An early wrong assumption named the QR/RFID access reader "GEE" /
"GEE/Fondvision" / "GEE-QR-ER80" (and summarized a raw GEE PDF as its
datasheet). There is no GEE device — it's the Dingtian DT-008
(dingtian-tech.com/en_us/qr_code_reader.html), the same vendor as the relay
board, which is why it integrates the identical HTTP-GET-push way.
Code:
- Driver symbol geeQrReaderDriver → dingtianQrReaderDriver; label →
"Dingtian DT-008 QR/RFID reader (HTTP push)"; comments/description rewritten
to the real DT-008 facts (Wiegand 26/34, TCP/IP, USB, RS485 — not RS-232;
QR/barcode + ID/IC/NFC — not DataMatrix/1D).
- Persisted driverId "gee-qr-reader" → "dingtian-qr-reader" (the registry
lookup key + the row created on assign in qr-reader.ts).
- Migration 0015 rewrites existing devices.driver_id rows so configured readers
keep resolving (applied to the dev DB — 2 rows; the booth applies it on boot).
Behaviour is unchanged: naming + the persisted id only.
Wiki + memory:
- Renamed entities/gee-qr-er80.md → dingtian-dt008-reader.md and
sources/gee-qr-er80.md → dingtian-dt008.md; rewrote both to the real DT-008
product-page specs while KEEPING all the verified-on-hardware protocol facts
(cjihao serial, .jsp path, Connection: close). Fixed every cross-reference +
"GEE" mention in 6 other pages. Memory gee-reader-serial-binding →
dingtian-reader-serial-binding. The only surviving "GEE" mentions are
deliberate naming-correction notes, the raw PDF filename, and the
append-only log history.
Full workspace build/lint/test green; dev DB readers verified resolving to the
registered dingtian-qr-reader driver.
Claude-Session: https://claude.ai/code/session_01Xcm6ikLgGoCxxHrxtjkk5V
Two genuinely-offline QR readers showed GREEN: the adapter's healthCheck was
hardcoded to { ready, "stub" } and never probed. These are PUSH devices (scan →
GET our backend, resolve by serial) with NO TCP port, so a connect probe has
nothing to hit — the stub "solved" that by lying. False-healthy is the worst
failure for a status bar.
- Optional reader IP field (monitor-ONLY; scans still resolve by serial,
operation unchanged).
- Unprivileged ICMP ping (drivers/icmp.ts): shells /bin/ping -c1, exit-0 = reply.
No native dep, no CAP_NET_RAW. docker-compose.prod.yml sets
net.ipv4.ping_group_range so it works for the non-root container user.
- healthCheck: replies → ready, no reply → offline, NO IP → degraded
("set IP to monitor") — never a false green.
Verified on hardware: readers (10.0.10.7/.8) answer ICMP on the device VLAN;
UI Test connection → "● ready — ping 10.0.10.7". Tests: reader.test.ts (4).
Claude-Session: https://claude.ai/code/session_01Xcm6ikLgGoCxxHrxtjkk5V
The QR reader is a push device and the setup wizard assigns random-UUID ids, so
'id = serial' can't be set via the UI. Add a dedicated gee-qr-reader driver
(reader category) with a single 'serial' config field; the admin assigns it
normally and enters the device's serial (its cjihao).
The QR endpoint now resolves the lane by matching lane_devices.config.serial to
the scan's cjihao (instead of row id == cjihao), so no DB hand-editing. An
unassigned serial resolves to no lane -> status:0, gracefully.
Verified via inject through the real /api/setup/assign: assign {serial:
H05M2AFA} -> .jsp scan with a matching permit QR -> status:1 (accept) + open;
re-scan -> permit exit; unknown card -> status:0; unassigned serial -> status:0.
Make the device-adapter pattern selectable so the admin chooses hardware at
install — per lane, from a catalog of supported drivers. Adding a device =
registering one more driver; no business-logic change.
packages/devices:
- interfaces.ts: AccessControlDevice / ReaderDevice / CameraDevice / PrinterDevice
(adds CameraDevice for entry/exit snapshot-on-event; access relay stays
intent-only per "a barrier is not a door").
- registry.ts: driver catalog with per-driver config fields + factory, config
validation, and a catalog payload for the setup UI.
- drivers/: stub adapters — access (zkteco, esp32-relay), reader (wiegand,
tcp-ip), camera (hikvision, dahua). Real vendor protocols TBD.
packages/db:
- lane_devices + setup_state tables (migration 0001); re-export query helpers.
apps/server:
- routes/setup.ts: GET /api/setup/catalog (public schema), and admin-only
/assign, /state, /complete with registry validation before persisting.
- extract auth.ts (requireJwtSecret, requireRole, JWT type aug).
apps/web:
- SetupWizard scaffold + api client: pick a driver per category for a lane,
render its config fields.
wiki: device-registry + first-run-setup concept pages; cross-link from
device-adapter-pattern; index + log updated.
Verified: full turbo build (5/5); catalog lists all drivers; admin assign
persists; missing-config and no-token requests are rejected.