julian 3326c8d16c docs(wiki): discovery results, architecture, auth model, backend + relay pages
Ingests the 2026-07-09 live session (source page + raw GetConfiguration
dump): charger identified as SimpleCharge MultiSocketCharger, 60 kW DC
dual-standard (gun 1 EU/CCS, gun 2 GB/T); RFID and remote start/stop
verified; by-vehicle auth closed as not supported (three escalating tests
incl. MacEnabled=true after power-cycle); touchscreen-shows-VIN observation
with the DataTransferVendorId long-shot lead.

Adds/updates: architecture plan (FastAPI + PWA, phases 1-3 done), backend
entity, wifi-relays entity (Tuya local-control path + key extraction steps),
authorization concept (API user/scope model, per-gun cards), overview,
runbook, index, log.
2026-07-11 18:58:20 +02:00

3.3 KiB

type, updated, ingested, raw, tags
type updated ingested raw tags
source 2026-07-09 2026-07-09 raw/discovery_eu092025.json
discovery
capabilities
ocpp

Discovery Probe — Live Capability Dump from "eu092025"

Raw source: discovery_eu092025.json — the answer the real charger gave to GetConfiguration (all keys) + TriggerMessage, captured live on 2026-07-09 by the new auto-interrogation in csms-toolkit. This replaces guesswork with the charger's own capability sheet.

TL;DR

The pile identifies as SimpleCharge "MultiSocketCharger", serial 24310588, firmware 1.24.0620.1, OCPP charge-point ID eu092025, and it has two guns (NumberOfConnectors=2; connectors 1 and 2, plus 0 = the whole unit — all reported "Available"). It supports far more than we assumed: RemoteTrigger ✅ (verified), SmartCharging, Reservation, LocalAuthListManagement, FirmwareManagement.

Key configuration facts

Key Value Meaning for us
NumberOfConnectors 2 Two guns — the app/UI must be per-connector, not per-charger
SupportedFeatureProfiles Core, FirmwareManagement, LocalAuthListManagement, Reservation, SmartCharging, RemoteTrigger RemoteTrigger already verified working ✅
AuthorizeRemoteTxRequests false Remote starts skip a separate Authorize — our decide() gate still fires at StartTransaction (authorization)
LocalAuthListMaxLength 6 On-charger offline allowlist holds only 6 idTags — enough for a household
LocalAuthListEnabled / LocalAuthorizeOffline false / false Offline auth currently off; charger is fully CSMS-dependent when offline
MeterValueSampleInterval 60 s Live data every minute during charging
MeterValuesSampledData Energy, Power, SoC, Voltage, Current Rich live telemetry — even state-of-charge — for the web panel
HeartbeatInterval / WebSocketPingInterval 7200 s / 60 s Liveness comes from WS pings, not heartbeats
ConnectionTimeOut 60 s A remote start waits 60 s for a plug-in before expiring
MacEnabled false ❓ Suggestive lead for [[authorization
FreeChargeMode false Exists — a "just charge, no auth" escape hatch if we ever want it
Url http://10.0.10.203:9000 Confirms this PC is the configured CSMS host
Pricing keys (PeakPrice, IdleFeePerMinute, …) set Vendor billing leftovers; irrelevant for private use

Also present: QRCodeTextOfConnector-1..3 (writable, empty), ChargingScheduleAllowedChargingRateUnit=Power with max 3 schedule periods and 1 installed profile (SmartCharging is real but small), ReserveConnectorZeroSupported=false.

Boot identity (via TriggerMessage(BootNotification))

vendor=SimpleCharge, model=MultiSocketCharger, serial=24310588, firmware=1.24.0620.1 — note GetConfiguration reports Vendor=JC (the jc-6620 module vendor) while BootNotification says SimpleCharge (the charger brand).

Wiki changes from this ingest

Updated anfu-charger (identity + capabilities), authorization (remote-auth behavior, LocalAuthList, MacEnabled lead), csms-toolkit (discovery API), overview.