fix(devices): Dahua snapshot channel is 1-based; add Dahua clock sync; wiki page for the bench IPC-HFW2549T
Build & push images / images (push) Successful in 3m25s
Build & push images / images (push) Successful in 3m25s
The dahua driver decremented the wizard's channel on the belief the CGI is 0-based. On real hardware (IPC-HFW2549T-AS-IL, fw V2.880, 2026-09-17) snapshot.cgi?channel=0 answers HTTP 400 and channel=1 returns the 2880x1620 JPEG — so every Dahua assignment sat at degraded "HTTP 400". The channel is now sent as entered (clamped >= 1) and the URL is pinned in camera.test.ts. DahuaCamera.syncClock reads global.cgi getCurrentTime and, past the drift limit, writes setCurrentTime with the host's naive local wall time (no offset): the OSD burned into snapshots must match the booth clock; the camera's tz/DST config is left alone. Verified live: a 2h-off set, set back, 1s drift -> no write. The device monitor picks it up via isClockSyncable unchanged. Wiki: new entities/dahua-ipc-hfw2549t.md (endpoint table, verbatim eventManager attach parts — VideoMotion Start/Stop, VideoMotionInfo, TimeChange — RealUTC is the camera's belief of UTC, 5-strike login lockout, unit not factory-fresh); lpr-camera Dahua bullet corrected; runbook §3 Dahua paragraph; index + log. The server-side attach-stream subscriber is not built.
This commit is contained in:
@@ -188,6 +188,18 @@ database → **factory reset**, then redo 1–3 (the Vehicle target filter defau
|
||||
Point the Alarm Server at a dumb HTTP sink on the laptop if you need to see the verbatim body
|
||||
([[lpr-camera]] §"auto-enter but not auto-exit").
|
||||
|
||||
**If the camera is a Dahua** (first unit inspected 2026-09-17, [[dahua-ipc-hfw2549t]]): factory
|
||||
`192.168.1.108`, `admin` + a password set at first boot, web UI on port 80 (HTTPS off by default
|
||||
on the bench unit). In the wizard: driver `dahua`, host, `admin` password, **channel 1 as printed** (the
|
||||
driver sent `channel=0` → HTTP 400 until 2026-09-17; fixed). There is no HTTP Alarm Server to
|
||||
point at the booth: events would be read by the server holding an `eventManager.cgi?action=attach`
|
||||
stream (**not built yet** — a Dahua today gives snapshots + clock sync only, no lane busy/free
|
||||
and no ANPR bridge), so no "assign first, then go back to the camera" step — but SMD must be set
|
||||
to **Vehicle** on the camera. Set the time zone by hand; the app re-syncs the clock from the
|
||||
booth like it does for Hikvision (the bench unit ran 1 h behind with DST off; NTP is useless on
|
||||
the isolated VLAN). Five wrong logins lock `admin` for 5 minutes — check the password with one
|
||||
`curl --digest` before assigning.
|
||||
|
||||
## 4. Radar (vehicle presence at the entry barrier)
|
||||
|
||||
A dry-contact sensor into a Dingtian input, nothing on the network. Check with the board's input
|
||||
|
||||