**Ask (operator, 2026-10-08):** write down how we will give every known device class — relays,
printers, cameras, readers — a **Scan** in the setup wizard, the way the DT-008 reader got one
today. This memo is the plan: what exists, the method that worked, what each device can
actually answer on the wire (probed on the lab VLAN today where possible), the rules that carry
over, and the order to build in. Nothing here is built except the reader.
## 1. Why discovery is worth building (the park-2 lesson)
[[first-run-setup]] has the admin **type** what a device is — IP, serial, port. Nothing checked
that the typed picture matched the device. park-2 ran a month with two readers whose typed
config was perfect and whose *actual* output mode was Wiegand: every card "beeped" and none
reached the booth ([[site-device-installation]] §2 trap). Discovery is the reality check that
replaces typing with **what the device says about itself**, and — the part that matters more —
its companion **identity precondition**: *the serial/MAC you typed is the one the device at
that IP reports*. The same mechanism ends the Windows-tool-on-a-laptop site visits (SADP for
cameras, the Dingtian tools, printer utilities): one laptop-free wizard on the booth.
## 2. What already exists (don't rebuild)
- `DiscoverableDriver.discover() → DiscoveredDevice[]` in `@parking/devices` (`id`, `label`,
`config` to auto-fill, free-form `info`), the registry's `isDiscoverable()`, the catalog's
`discoverable` list, admin-only `GET /api/setup/discover/:driverId` (health-checks each hit),
and the wizard's **Scan** button + **Use** per row, rendering every `info` key
([[device-discovery]]).
- The write side that discovery feeds: `PreconditionDevice` (check → fixable/unfixable issues,
shown on **Test**, fixed on **Save**), `PushConfigurableDevice` (point the device at this
booth), `HardenableDevice`. The DT-008 driver is the worked example of all three together.
- Already a discovery in all but name: `GET /api/setup/usb-printers` lists `/dev/usb/lpN` with
the printer's self-reported make/model from sysfs `ieee1284_id` ([[printer-usb-transport]]).
## 3. The method that worked for the DT-008 (reuse it verbatim)
1. **Learn the protocol on the bench, never on a site.** Vendor tool + a lab unit; capture the
tool's own datagrams or read the vendor doc. Write it up as `raw/<device>/PROTOCOL.md`
(frame, ports, commands, field tables, *verification status per command*).
2. **TypeScript module + fake-device tests** (`drivers/<device>-config.ts`, `*.test.ts` with a
loopback fake that enforces the protocol's quirks — e.g. the DT-008's two-datagram writes).
3. **Driver hooks:** `discover()` (search → per-hit identity read → `config` + `info`),
`checkPreconditions()` (identity match + the one or two settings our flow depends on),
`fixPreconditions()` / `configureInputPush()` only for settings proven writable.
4. **Bench round trip with restore**: change → read back → change back → byte-diff the device's
config. Only then touch a site, and there only through the wizard.
5. Wiki: entity page, [[device-discovery]], [[first-run-setup]], the install runbook, log.
## 4. Per device: what answers on the wire
Status legend: **verified** = we saw it on the lab VLAN today (host `10.0.10.203`);
**documented** = vendor doc / wiki says so, not yet seen; **unknown** = needs a capture.
| device | mechanism | transport | returns | status |
| --- | --- | --- | --- | --- |
| DT-008 reader | vendor search cmd 2 | UDP bcast 24582 | serial, IP, server:port | **verified, built** |
| Hikvision cameras / DVR | **SADP** Probe | UDP mcast `239.255.255.250:37020`, XML | model, **serial**, **MAC**, IPv4, HTTP + command port, (activation state) | **verified**: 9 devices answered |
| Hikvision, Dahua, any IP camera | **ONVIF WS-Discovery** Probe | UDP mcast `239.255.255.250:3702`, SOAP | `XAddrs` (device-service URL), scopes: hardware model, name, sometimes MAC | **verified** on 4 Hikvision; the bench Dahua did **not** answer (see 4.2) |
| Dahua cameras | ConfigTool search ("DHIP") | UDP bcast 37810 | (per vendor tool: IP, MAC, serial, model) | **unknown** — my guessed frame got no reply; capture the ConfigTool like the DT-008 exe |
| Dingtian relay | search | UDP mcast `224.0.2.11:60000`, payload `05 AA` | "devices reply" ([[dingtian-relay]]) — reply content not recorded | **documented**; no relay on the lab VLAN to probe |
| Rongta / K200L LAN printers | no vendor discovery known to us | — | — | **unknown** (vendor utilities exist; protocol uncaptured) |
| any network ESC/POS printer | **TCP 9100 sweep** of the device subnet + web fingerprint | TCP connect ×254 in parallel, then HTTP GET | IP; model only via the board's web page | **verified**: 2 hits (`.220`, `.234`) in ~1 s — both *office* printers, neither ours → fingerprint is mandatory |
| USB printers | `/dev/usb/lpN` + `ieee1284_id` | sysfs | path, MFG/MDL | **built** |
### 4.1 Cameras — two protocols, run both, merge by MAC/serial
- **SADP** is the one that finds *everything Hikvision*, including units whose ONVIF is off
(5 of today's 9 answered SADP only) and **unactivated** units (factory `192.168.1.64`,
`<Activated>false</Activated>`) — i.e. the exact state a new G3H arrives in. Its ProbeMatch
carries `DeviceDescription` (model), `DeviceSN`, `MAC`, `IPv4Address`, `HttpPort`,
`CommandPort` (8000). Newer firmware (the DVR today) adds `<Encrypt>true</Encrypt><Salt>…`
for its *write* side; the inquiry itself stays plaintext. SADP can also **activate** a camera
and **set its IP** (password-protected) — the runbook's "activate with SADP or the browser"
step ([[site-device-installation]] §3) could become a wizard action later; discovery first.
- **WS-Discovery** is the vendor-neutral path and the only standard one Dahua offers. Scopes
give the model (`onvif://www.onvif.org/hardware/DS-2CD2T43G0-I5`) and `XAddrs` gives the
device-service URL — enough to pick the driver (`DS-…` → `hikvision`, Dahua names → `dahua`)
and the IP. **Caveat seen today:** the bench IPC-HFW2549T answered neither WS-Discovery nor
my 37810 guess; Dahua ships ONVIF switchable (web UI → Network → *Integration Protocol* /
ONVIF) — check that unit's setting before concluding anything. Record the outcome on
[[dahua-ipc-hfw2549t]].
- **Identity precondition for cameras:** on Use, store `serial` (SADP `DeviceSN` / ONVIF
scope) + `mac` next to `host`; on Test/Save compare with what the camera reports over its own
API (Hikvision `/ISAPI/System/deviceInfo` → `serialNumber`; Dahua
`magicBox.cgi?action=getSerialNo`). A swapped or re-addressed camera then fails loudly instead
of silently snapshotting the wrong lane. Further preconditions the same hook can own, all from
past incidents: clock drift ([[lpr-camera]] clock sync), ANPR push target = this booth
([[lpr-camera]] §Camera PUSH — Alarm Server), vehicle target filter on.
- Shape: keep the per-driver API; `hikvisionDriver.discover()` = SADP ∪ ONVIF filtered to
Hikvision hardware, `dahuaDriver.discover()` = ONVIF filtered ∪ (37810 once captured). Merge by
MAC, then serial; never by IP.
### 4.2 Dingtian relay — documented, unprobed
[[dingtian-relay]] records the vendor's search: multicast `224.0.2.11:60000`, payload `05 AA`,
devices reply; defaults IP `192.168.1.100`, UDP 60000 binary / 60001 string. Open before
building: (a) what the reply contains (MAC? firmware? — needed for identity; our relay config
has no serial today, identity is the IP alone); (b) whether a **hardened** board (relay_pw set,
string protocol disabled — [[dingtian-relay]] §hardening) still answers an unauthenticated
search — if not, discovery only finds *new* boards, which is still the useful case; (c) whether
the reply can come back on the host network from a multicast group (needs
`IP_ADD_MEMBERSHIP` on the device-VLAN interface, or the board may answer by unicast to the
sender — capture to know). Needs a board on the bench; one visit of the vendor tool with the
same capture method as the DT-008.
### 4.3 Printers — sweep + fingerprint, not a vendor protocol
Neither the Rongta board nor the K200L's "J-Speed" LAN module has a discovery protocol we know;
both vendors ship Windows utilities that surely broadcast something, uncaptured. The pragmatic
mechanism is already verified: **connect to TCP 9100 on every address of the device subnet in
parallel** (254 probes, ~1 s), then **fingerprint each hit over HTTP**: Rongta answers
`GET /prn_stat.htm` with its status page ([[rongta-printer]]); the K200L web configurator is a
three-frame page titled "Ethernet WebConfig" ([[k200l-printer]]); anything else is listed as
"unknown 9100 device" (today's two office printers would be). Identity: the K200L *Information*
frame shows its MAC; Rongta's pages carry none we know — fall back to the ARP entry after the
connect (`/proc/net/arp` on the host network). No ESC/POS serial exists over 9100, so the
precondition is weaker here: "a Rongta/K200L board still answers at this IP" plus the live
status page. Preconditions worth owning: USB path still present (already in the USB select),
network board reachable, paper/cover state ([[printer-status-monitoring]]).
### 4.4 DT-008 reader — built; two gaps
Discovery, identity (serial), output mode and push target are done. Still manual: giving a
factory `192.168.1.99` unit its site IP (cmd 32 `set-network` supports it — a "Set IP" action
in the discovery row would finish the laptop-free install), and prefixes / card format (cmds
12/14/44/8). Both are in `scripts/dingtian_qr.py` today ([[dingtian-qr-linux-tool]]).
## 5. Rules that carry over to every implementation
1. **Subnet-directed broadcast per interface**, never `255.255.255.255` (EACCES on some
hosts, and not what vendor tools send); **multicast needs `IP_MULTICAST_IF` per interface**
and, to *receive* group traffic, `IP_ADD_MEMBERSHIP` — SADP/ONVIF replied by unicast to the
sender today, so sending was enough; don't assume that for the relay.
2. **Replies arrive from arbitrary source ports** — match on content, not port; collect for a
window (~2 s), then stop.
3. **Dedupe and identify by a stable identity (serial, MAC) — never by IP**; the IP is the thing
most likely to be wrong.
4. **Discovery is read-only.** "Use" fills the form; writes happen only on Save, through
preconditions/push-config, each proven on the bench with a restore. Discovery must never be
periodic/background: it is an admin action in Setup, so the booth operator (our adversary,
[[threat-model]]) has no new lever.
5. **L2 only.** Works from the booth (host-network server) and the device VLAN; impossible
from a bridged dev container and across Netbird — say so in the empty-result message
(the wizard's "no devices found" text already does).
6. **Replies are untrusted input** from an unauthenticated network: cap sizes, parse XML
without entity expansion, never pass a reply string into a shell/URL unescaped, never
forward credentials to a discovered address without the identity check.
7. **Serials and MACs are site data** — they go in the device row, not in commits/wiki with
booth names ([[fleet-deployment-komodo]] pseudonymity rule).
## 6. Order of work
1. **Cameras — SADP + WS-Discovery** (protocols verified today; no bench captures needed;
biggest field pain = activation/IP of new units; two vendors covered). Half a day plus the
identity precondition.
2. **Printers — 9100 sweep + fingerprint** (verified mechanism, small code, replaces guessing
the printer's IP at park-buzi-type installs).
3. **Dingtian relay search** — when a board is on the bench; capture the reply first.
4. **Dahua 37810** — capture the ConfigTool; until then Dahua relies on ONVIF being enabled.
5. **DT-008 "Set IP" from the discovery row** (set-network is proven).
## 7. Open questions
- Does a hardened Dingtian board answer the `05 AA` search? What is in the reply?
- Is ONVIF off on the bench Dahua, or did the probe not reach it? (web UI check, then re-probe)
- SADP `Encrypt/Salt` on newer firmware: inquiry stays plaintext — confirm on a 2026 unit.
- Rongta board MAC/identity: any page or ESC/POS query that returns a stable id?
- Should the camera row offer **activate + set IP** (SADP write side), or stay read-only and
leave activation to the browser? (Leaning read-only first; writes only after a bench round trip.)
Related: [[device-discovery]] · [[device-registry]] · [[first-run-setup]] ·
[[site-device-installation]] · [[dingtian-dt008-reader]] · [[dingtian-relay]] · [[lpr-camera]] ·
[[dahua-ipc-hfw2549t]] · [[rongta-printer]] · [[k200l-printer]] · [[dingtian-qr-linux-tool]]