a real button-push start on a ready gun, and add-to-home-screen over netbird.
  6. Resolve the ❓ remote-stop restart question — did the gun-2 session auto-restart from auth cache after RemoteStop, or was the card re-tapped? Affects the app's Stop button UX (authorization).

Open decisions ❓

Decision Options Status
Always-on host for CSMS + app LAN PC · the 10.0.10.203 machine · dedicated box (e.g. Pi on charger LAN, joined to NetBird) open — now also needs subnet reachability to the [[wifi-relays
Web app auth — ✅ resolved 2026-07-11: username+password login with per-resource scopes (gun 1 / gun 2 / per-relay / admin) — see authorization. Bootstrap: create the first admin user via python -m backend.users add
Autocharge / by vehicle — ❌ closed 2026-07-09: not supported by this firmware (authorization)
Host IP stability static IP · DHCP reservation open (required either way — touchscreen URL is hardcoded)

Sources