Ingests the 2026-07-09 live session (source page + raw GetConfiguration dump): charger identified as SimpleCharge MultiSocketCharger, 60 kW DC dual-standard (gun 1 EU/CCS, gun 2 GB/T); RFID and remote start/stop verified; by-vehicle auth closed as not supported (three escalating tests incl. MacEnabled=true after power-cycle); touchscreen-shows-VIN observation with the DataTransferVendorId long-shot lead. Adds/updates: architecture plan (FastAPI + PWA, phases 1-3 done), backend entity, wifi-relays entity (Tuya local-control path + key extraction steps), authorization concept (API user/scope model, per-gun cards), overview, runbook, index, log.
3.0 KiB
type, updated, tags
| type | updated | tags | |
|---|---|---|---|
| entity | 2026-07-09 |
|
Anfu Home Charger (charging pile)
The physical home EV charger this whole project revolves around. Identity per the live probe (2026-07-09-discovery-eu092025): SimpleCharge "MultiSocketCharger", serial 24310588, firmware 1.24.0620.1, OCPP ID eu092025 — with two guns (connectors 1 and 2).
It is not a single device but a small network of three, behind its own Four-Faith router (see network-topology). Per 2026-07-09-findings-and-requirements:
- jc-6620 (
192.168.2.228) — OCPP communication controller; the OCPP client that dials the CSMS - EV charging controller (
192.168.2.118, DHCP) — the main control board that actually manages charging; the JC-6620 talks to it on port 2403 - Touchscreen — where all charger-side configuration happens
Touchscreen configuration (working values)
| Screen | Setting | Value |
|---|---|---|
| General Settings → Charger INEO | URL | ws://<CSMS-IP>:9000 |
| General Settings → Charger INEO | ChargerID | any |
| Back Office → Universal | Billing Mode | BackgroundBilling (required — see troubleshooting) |
| Back Office → Universal | Communication Method | Ethernet (not 4G/SIM) |
| Back Office → Universal | JC-6620 IP / Port | 192.168.2.228 / 2403 |
[!warning] Power-cycle required URL or network changes only take effect after power-cycling the pile.
Capabilities (per the live probe, 2026-07-09-discovery-eu092025, and the live charging test)
[!warning] Superseded: "basic AC unit" (assumed in 2026-07-09-findings-and-requirements) The first live charging session (2026-07-09) showed gun 2 delivering 30.6 kW at 309.6 V / 98.8 A with SoC reporting — that's DC fast charging, not AC. This is a DC-capable multi-standard charger.
- ✅ OCPP 1.6J over WebSocket — verified working
- ✅ DC fast charger, 60 kW (owner-confirmed) with two guns —
NumberOfConnectors=2: gun 1 = EU standard (CCS), gun 2 = Chinese standard (GB/T); 30.6 kW observed on gun 2 while both guns charged simultaneously - ⚠️ Telemetry quirk: while charging, gun 1's periodic samples read 0 W / 0 V (though SoC updated and energy was delivered — 349 Wh per Transaction.End); gun 2's samples looked sane. Watch whether gun 1 metering is lazy/lagged.
- ✅ Feature profiles: Core, RemoteTrigger (verified), SmartCharging (Power-based profiles, max 3 periods), Reservation, LocalAuthListManagement (max 6 entries), FirmwareManagement
- ✅ Meter data every 60 s while charging: Energy, Power, SoC, Voltage, Current
- ❌ Autocharge / vehicle ID over OCPP — tested and closed 2026-07-09: no idTag ever forwarded, even with
MacEnabled=trueafter a power-cycle (authorization); the charger clearly holds the DC handshake (reports SoC) but firmware1.24.0620.1keeps the vehicle identity to itself - ❌ True ISO 15118 Plug & Charge — nothing in the config suggests it