Commit Graph

7 Commits

Author SHA1 Message Date
julian f6e35bbebf fix(reader): correct the QR reader's identity — Dingtian DT-008, not "GEE"
Build desktop / desktop (push) Successful in 4m16s
Build & push images / images (push) Successful in 2m46s
CI / check (push) Successful in 38s
An early wrong assumption named the QR/RFID access reader "GEE" /
"GEE/Fondvision" / "GEE-QR-ER80" (and summarized a raw GEE PDF as its
datasheet). There is no GEE device — it's the Dingtian DT-008
(dingtian-tech.com/en_us/qr_code_reader.html), the same vendor as the relay
board, which is why it integrates the identical HTTP-GET-push way.

Code:
- Driver symbol geeQrReaderDriver → dingtianQrReaderDriver; label →
  "Dingtian DT-008 QR/RFID reader (HTTP push)"; comments/description rewritten
  to the real DT-008 facts (Wiegand 26/34, TCP/IP, USB, RS485 — not RS-232;
  QR/barcode + ID/IC/NFC — not DataMatrix/1D).
- Persisted driverId "gee-qr-reader" → "dingtian-qr-reader" (the registry
  lookup key + the row created on assign in qr-reader.ts).
- Migration 0015 rewrites existing devices.driver_id rows so configured readers
  keep resolving (applied to the dev DB — 2 rows; the booth applies it on boot).
  Behaviour is unchanged: naming + the persisted id only.

Wiki + memory:
- Renamed entities/gee-qr-er80.md → dingtian-dt008-reader.md and
  sources/gee-qr-er80.md → dingtian-dt008.md; rewrote both to the real DT-008
  product-page specs while KEEPING all the verified-on-hardware protocol facts
  (cjihao serial, .jsp path, Connection: close). Fixed every cross-reference +
  "GEE" mention in 6 other pages. Memory gee-reader-serial-binding →
  dingtian-reader-serial-binding. The only surviving "GEE" mentions are
  deliberate naming-correction notes, the raw PDF filename, and the
  append-only log history.

Full workspace build/lint/test green; dev DB readers verified resolving to the
registered dingtian-qr-reader driver.

Claude-Session: https://claude.ai/code/session_01Xcm6ikLgGoCxxHrxtjkk5V
2026-06-28 17:39:15 +02:00
julian b8ddda86e7 feat(subscription): RFID enrollment, any-credential exit, prepaid booth handling
Rounds out subscriptions across enrollment, the barrier flow, and the booth.

- RFID credentials enabled with a "Read card" enrollment flow: the operator
  arms ONE chosen reader (CredentialCapture, single-shot + ~30s TTL); that
  reader's next read is captured into the form and NOT dispatched to the access
  flow — the OTHER reader keeps serving live entry/exit. Routes:
  /api/subscriptions/readers + /capture/{arm,cancel} + poll.
- Enter with one credential, exit with another: sessions are keyed by a
  per-occurrence id (SUBSESS-<short>), not the credential value, with
  permitId in the payload. Direction is decided by the barrier the reader sits
  at (entry-lane→entry, exit-lane→exit; "both" infers); a fleet (maxConcurrent>1)
  admits several cars and exits any with any credential, FIFO (oldest first).
- Booth treats a subscription occurrence as PREPAID: never quoted/charged; the
  pay/exit modal shows a subscription mode (snapshots + a single audited
  Open-barrier action) to assist a faulty exit reader / missing card;
  reopenBarrier authorizes paidAt!=null OR subscription. Active Sessions badges
  "abonim" and labels by holder name (not the raw key).
- Plus a per-read diagnostic log in the QR-reader route (serial → device →
  verdict/dir), which surfaced the earlier duplicate-reader-IP misroute.

Verified via buildServer+inject + reader-scan/TCP-capture simulations
(enrollment isolation, cross-credential + FIFO fleet, prepaid-not-charged,
subscription reopen, unpaid-transient guard). Updated wiki (subscription,
booth-exit-flow). No migration.

Claude-Session: https://claude.ai/code/session_01Xcm6ikLgGoCxxHrxtjkk5V
2026-06-18 16:26:48 +02:00
julian 1efa77bf56 devices: pool-of-spaces model — drop lane, per-relay direction
A parking lot is one pool of spaces with a flexible set of entry/exit
points — no "lane". Direction is a property of each RELAY inside an access
controller; readers/cameras bind to a controller relay and inherit it.

Schema:
- drop `lane` from ledger_events, device_events, sessions
- rename lane_devices -> devices (no lane/direction columns)
- access config.relays=[{relay,direction,button?}]; reader/camera
  config.controllerId+relay binding
- fresh 0000_baseline migration (history reset; dev data was throwaway)

Signed ledger:
- remove `lane` from canonicalize(); bump signer keyId sw-hmac-v1 -> v2
  (v1 events won't verify under v2 — intentional, gated per-event by keyId)

Server:
- new device-resolve.ts (replaces lane-map.ts): relayForButton,
  relayForDevice, firstRelayByDirection, devicesByDirection
- entry-flow: button terminal -> its relay; exit/permit: reader's bound
  relay; dispatcher resolves the bound relay + inherited direction
- camera snapshots fire by direction site-wide, async, never block open
- DeviceConfig widened to nested JSON for relays[]

Web:
- wizard: no lane selector; add controllers (relay map + entry-button
  terminal) first, then bind readers/cameras/printers to a controller relay

Wiki: new entry-exit-points.md (replaces lane-direction); reworked
entry-exit-readers, parking-session, first-run-setup, device-registry,
append-only-event-chain, device-events; removed stale lane/LaneMap mentions.
2026-06-16 20:29:38 +02:00
julian ff3b011fe0 qr-reader: reply Connection: close (fixes ~10s beep delay)
The reader sends Connection: keep-alive but only acts on the verdict (beep,
output) once the TCP socket closes. Fastify's default kept the connection alive,
so the reader waited out a ~10s keep-alive timeout before beeping — even though
the server replied in ~15ms. Every vendor demo replies Connection: close and
shuts the socket. Set reply.header('connection','close') on the QR endpoint.

Verified the header is now sent; symptom was correct accept/reject with a ~10s
lag before the beep.
2026-06-16 12:56:10 +02:00
julian 68d61f2d99 qr-reader: gee-qr-reader driver — assign in wizard, resolve lane by serial
The QR reader is a push device and the setup wizard assigns random-UUID ids, so
'id = serial' can't be set via the UI. Add a dedicated gee-qr-reader driver
(reader category) with a single 'serial' config field; the admin assigns it
normally and enters the device's serial (its cjihao).

The QR endpoint now resolves the lane by matching lane_devices.config.serial to
the scan's cjihao (instead of row id == cjihao), so no DB hand-editing. An
unassigned serial resolves to no lane -> status:0, gracefully.

Verified via inject through the real /api/setup/assign: assign {serial:
H05M2AFA} -> .jsp scan with a matching permit QR -> status:1 (accept) + open;
re-scan -> permit exit; unknown card -> status:0; unassigned serial -> status:0.
2026-06-16 12:36:58 +02:00
julian 04135b27cf qr-reader: register all server-language extensions (reader posts .jsp)
Hardware capture: the GEE/Fondvision reader (serial H05M2AFA) scans + sends +
beeps fine — the earlier 'no beep' was just nothing answering :3000. Real
request: GET /qa/mcardsea.jsp?cardid=...&cjihao=H05M2AFA&... — the 'server
language' setting (JSP here) selects the URL EXTENSION, so it posts .jsp, not
.php. Our route was .php-only and would have 404'd it.

Register the endpoint at php/jsp/asp/aspx/cgi so it works whatever the device is
configured to. cjihao (serial) is the lane key: assign the reader as
lane_devices.id = its serial.
2026-06-16 12:30:00 +02:00
julian 392d44d842 server: GEE/Dingtian QR reader endpoint + synchronous ReadOutcome
The reader HTTP-GETs on each scan and beeps/acts on our JSON reply (host-in-the-
loop, synchronous). New route GET/POST /qa/mcardsea.php parses the SDK query,
runs the scan through the read dispatcher (permit match -> permit flow; else
transient exit), and replies the SDK verdict: status 1=valid (beep 2x) /
0=invalid (beep 1x), output, time-sync.

Refactored the read flows to return a ReadOutcome {accepted, direction, reason}
so the reply reflects the real accept/reject decision (ReadDispatcher.dispatch,
ExitFlow.handleAt, PermitFlow.run). Fire-and-forget readers ignore it.

Reader's lane is keyed off its serial (cjihao) as lane_devices.id for now;
endpoint is public (reader has no auth, on the device subnet).

Verified via inject: valid permit QR -> status:1 + open; re-scan -> permit exit;
unknown QR -> status:0; barrier-less lane -> status:0.
2026-06-16 12:12:09 +02:00