wiki: zone PoC shut down on park-lab; barrier on the staff remote only
Build & push images / images (push) Successful in 4m55s

The user's rule from 2026-11-22: the system is not ready to control the
barrier yet. Container zg2 is stopped, relays read off beforehand; notes how
to bring it back.

Co-Authored-By: Claude Fable 5.2 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01RZgP5oZdzvo92Eouc9eRv5
This commit is contained in:
2026-11-22 18:34:12 +01:00
parent 726dd9803a
commit 494c11ddbf
3 changed files with 18 additions and 5 deletions
+6 -3
View File
@@ -162,9 +162,12 @@ Nothing in the software removes flare from a wet lens. None of these has been tr
(65 checks) and `replay_recordings.py` (48 recorded visits) run with no camera, model or relay.
The detector model (`yolox_tiny.onnx`, 20 MB) is not in the repository; it lies beside the code
on park-lab.
- **On park-lab:** container `zg2`, page on port 8094, files in `~/zone-anpr-gpu`. It runs the
committed `zone_anpr.py` with `close_live` and `close_on_lost` on, and starts disarmed. Earlier
versions are kept beside it as `zone_anpr.py.bak-20261122-*`.
- **On park-lab:** container `zg2`, page on port 8094, files in `~/zone-anpr-gpu`. **It is stopped
since the evening of 2026-11-22** (user: the barrier is operated only with the staff's remote
control until the system is ready to control it). `docker start zg2` brings it back with the
committed `zone_anpr.py`, `close_live` and `close_on_lost` on, and the relays disarmed. Do not
start it during business hours without the user's word. Earlier versions are kept beside it as
`zone_anpr.py.bak-20261122-*`.
- **Records there:** `out/visits.jsonl`, `out/relays.jsonl`, `out/reads.jsonl`,
`out/reads-all.jsonl`, and per visit `out/clips/<start>_<camera>/` with every processed frame,
its box, and the kept stills with their reads.