wiki: ZKTeco CMP200 barrier page, close-input wiring; park-lab reinstall gotchas

- entities/zkteco-cmp200-barrier: terminal map from the CMP200 manuals, board
  photo findings (v1.2 layout, RS485 socket empty), relay-contact drive from
  the Dingtian, interlocked close relay, limit outputs as status inputs
- concepts/passage-confirmation: barrier model open question answered for the
  unit on hand
- decisions/appliance-provisioning: Komodo gotchas 14-16 from the park-lab
  reinstall (2026-11-13)
- index and log entries

Co-Authored-By: Claude Fable 5.2 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01RZgP5ofaSqgLGHMGSL3xYN
This commit is contained in:
2026-11-14 11:08:36 +01:00
parent 13ba593b69
commit 8b1f851add
5 changed files with 146 additions and 1 deletions
+95
View File
@@ -0,0 +1,95 @@
---
type: entity
tags: [parking, hardware, barrier, relay, wiring]
sources: []
updated: 2026-11-14
---
# ZKTeco CMP200 Barrier Gate
The boom barrier on hand. Its mainboard (silkscreen on our unit: `TT-DZ-200504E-A1`) drives an
**AC capacitor-start motor** through on-board relays; limits are Hall switches. Mains 110/220 V AC,
100 W rated. Not to be confused with the [[zkteco-controller]] (access panel, rejected).
Web research 2026-11-14. Sources: ZKTeco CMP200 user manual v1.0 (2019) and v1.2 (March 2022),
wiring diagrams read from the PDFs:
<https://bsai.com.mx/cdn/shop/files/ZKTECO-CMP200-Barrera--Vehicular-Manual-de-Operacion-Ingles.pdf>,
<https://manuals.plus/zkteco/cmp200-automatic-barrier-gate-manual.pdf>.
No public document names the `TT-DZ-200504E-A1` board, but a photo of our unit (user, 2026-11-14)
matches the **v1.2** layout: `MOTOR UP/COM/DOWN`, `COM/RED/GREEN`, `L/N/E`, `O.LM OUT`, `C.LM OUT`,
`STOP/DOWN/UP/STUDY` keys, status LEDs, and a 2x8 socket marked `RS485`. MCU is an **STC 15W408AS**
(8051 family); on-board transformer 220 V to 12 V / 600 mA; PCB date code 230602. The labels of
the low-voltage terminals sit under the plug-in connectors and were not visible — pull the plugs
to confirm them against the table.
## Terminal map (manual)
| Terminal | Function | Signal |
| --- | --- | --- |
| `G` / `STOP` / `DOWN` / `UP` | "Line-controlled interface": wired open/close/stop | dry contact, short to `G` |
| `G` / `DET` | vehicle (loop) detector | dry contact to `G` |
| `G` / `PHO` | infrared / "crash proof" sensor | dry contact to `G` |
| `CAR` (v1.2 only) | "count input" | dry contact to `G`; behaviour undocumented |
| `RS485 B / A / G` (v1.2 only) | "communication module" | see below |
| `+12V` / `G`, `+5V` / `G` | auxiliary supply | 12 V total under 100 mA |
| `O.LM OUT`, `C.LM OUT` | open-limit and close-limit relay outputs | volt-free NO/COM/NC each |
| `G` / `C.LM` / `O.LM` | external limit junction | — |
| `MOTOR UP/COM/DOWN`, `LAMP COM/RED/GREEN`, `L/N/E` | motor, AC traffic lamp, mains | **mains voltage** |
The v1.0 board has no RS485 and no `CAR`. The 4-pin `REMOTE` header takes the 433 MHz receiver.
## Behaviour the manual states
- `UP` during a fall reverses to rising at once. `DOWN` during a rise is ignored. `STOP` halts.
- `PHO` shorted during a fall: reverse to open, then **stay open**.
- `DET` shorted during a fall: reverse to open, then **close automatically** when released. `DET`
shorted while open or rising: the boom **falls by itself** once the detector clears. So `DET` is
both anti-smash and auto-close-after-passage, done in the barrier's own firmware.
- Timeout protection stops the motor if a travel exceeds the rise/fall time.
- No menu, no parameters, no auto-close timer are documented. Power-loss behaviour is not stated
beyond "manual release motor" — the boom does not lift by itself.
## Driving it from the [[dingtian-relay]]
**Relay contact, not RS485.** ZKTeco's own integration drawings (LPR camera, inBio260) wire a relay
`COM → G` and `NO → UP`. That is exactly our `pulseOpen`: one Dingtian relay, `COM` to `G`, `NO` to
`UP`, jogged. It expresses intent only and never times a close ([[barrier-not-a-door]]).
- **Closing** normally comes from the loop/radar on `DET`, in barrier firmware. Without a vehicle
tripping `DET` the boom stays up — the abandoned-entry free pass of [[passage-confirmation]].
- **Host close (only under [[passage-confirmation]]'s conditions):** a second relay on `DOWN`,
interlocked in series so it is dead while the open relay is active — relay 1 `COM → G`,
`NO → UP`, `NC →` relay 2 `COM`; relay 2 `NO → DOWN`. Never one relay with `NC → DOWN` (a
permanent close command; closes on controller power loss). Per the manual a `DET` or `PHO`
contact reverses a falling boom, so the close is not blind **if a detector is fitted** — to be
proven on the unit (test plan steps 2–3 there) before any use.
- **Status back to the host:** `O.LM OUT` and `C.LM OUT` are volt-free contacts, so they can go
straight onto two Dingtian inputs (contact to GND, like the button). That gives the host a real
"boom reached open / closed" signal for [[device-status-monitoring]] and for the anomaly "boom
opened with no signed host command" ([[threat-model]]).
- **Sharing a detector:** a radar/loop with one dry contact cannot feed both `DET` and a Dingtian
input directly (two different supplies on one contact). Use a detector with two relay outputs
or an interposing relay.
- Keep the low-voltage terminals apart from the mains block on the same board edge.
**RS485 — not a usable path today.**
1. The barrier's RS485 protocol is **undocumented**. The manual labels the terminals and a plug-in
"RS485 communication module" header and says nothing else: no baud, no address, no frames. On
our board the **socket is empty — no module fitted**, so the `B/A/G` terminals have no
transceiver behind them and are dead as shipped. Manuals for similar Chinese `DZ`-family boards show
a 4-byte, 9600 bps, XOR-checksum frame, but nothing ties that to this board — unverified.
2. The Dingtian's RS485 port is an **inbound control channel** (Modbus-RTU / Dingtian string: a
master commands the Dingtian). Stock firmware is not documented as an RS485 master or an
Ethernet-to-RS485 bridge, and our `harden()` disables that channel. `(unsourced beyond the
programming manual's protocol list — check the vendor manual before relying on either way)`
3. A serial "open" command would also be an unauthenticated open path on a wire in the lane
cabinet — worse than the password-carrying relay frame we already have.
## Open
- Pull the low-voltage plugs and read the silkscreen under them (`G DET CAR +12V G +5V G C.LM O.LM`
and `G STOP DOWN UP / B A G / G PHO` expected).
- What `CAR` does (probably queues several opens for a convoy) — test on the bench.
- Fail-state: on power loss the boom holds position, so "exit fails open" ([[fail-state-safety]])
needs the manual release or a UPS, not this board.