- lpr-camera.md: "503 Device Busy" can be PERSISTENT (main-stream saturation on
the G3H) — the real fix is sub-stream selection, not just retry.
- device-status-monitoring.md: QR reader health was false-healthy (hardcoded
"ready") until the ICMP-ping fix; document the push-device monitoring model.
- log entries for both 2026-06-26 sessions.
Claude-Session: https://claude.ai/code/session_01Xcm6ikLgGoCxxHrxtjkk5V
Generalise printer-only monitoring to every configured device. New
DeviceMonitor polls all enabled devices each tick (default 8s): printers
via rich readStatus(), relays/readers/cameras via the generic healthCheck()
reachability probe, flattened to one traffic-light (ready/degraded/offline)
+ detail, deduped (emit on change only), fail-toward-offline.
- device-status bus event + GET /api/devices/status snapshot.
- Pushed over the existing /api/ws (hello carries the initial set;
device-status frame per change).
- Web: live-store devices map, WS handler, DeviceFooter chip-per-device
(role label not vendor; click a degraded/offline chip for an issues panel).
Verified roleKind resolution + change-only emit on a fresh DB.
Note: the footer's UI surface (api type, router mount, i18n devices) rides
in the subsequent subscription commit due to shared-file overlap.
Claude-Session: https://claude.ai/code/session_01Xcm6ikLgGoCxxHrxtjkk5V