docs(wiki): DT-008 card-technology findings, box leaflet source, install checklist; add scripts/reader-sink.py

Two DT-008 units read disjoint card sets (park-buzi 125 kHz, lab unit 13.56 MHz only)
although the box leaflet claims EM-ID + M1 + ISO 14443A/B + 15693 in one unit; recorded as
unresolved with the EM4100 test that settles it (open question #18). Phone taps give a
random 08… UID per tap, so phones are never RF credentials; 6H keeps the first three UID
bytes reversed. Runbook §2 gains the tool's Setting-tab layout, a capability-identification
checklist and the per-technology parameter table. reader-sink.py is a stdlib bench sink
answering the push with the SDK verdict and Connection: close.

Claude-Session: https://claude.ai/code/session_01FWncR69HgGPuei1dLrW3cU
This commit is contained in:
2026-09-17 09:47:40 +02:00
parent 5afdcc78ae
commit 4d1d245680
7 changed files with 290 additions and 5 deletions
+47 -1
View File
@@ -112,6 +112,49 @@ and only after the server's reply (no reply = no beep, the scan still happened).
**Trap:** a factory reset or a swapped unit silently loses items 3–5. Re-apply all of them.
**Trap (2026-09-17): two DT-008 units read disjoint card sets.** park-buzi's units (`H05M…`)
read the site's 125 kHz cards and the fresh lab unit (`HC002721`) reads only 13.56 MHz cards,
although the box leaflet claims both. Batch variant, a dead 125 kHz front end, or a non-EM 125 kHz
card format — unresolved. Rule until it is: **test a replacement reader against the site's actual
cards before it ships**, and record the site's card technology. Quick sort of a card: an NFC phone
detects 13.56 MHz, cannot see 125 kHz. Details: [[dingtian-dt008-reader]] §"Two units, two card
sets".
**Identify what a reader can read — before it ships (2026-09-17).** Keep a **reference kit** in the
lab: one known EM4100 125 kHz fob, one known Mifare Classic (M1) card, and a phone with NFC. Tap all
three on the unit with the tool's log pane open (or [[dingtian-dt008-reader]] §Bench sink): a line
per tap = that technology decodes. The phone always beeps on a 13.56 MHz unit with a random `08…`
id (never a credential, but proves the 13.56 MHz radio). Then tap **the site's own cards**. Write
the result on the site record next to the serial (`reads: EM4100 | M1 | both`). Serial families are
only a hint (`H05M…` read park-buzi's 125 kHz cards, `HC…` did not); the vendor can confirm from a
serial. A unit that fails the site's cards does not leave the lab.
**Parameters per card technology** — identical except one field:
| | 125 kHz site (park-buzi today) | 13.56 MHz site |
| --- | --- | --- |
| Card Input format | **`6H`** (what park-buzi's cards are enrolled with — never change on a live site) | **`8H`** preferred: the native UID is 4 bytes, `6H` drops one and two cards can collide — confirm `8H` on the lab unit before the first enrolment ([[open-questions]] #18) |
| Output prefixes | `Q:` / `K:` | `Q:` / `K:` |
| Output type / server | HTTP, booth IP, booth HTTP port | same |
| Buzzer | On (the operator hears accept/refuse) | On |
| Symbologies | QR + Code128 only | same |
| Card stock | EM4100 (or whatever the reference test showed) — do not mix | Mifare Classic UID-based; note that a phone is never a card |
A site is one technology: once cards are enrolled the reader batch, the input format and the
card stock are frozen together. Migrating means re-enrolling every credential.
**The tool's Setting tab (v1.6.5, seen 2026-09-17):** *Search device* lists units by serial; *Get
parameter* loads one. *Network parameter*: IP / Netmask / Gateway / DNS1 / DNS2, DHCP (Static IP),
**Server address / Server Port / HTTP Server Language**, its own *Set* button. *Format parameter*:
Output type `HTTP`, **Card Input format** (`6H`), QRCode Output format/prefix/suffix, **Card Output
format/prefix/suffix** (prefix fields are where `Q:` / `K:` go), serial baud/bits greyed out under
HTTP, Low/High Pulse, its own *Set*. *External parameter*: Restart interval (12 h), Work mode
(Normal), **Buzzer On/Off**, Scan code fill light, its own *Set*. Each group is written by **its own
Set button** — setting the network and forgetting the format *Set* is easy. The log pane at the bottom
echoes every card read by the tool (`… A238BC`), which is the quickest "did the radio see it" check.
The *Test device* tab is the read monitor. Symbology selection was not found on this tab — locate it
on the *Test device* tab or in a newer tool before relying on item 5.
## 3. Hikvision camera (DS-2CD1047G3H-LIU, AcuSense) — ANPR + snapshots
**Factory:** `192.168.1.64`, **inactive** until a password is set on first boot (browser at that
@@ -197,7 +240,10 @@ barcode with a real ticket (the KP-300H garbled overflowing barcodes until the g
- Factory address and configuration tool of the **Cashino KP-300H** and the **Rongta RP** units
(both still unknown here).
- The exact screens in `QRCode_v1_6_5.exe` for the reader's IP and server target (a screenshot).
- Where in `QRCode_v1_6_5.exe` the **symbologies** are selected (the Setting tab has no such field;
the IP / server / prefix fields are now described in §2).
- The **card technology** each site uses and which reader batch reads it, on the site record next to
the serial; and the result of the EM4100 test on the lab unit.
- Whether the camera activation was done with SADP or the browser at park-buzi, and the per-site
camera password location.
- Where the **site record** lives (a page per site under `wiki/entities/`? — park-buzi and park-2