feat(firmware): relay-proxy PoC — NodeMCU as a Dingtian DT-R004 + cloud proxy/watchdog
A NodeMCU v3 (ESP8266) that speaks the Dingtian wire contract (binary UDP 60000 with relay_pw, string UDP 60001, config CGI incl. the setconfig gotcha, userset.cgi, Digest input push) so the booth's existing driver needs no change, plus a heartbeat/command/ watchdog path to an ephemeral cloud stand-in (poc/cloud-standin.mjs). Verified at park-lab: the booth's assign flow configured it like real hardware and a button press reached the booth (401→Digest→200) and the cloud with the booth's status. Watchdog probes /health and power-cycles the PC via a spare relay with backoff. IO behind one interface for the ESP32/ Dingtian port. wiki: relay-proxy-firmware page; esp32-flashability-test runbook (esptool lock test); dingtian-relay "can we flash our own firmware" (vendor locks the standard SKU); site-device-installation: booth ufw must allow device-net → 3000 (push targets PORT, not Caddy's 80); open-questions: cloud takeover vs signed ledger (parked). .gitignore: firmware venv/.pio/secrets.h.
This commit is contained in:
@@ -46,6 +46,7 @@ Counts: 4 sources · 19 entities · 47 concepts · 8 decision records.
|
||||
- [[dingtian-dt008-reader]] — Dingtian DT-008 QR/RFID reader on hand; HTTP-GET push, server replies the verdict; ⚠️ our two units read disjoint card sets (125 kHz vs 13.56 MHz) — unresolved, see open question #18.
|
||||
- [[zkteco-controller]] — ❌ rejected/historical; aux-input path was a contender, not pursued.
|
||||
- [[dingtian-relay]] — ✅ CHOSEN access controller; decoupled inputs solve the button blocker (driver verified on hardware); spare relays drive aux outputs (`setAux`).
|
||||
- [[relay-proxy-firmware]] — PoC (2026-10-22): NodeMCU firmware that IS a DT-R004 to the booth (binary/string UDP, config CGI, userset, Digest push) + cloud heartbeat/command/watchdog (power-cycles the PC). Verified against the emulator; booth integration blocked on park-lab ufw.
|
||||
- [[dahua-ipc-hfw2549t]] — first Dahua on the bench (IPC-HFW2549T-AS-IL, fw 2.880, 2026-09-17): the driver's channel decrement gave HTTP 400 (channels are 1-based — fixed + verified live); Dahua clock-sync built (`global.cgi`, naive wall time); events = held `eventManager attach` multipart stream, verbatim `VideoMotion Start/Stop` + `TimeChange` parts captured, subscriber not built; `RealUTC` is the camera's belief of UTC; 5-strike login lockout.
|
||||
- [[hikvision-radar]] — vehicle-presence radar on a Dingtian input; the entry presence gate (per-input active-level caveat).
|
||||
- [[rongta-printer]] — ✅ CHOSEN 80mm thermal printer; ESC/POS over raw TCP 9100 (or local USB, see [[printer-usb-transport]]); driver written, one unit reachable at 10.0.10.6.
|
||||
@@ -70,6 +71,7 @@ Counts: 4 sources · 19 entities · 47 concepts · 8 decision records.
|
||||
- [[device-registry]] — catalog of selectable drivers per category (admin-configurable).
|
||||
- [[first-run-setup]] — admin adds controllers + binds readers/cameras to relays from the catalog at install.
|
||||
- [[site-device-installation]] — FIELD RUNBOOK (2026-09-09): per device — factory address + credentials, the tool needed, what the wizard configures itself vs what is done by hand on the device, known traps; address plan, order of work on site, gaps to fill. Dingtian relay, DT-008 readers, Hikvision camera, radar, K200L / Rongta / Cashino printers.
|
||||
- [[esp32-flashability-test]] — BENCH RUNBOOK (2026-10-22): is this ESP32 board locked? `esptool chip_id` + `espefuse summary` on the Dingtian DT-R0xx programming header; read-only; locked = standard SKU, open = Development Board Version.
|
||||
- [[device-input-flow]] — button → device push → backend decides → relay; backend is source of truth.
|
||||
- [[device-discovery]] — optional driver capability to scan the LAN; implemented by the DT-008 reader (2026-10-08), UHPPOTE was the historical example.
|
||||
- [[barrier-not-a-door]] — never timed-close a barrier; safety lives in barrier firmware.
|
||||
|
||||
Reference in New Issue