wiki: ZKTeco CMP200 barrier page, close-input wiring; park-lab reinstall gotchas
- entities/zkteco-cmp200-barrier: terminal map from the CMP200 manuals, board photo findings (v1.2 layout, RS485 socket empty), relay-contact drive from the Dingtian, interlocked close relay, limit outputs as status inputs - concepts/passage-confirmation: barrier model open question answered for the unit on hand - decisions/appliance-provisioning: Komodo gotchas 14-16 from the park-lab reinstall (2026-11-13) - index and log entries Co-Authored-By: Claude Fable 5.2 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01RZgP5ofaSqgLGHMGSL3xYN
This commit is contained in:
+30
@@ -3631,3 +3631,33 @@ sub-stream watcher, tracker over the existing YOLOX boxes, drawn segment, three
|
||||
lane-free on passage, evidence-driven close (standing decision to be revised after park-lab tests).
|
||||
Measured in park-lab's vision container: YOLOX-S@640 = 132/79/66 ms per frame at 2/4/6 threads;
|
||||
decode negligible. Stream test blocked: lab Dahua off, office Hikvisions need credentials.
|
||||
|
||||
## [2026-11-13] deploy | park-lab reinstalled from scratch — three Periphery/Docker gotchas
|
||||
|
||||
Fresh OS on park-lab; stack `stage-73ada89` deployed and healthy (proxy, server, vision). Three
|
||||
failures on the way, filed as Komodo gotchas 14–16 in [[appliance-provisioning]]: registry login
|
||||
`Os { code: 2 }` = Docker not installed; Periphery installed from the desktop account instead of
|
||||
`admin` (removed, re-onboarded from `admin`); `docker.sock` permission denied because the lingering
|
||||
user manager predated the `docker` group membership (fixed by reboot). Open on the box: the desktop
|
||||
account still holds `sudo`, `lxd`, `lpadmin`, `adm` — §5c demotion not yet applied.
|
||||
|
||||
## [2026-11-14] query | ZKTeco CMP200 barrier — wiring and Dingtian drive (web research)
|
||||
|
||||
Read the CMP200 manuals v1.0 and v1.2 (wiring diagrams). Drive = one Dingtian relay `COM→G`,
|
||||
`NO→UP` (ZKTeco's own LPR/inBio drawing); close comes from the detector on `DET` in barrier
|
||||
firmware; `O.LM`/`C.LM` volt-free outputs can feed Dingtian inputs as boom status. RS485 on the
|
||||
v1.2 board is undocumented and the Dingtian RS485 is an inbound control port — not a path. The
|
||||
board marking `TT-DZ-200504E-A1` appears in no public document. Filed: [[zkteco-cmp200-barrier]].
|
||||
|
||||
## [2026-11-14] query | CMP200 mainboard photo — v1.2 layout, RS485 socket empty
|
||||
|
||||
User photo of the `TT-DZ-200504E-A1` board: matches the manual's v1.2 layout; MCU STC 15W408AS;
|
||||
the `RS485` 2x8 socket carries no module, so the RS485 terminals are dead as shipped. Relay-contact
|
||||
drive stands. Updated [[zkteco-cmp200-barrier]].
|
||||
|
||||
## [2026-11-14] query | CMP200 close input for the abandoned-entry close
|
||||
|
||||
User raised the abandoned ANPR entry (boom left up, next car enters free) — the case
|
||||
[[passage-confirmation]] already covers. Recorded on [[zkteco-cmp200-barrier]]: close input is
|
||||
`DOWN`; wiring is two relays with a series interlock, never one relay `NC → DOWN`. Answered the
|
||||
"which operator model" open question on [[passage-confirmation]] for the unit on hand.
|
||||
|
||||
Reference in New Issue