wiki: ZKTeco CMP200 barrier page, close-input wiring; park-lab reinstall gotchas

- entities/zkteco-cmp200-barrier: terminal map from the CMP200 manuals, board
  photo findings (v1.2 layout, RS485 socket empty), relay-contact drive from
  the Dingtian, interlocked close relay, limit outputs as status inputs
- concepts/passage-confirmation: barrier model open question answered for the
  unit on hand
- decisions/appliance-provisioning: Komodo gotchas 14-16 from the park-lab
  reinstall (2026-11-13)
- index and log entries

Co-Authored-By: Claude Fable 5.2 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01RZgP5ofaSqgLGHMGSL3xYN
This commit is contained in:
2026-11-14 11:08:36 +01:00
parent 13ba593b69
commit 8b1f851add
5 changed files with 146 additions and 1 deletions
+3 -1
View File
@@ -110,7 +110,9 @@ credentials. Nothing of park-lab's device registry has a camera yet (only the re
- Window cap and "lane clear" dwell before a close (start: cap 60 s, dwell 3 s). - Window cap and "lane clear" dwell before a close (start: cap 60 s, dwell 3 s).
- Does the DS-2CD1043G2-LIU keep pushing VMD for a car *reversing*? (It should — motion is motion.) - Does the DS-2CD1043G2-LIU keep pushing VMD for a car *reversing*? (It should — motion is motion.)
- Stream-to-event latency and frame drop rate on the booth PC (measure, don't assume). - Stream-to-event latency and frame drop rate on the booth PC (measure, don't assume).
- Which barrier operator model is at the sites, and does park-lab have one for steps 1–6? - Which barrier operator model is at the sites? The unit on hand is a [[zkteco-cmp200-barrier]]:
its close input is `DOWN` (dry contact to `G`), and the manual says `DET`/`PHO` reverse a falling
boom — steps 1–3 can be run on it.
Related: [[lane-presence-and-anpr-entry]], [[barrier-not-a-door]], [[entry-double-press]], Related: [[lane-presence-and-anpr-entry]], [[barrier-not-a-door]], [[entry-double-press]],
[[append-only-event-chain]], [[opencv-anpr-service]], [[park-2-event-loop-stall]]. [[append-only-event-chain]], [[opencv-anpr-service]], [[park-2-event-loop-stall]].
+17
View File
@@ -605,3 +605,20 @@ board) and the SSD went into another OptiPlex 7070:
throughout (Periphery restarting itself never touches the already-running compose stack). throughout (Periphery restarting itself never touches the already-running compose stack).
**Always dry-run a version bump on a lab/dev box before a live booth**, even with a clean **Always dry-run a version bump on a lab/dev box before a live booth**, even with a clean
release-notes check — this project only had one lab box to test against and used it first. release-notes check — this project only had one lab box to test against and used it first.
14. **`Failed to login to image registry … Os { code: 2, kind: NotFound }` on Deploy = Docker is
not installed on the booth** (or `docker` is not on Periphery's PATH), NOT a credentials
problem. Periphery spawns `docker login`; the OS error is the missing executable. Periphery
onboards and shows green in Core without Docker, so the first sign is this deploy failure
(park-lab reinstall, 2026-11-13). §6 comes before §7 — do not skip it.
15. **Periphery goes under `admin`, never the operator/desktop account.** It needs the `docker`
group (root-equivalent) and linger; putting either on the auto-login account hands the
remote-exec agent to the adversary of [[threat-model]] (§5c). An install made from the wrong
account (park-lab, 2026-11-13, from the desktop user) is removed there (`systemctl --user
disable --now periphery`, delete its unit, binary, `~/.config/komodo`, `~/.komodo`) and
re-onboarded from `admin` with a new onboarding key and the same `--connect-as`.
16. **`permission denied … docker.sock` in Periphery's log although `admin` IS in `docker`:**
linger starts `admin`'s user manager at boot, so a manager started before `usermod -aG docker
admin` keeps the old group list, and so does every unit it launches. A fresh SSH login shows
the group; Periphery does not (`grep ^Groups /proc/$(pgrep -x periphery)/status` lacks the
docker gid). Restarting Periphery is not enough: `sudo systemctl restart user@$(id -u
admin).service` or reboot (park-lab, 2026-11-13).
+95
View File
@@ -0,0 +1,95 @@
---
type: entity
tags: [parking, hardware, barrier, relay, wiring]
sources: []
updated: 2026-11-14
---
# ZKTeco CMP200 Barrier Gate
The boom barrier on hand. Its mainboard (silkscreen on our unit: `TT-DZ-200504E-A1`) drives an
**AC capacitor-start motor** through on-board relays; limits are Hall switches. Mains 110/220 V AC,
100 W rated. Not to be confused with the [[zkteco-controller]] (access panel, rejected).
Web research 2026-11-14. Sources: ZKTeco CMP200 user manual v1.0 (2019) and v1.2 (March 2022),
wiring diagrams read from the PDFs:
<https://bsai.com.mx/cdn/shop/files/ZKTECO-CMP200-Barrera--Vehicular-Manual-de-Operacion-Ingles.pdf>,
<https://manuals.plus/zkteco/cmp200-automatic-barrier-gate-manual.pdf>.
No public document names the `TT-DZ-200504E-A1` board, but a photo of our unit (user, 2026-11-14)
matches the **v1.2** layout: `MOTOR UP/COM/DOWN`, `COM/RED/GREEN`, `L/N/E`, `O.LM OUT`, `C.LM OUT`,
`STOP/DOWN/UP/STUDY` keys, status LEDs, and a 2x8 socket marked `RS485`. MCU is an **STC 15W408AS**
(8051 family); on-board transformer 220 V to 12 V / 600 mA; PCB date code 230602. The labels of
the low-voltage terminals sit under the plug-in connectors and were not visible — pull the plugs
to confirm them against the table.
## Terminal map (manual)
| Terminal | Function | Signal |
| --- | --- | --- |
| `G` / `STOP` / `DOWN` / `UP` | "Line-controlled interface": wired open/close/stop | dry contact, short to `G` |
| `G` / `DET` | vehicle (loop) detector | dry contact to `G` |
| `G` / `PHO` | infrared / "crash proof" sensor | dry contact to `G` |
| `CAR` (v1.2 only) | "count input" | dry contact to `G`; behaviour undocumented |
| `RS485 B / A / G` (v1.2 only) | "communication module" | see below |
| `+12V` / `G`, `+5V` / `G` | auxiliary supply | 12 V total under 100 mA |
| `O.LM OUT`, `C.LM OUT` | open-limit and close-limit relay outputs | volt-free NO/COM/NC each |
| `G` / `C.LM` / `O.LM` | external limit junction | — |
| `MOTOR UP/COM/DOWN`, `LAMP COM/RED/GREEN`, `L/N/E` | motor, AC traffic lamp, mains | **mains voltage** |
The v1.0 board has no RS485 and no `CAR`. The 4-pin `REMOTE` header takes the 433 MHz receiver.
## Behaviour the manual states
- `UP` during a fall reverses to rising at once. `DOWN` during a rise is ignored. `STOP` halts.
- `PHO` shorted during a fall: reverse to open, then **stay open**.
- `DET` shorted during a fall: reverse to open, then **close automatically** when released. `DET`
shorted while open or rising: the boom **falls by itself** once the detector clears. So `DET` is
both anti-smash and auto-close-after-passage, done in the barrier's own firmware.
- Timeout protection stops the motor if a travel exceeds the rise/fall time.
- No menu, no parameters, no auto-close timer are documented. Power-loss behaviour is not stated
beyond "manual release motor" — the boom does not lift by itself.
## Driving it from the [[dingtian-relay]]
**Relay contact, not RS485.** ZKTeco's own integration drawings (LPR camera, inBio260) wire a relay
`COM → G` and `NO → UP`. That is exactly our `pulseOpen`: one Dingtian relay, `COM` to `G`, `NO` to
`UP`, jogged. It expresses intent only and never times a close ([[barrier-not-a-door]]).
- **Closing** normally comes from the loop/radar on `DET`, in barrier firmware. Without a vehicle
tripping `DET` the boom stays up — the abandoned-entry free pass of [[passage-confirmation]].
- **Host close (only under [[passage-confirmation]]'s conditions):** a second relay on `DOWN`,
interlocked in series so it is dead while the open relay is active — relay 1 `COM → G`,
`NO → UP`, `NC →` relay 2 `COM`; relay 2 `NO → DOWN`. Never one relay with `NC → DOWN` (a
permanent close command; closes on controller power loss). Per the manual a `DET` or `PHO`
contact reverses a falling boom, so the close is not blind **if a detector is fitted** — to be
proven on the unit (test plan steps 2–3 there) before any use.
- **Status back to the host:** `O.LM OUT` and `C.LM OUT` are volt-free contacts, so they can go
straight onto two Dingtian inputs (contact to GND, like the button). That gives the host a real
"boom reached open / closed" signal for [[device-status-monitoring]] and for the anomaly "boom
opened with no signed host command" ([[threat-model]]).
- **Sharing a detector:** a radar/loop with one dry contact cannot feed both `DET` and a Dingtian
input directly (two different supplies on one contact). Use a detector with two relay outputs
or an interposing relay.
- Keep the low-voltage terminals apart from the mains block on the same board edge.
**RS485 — not a usable path today.**
1. The barrier's RS485 protocol is **undocumented**. The manual labels the terminals and a plug-in
"RS485 communication module" header and says nothing else: no baud, no address, no frames. On
our board the **socket is empty — no module fitted**, so the `B/A/G` terminals have no
transceiver behind them and are dead as shipped. Manuals for similar Chinese `DZ`-family boards show
a 4-byte, 9600 bps, XOR-checksum frame, but nothing ties that to this board — unverified.
2. The Dingtian's RS485 port is an **inbound control channel** (Modbus-RTU / Dingtian string: a
master commands the Dingtian). Stock firmware is not documented as an RS485 master or an
Ethernet-to-RS485 bridge, and our `harden()` disables that channel. `(unsourced beyond the
programming manual's protocol list — check the vendor manual before relying on either way)`
3. A serial "open" command would also be an unauthenticated open path on a wire in the lane
cabinet — worse than the password-carrying relay frame we already have.
## Open
- Pull the low-voltage plugs and read the silkscreen under them (`G DET CAR +12V G +5V G C.LM O.LM`
and `G STOP DOWN UP / B A G / G PHO` expected).
- What `CAR` does (probably queues several opens for a convoy) — test on the bench.
- Fail-state: on power loss the boom holds position, so "exit fails open" ([[fail-state-safety]])
needs the manual release or a UPS, not this board.
+1
View File
@@ -46,6 +46,7 @@ Counts: 4 sources · 19 entities · 47 concepts · 9 decision records.
- [[dingtian-dt008-reader]] — Dingtian DT-008 QR/RFID reader on hand; HTTP-GET push, server replies the verdict; ⚠️ our two units read disjoint card sets (125 kHz vs 13.56 MHz) — unresolved, see open question #18. - [[dingtian-dt008-reader]] — Dingtian DT-008 QR/RFID reader on hand; HTTP-GET push, server replies the verdict; ⚠️ our two units read disjoint card sets (125 kHz vs 13.56 MHz) — unresolved, see open question #18.
- [[zkteco-controller]] — ❌ rejected/historical; aux-input path was a contender, not pursued. - [[zkteco-controller]] — ❌ rejected/historical; aux-input path was a contender, not pursued.
- [[dingtian-relay]] — ✅ CHOSEN access controller; decoupled inputs solve the button blocker (driver verified on hardware); spare relays drive aux outputs (`setAux`). - [[dingtian-relay]] — ✅ CHOSEN access controller; decoupled inputs solve the button blocker (driver verified on hardware); spare relays drive aux outputs (`setAux`).
- [[zkteco-cmp200-barrier]] — the boom barrier on hand: mainboard terminal map, relay-contact drive from the Dingtian, limit outputs as status inputs; RS485 undocumented.
- [[relay-proxy-firmware]] — RETIRED 2026-10-23 (mini PCs instead). PoC (2026-10-22): NodeMCU firmware that IS a DT-R004 to the booth (binary/string UDP, config CGI, userset, Digest push) + cloud heartbeat/command/watchdog (power-cycles the PC). Verified against the emulator and end to end at park-lab (2026-10-22, after the ufw rule). - [[relay-proxy-firmware]] — RETIRED 2026-10-23 (mini PCs instead). PoC (2026-10-22): NodeMCU firmware that IS a DT-R004 to the booth (binary/string UDP, config CGI, userset, Digest push) + cloud heartbeat/command/watchdog (power-cycles the PC). Verified against the emulator and end to end at park-lab (2026-10-22, after the ufw rule).
- [[dahua-ipc-hfw2549t]] — first Dahua on the bench (IPC-HFW2549T-AS-IL, fw 2.880, 2026-09-17): the driver's channel decrement gave HTTP 400 (channels are 1-based — fixed + verified live); Dahua clock-sync built (`global.cgi`, naive wall time); events = held `eventManager attach` multipart stream, verbatim `VideoMotion Start/Stop` + `TimeChange` parts captured, subscriber not built; `RealUTC` is the camera's belief of UTC; 5-strike login lockout. - [[dahua-ipc-hfw2549t]] — first Dahua on the bench (IPC-HFW2549T-AS-IL, fw 2.880, 2026-09-17): the driver's channel decrement gave HTTP 400 (channels are 1-based — fixed + verified live); Dahua clock-sync built (`global.cgi`, naive wall time); events = held `eventManager attach` multipart stream, verbatim `VideoMotion Start/Stop` + `TimeChange` parts captured, subscriber not built; `RealUTC` is the camera's belief of UTC; 5-strike login lockout.
- [[hikvision-radar]] — vehicle-presence radar on a Dingtian input; the entry presence gate (per-input active-level caveat). - [[hikvision-radar]] — vehicle-presence radar on a Dingtian input; the entry presence gate (per-input active-level caveat).
+30
View File
@@ -3631,3 +3631,33 @@ sub-stream watcher, tracker over the existing YOLOX boxes, drawn segment, three
lane-free on passage, evidence-driven close (standing decision to be revised after park-lab tests). lane-free on passage, evidence-driven close (standing decision to be revised after park-lab tests).
Measured in park-lab's vision container: YOLOX-S@640 = 132/79/66 ms per frame at 2/4/6 threads; Measured in park-lab's vision container: YOLOX-S@640 = 132/79/66 ms per frame at 2/4/6 threads;
decode negligible. Stream test blocked: lab Dahua off, office Hikvisions need credentials. decode negligible. Stream test blocked: lab Dahua off, office Hikvisions need credentials.
## [2026-11-13] deploy | park-lab reinstalled from scratch — three Periphery/Docker gotchas
Fresh OS on park-lab; stack `stage-73ada89` deployed and healthy (proxy, server, vision). Three
failures on the way, filed as Komodo gotchas 14–16 in [[appliance-provisioning]]: registry login
`Os { code: 2 }` = Docker not installed; Periphery installed from the desktop account instead of
`admin` (removed, re-onboarded from `admin`); `docker.sock` permission denied because the lingering
user manager predated the `docker` group membership (fixed by reboot). Open on the box: the desktop
account still holds `sudo`, `lxd`, `lpadmin`, `adm` — §5c demotion not yet applied.
## [2026-11-14] query | ZKTeco CMP200 barrier — wiring and Dingtian drive (web research)
Read the CMP200 manuals v1.0 and v1.2 (wiring diagrams). Drive = one Dingtian relay `COM→G`,
`NO→UP` (ZKTeco's own LPR/inBio drawing); close comes from the detector on `DET` in barrier
firmware; `O.LM`/`C.LM` volt-free outputs can feed Dingtian inputs as boom status. RS485 on the
v1.2 board is undocumented and the Dingtian RS485 is an inbound control port — not a path. The
board marking `TT-DZ-200504E-A1` appears in no public document. Filed: [[zkteco-cmp200-barrier]].
## [2026-11-14] query | CMP200 mainboard photo — v1.2 layout, RS485 socket empty
User photo of the `TT-DZ-200504E-A1` board: matches the manual's v1.2 layout; MCU STC 15W408AS;
the `RS485` 2x8 socket carries no module, so the RS485 terminals are dead as shipped. Relay-contact
drive stands. Updated [[zkteco-cmp200-barrier]].
## [2026-11-14] query | CMP200 close input for the abandoned-entry close
User raised the abandoned ANPR entry (boom left up, next car enters free) — the case
[[passage-confirmation]] already covers. Recorded on [[zkteco-cmp200-barrier]]: close input is
`DOWN`; wiring is two relays with a series interlock, never one relay `NC → DOWN`. Answered the
"which operator model" open question on [[passage-confirmation]] for the unit on hand.