wiki: ZKTeco CMP200 barrier page, close-input wiring; park-lab reinstall gotchas
- entities/zkteco-cmp200-barrier: terminal map from the CMP200 manuals, board photo findings (v1.2 layout, RS485 socket empty), relay-contact drive from the Dingtian, interlocked close relay, limit outputs as status inputs - concepts/passage-confirmation: barrier model open question answered for the unit on hand - decisions/appliance-provisioning: Komodo gotchas 14-16 from the park-lab reinstall (2026-11-13) - index and log entries Co-Authored-By: Claude Fable 5.2 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01RZgP5ofaSqgLGHMGSL3xYN
This commit is contained in:
@@ -110,7 +110,9 @@ credentials. Nothing of park-lab's device registry has a camera yet (only the re
|
||||
- Window cap and "lane clear" dwell before a close (start: cap 60 s, dwell 3 s).
|
||||
- Does the DS-2CD1043G2-LIU keep pushing VMD for a car *reversing*? (It should — motion is motion.)
|
||||
- Stream-to-event latency and frame drop rate on the booth PC (measure, don't assume).
|
||||
- Which barrier operator model is at the sites, and does park-lab have one for steps 1–6?
|
||||
- Which barrier operator model is at the sites? The unit on hand is a [[zkteco-cmp200-barrier]]:
|
||||
its close input is `DOWN` (dry contact to `G`), and the manual says `DET`/`PHO` reverse a falling
|
||||
boom — steps 1–3 can be run on it.
|
||||
|
||||
Related: [[lane-presence-and-anpr-entry]], [[barrier-not-a-door]], [[entry-double-press]],
|
||||
[[append-only-event-chain]], [[opencv-anpr-service]], [[park-2-event-loop-stall]].
|
||||
|
||||