--- type: entity tags: [parking, hardware, readers, qr, dingtian] sources: [dingtian-dt008] updated: 2026-09-17 status: open --- # Dingtian DT-008 (QR/RFID access reader) The project's **QR / barcode / RFID reader** — Dingtian **DT-008**, the **same vendor as the [[dingtian-relay|relay board]]** (which is why it integrates the same HTTP-push way). A static optical + card scanner for **QR / barcode (simple)** and **ID/IC/NFC cards**. This is the **[[ticket-encoding|QR ticket]]** scanner (read at the pay station / exit lane) and a path for **QR or RFID [[subscription]]** credentials. Product page: dingtian-tech.com/en_us/qr_code_reader.html. (See [[dingtian-dt008|spec summary]] / `raw/`.) > **Naming correction (2026-06-28).** Through most of this project this reader was wrongly called > **"GEE" / "GEE/Fondvision" / "GEE-QR-ER80"** — a bad early assumption. There is no GEE device; it > is the **Dingtian DT-008**. The driver id was renamed `gee-qr-reader` → `dingtian-qr-reader` > (migration 0015 rewrites existing rows). All *protocol/behaviour* facts below were observed on the > real hardware and remain correct — only the device identity was wrong. ## What it is - **QR/barcode + card.** Reads **QR / simple barcode** AND **ID/IC/NFC cards** (~0.2 s, 0–10 cm). (An earlier note guessed "ER80-EM = 125 kHz EM4100 prox" — that was part of the same mis-id.) - **Interfaces: Wiegand 26/34, TCP/IP, USB, RS485** per the product page; the box leaflet ([[dingtian-dt008-box-manual]]) also lists **RS232**. (An earlier note dismissed RS-232 as a claim from the mis-identified GEE PDF — withdrawn 2026-09-17.) For our integration it talks **HTTP over TCP/IP**; Wiegand is the reader's *output line* on a valid read, not the host transport. - **Power** 9–16 V DC, 800 mA; **86×86×42 mm**; −30…70 °C. Fits the [[disk-os-hardening|appliance]]. ## How it integrates — HTTP-GET push, server replies the verdict (confirmed via SDK) The protocol is settled by the **[[qrcode-sdk|QRCode SDK v1.6.5]]** (not serial as first guessed). The reader is configured (Windows tool `QRCode_v1_6_5.exe`) with a **server IP/port** and a "server language" (only picks the URL path, e.g. `/qa/mcardsea.php`). **On each scan it HTTP-GETs the host:** ``` GET /qa/mcardsea.php?cardid=&mjihao=&cjihao=&status=<2 chars>&time= ``` `cardid` = scanned data; `status` low digit = **direction (1=in / 0=out)**. The host replies JSON `{data:[{cardid,cjihao,mjihao,status,time,output}],code:0}` where reply **`status` 1=valid (beep 2×) / 0=invalid (beep 1×)**, **`output` 0=Access/1=WG26/2=WG34**, `time` syncs the clock. This is **host-in-the-loop and SYNCHRONOUS**: the GET *is* the access query and **our reply is the decision** — it drives the reader's beep + output. So unlike a fire-and-forget reader, the endpoint must decide (valid/invalid, direction from `status`) and reply, then also emit a `DeviceReadEvent` on the `read` bus for the entry/exit/permit flows ([[parking-session]], [[subscription]]) to open the barrier. ([[device-input-flow]] is the analogous push pattern; this one also returns a verdict.) > **This explains the "no beep":** feedback comes from the server's JSON reply, not locally. A > non-JSON / missing reply ⇒ no beep even though the scan worked. So "no beep" ≠ "didn't scan." - Pushes over plain **HTTP** to our `10.0.10.x` host (on the device subnet); no serial wiring, no Wiegand-decode hardware. Suits the host-in-the-loop model; autonomy is moot anyway ([[dingtian-relay]] has no onboard ACL). - Default IP `192.168.1.99` (set its server IP/port to this host in the vendor tool). ## Resolved (2026-06-16) - Protocol = HTTP GET poll + JSON verdict (above). The earlier "serial/Wiegand, find the baud" open questions are **moot** — it's HTTP. Wiegand is the reader's *output line* on a valid read (the reply `output` field), not the host transport. ## As-built (2026-06-16) - **Endpoint** `GET/POST /qa/mcardsea.php` (`apps/server/src/routes/qr-reader.ts`, public — the reader has no auth, sits on the device subnet). Parses `cardid/mjihao/cjihao/status/time`, runs the scan through the **read dispatcher** (permit match → permit flow; else transient exit), and replies the **SDK verdict**: `status` 1=valid(beep 2×)/0=invalid(beep 1×), `output` 0, `time`. - The read flows were refactored to **return a `ReadOutcome` { accepted, direction, reason }** so the endpoint's reply reflects the real accept/reject (the dispatcher decides AND opens the barrier via the flows). A fire-and-forget reader ignores the outcome. - **Reader identity:** the endpoint matches the device **serial (`cjihao`)** against each reader's `config.serial` to find its `devices` row; the dispatcher then resolves the relay that row is **bound** to (`config.controllerId` + `relay`) and opens it. See [[entry-exit-points]]. - Verified via inject: valid permit QR → `status:1` + open; re-scan → permit exit (still valid); unknown QR → `status:0`; reader on a barrier-less lane → `status:0`. ## Verified on hardware (2026-06-16) Captured a real scan (vendor-emulator logger on :3000). The reader **does scan, send, and beep** — the earlier "no beep" was simply that no server was answering on :3000 with valid JSON. Real GET: ``` GET /qa/mcardsea.jsp?cardid=52020056&mjihao=1&cjihao=H05M2AFA&status=11&time=1781634494 from 10.0.10.7 (referer: http://www.fondvision.com — the OEM is Fondvision) ``` - **PATH carries the configured "server language" EXTENSION:** this unit is set to **JSP**, so it GETs **`/qa/mcardsea.jsp`** — NOT `.php`. Our endpoint was registered at `.php` only → it would have 404'd the real reader. **Fixed:** the route now registers `php/jsp/asp/aspx/cgi`. - **`cjihao` = `H05M2AFA`** is the device **serial** — the value our endpoint matches against the reader's `config.serial`. So assign the reader with **`config.serial = "H05M2AFA"`** and bind it to a controller relay. - **`mjihao` = 1** (device id). `cardid` = the scanned barcode (`52020056`). `status=11`. - The reader **beeped on the vendor reply with `status:0`** — so it acts on the reply; `0` = invalid/1-beep as documented. A matching permit/session will return `status:1` → 2-beep accept. ## Assignment (as-built 2026-06-16) A dedicated **`dingtian-qr-reader`** driver ([[device-registry]], reader category) models the push reader: its one config field is **`serial`** (the `cjihao` the device reports). The admin assigns it in the [[first-run-setup|setup wizard]] like any device (normal UUID row id), enters the serial, and binds it to a controller relay. The QR endpoint resolves the reader by **matching `config.serial` to the scan's `cjihao`** — not by row id — so no DB hand-editing. Set the reader's server IP/port to this host in the **vendor tool**; assign + enter its serial + bind it here. - Verified via inject: assign `dingtian-qr-reader` {serial:"H05M2AFA"} bound to an access relay → a `.jsp` scan with that serial + a matching permit QR → `status:1` (2-beep accept) + open; re-scan → permit exit; unknown card → `status:0`; unassigned serial → `status:0` (no relay, graceful). - Note `tcpip-reader` is the WRONG model for this device (host-connects-out, a stub) — use `dingtian-qr-reader`. ## Open / next - Re-test on hardware against the real app (now `.jsp`-aware + serial-resolved): scan → expect a `status:1` 2-beep when the QR matches a permit/open session. - `output` is replied as `0` (Access). Confirm on hardware whether the reader needs `1`/`2` (WG26/34) to drive its access line, vs. `0`. ## Channel tagging — output prefixes close the printed-card-clone hole (2026-07-04) The push carries ONE opaque `cardid` whether the **optical** engine decoded a QR/barcode or the **RF** engine read a card — the server couldn't tell. And `SubscriptionFlow.match` matched by **value only** (the stored `rf`/`qr` kind was a label). Consequence: printing a card's UID (often written on the card face, e.g. `86A158`) as a barcode and holding it up **cloned the RF card** — the optical decode matched the RF credential and opened the barrier. In-threat-model and cheap. **Fix (both sides):** - **Reader (vendor tool, both units):** set `QRCode Output Prefix` = `Q:` and `Card Output Prefix` = `K:` (env-overridable server-side: `READER_QR_PREFIX` / `READER_CARD_PREFIX`). - **Server:** `routes/qr-reader.ts` strips the prefix and tags the read's confirmed channel (`DeviceReadEvent.channel: "optical"|"rf"`; kind `qr`/`card`). Enrollment capture stores the **bare** value. `SubscriptionFlow.match` then requires **channel agreement**: an optical read may not claim an `rf` credential (and vice versa) — a mismatch is refused AND signs a `sub.refused.channelMismatch` **anomaly** (a clone attempt is a fraud signal). An **unprefixed** read keeps the legacy untagged shape and matches as before — enforcement only bites where prefixes are deployed, so an unconfigured reader never breaks. - Bonus: every `READ` log line now carries `ch=optical|rf`, which permanently attributes any future phantom (see below) to its engine. ⚠️ **Two device-side settings are now part of the credential contract** (they live ON the reader, not in our DB — re-apply after any factory reset/swap): the two **output prefixes** (must match the server's expected `Q:`/`K:`), and **`Card Input format` (currently `6H`)** — it defines the UID shape we enroll; changing it later silently orphans every enrolled card. ## ⚠️ Phantom optical decodes from sunlight patterns (park-buzi, 2026-07-04) With the site EMPTY (pre-opening, verified live + by snapshot), the **exit reader (`cjihao=H05MA5B0`) pushed spontaneous scans** at random afternoon times (observed 16:38–18:14, low-western-sun hours): `cardid` values like `997492`, `389861`, `024358`, `192793` — and once a lone **`C`**. Server logs (`READ serial=` lines) confirm the pushes carry the reader's own serial and resolve to its assigned row, so this is **the physical reader decoding, not a network source**. **Diagnosis:** the scan engine ships with many 1D symbologies enabled, some with weak/no checksums. Six-digit all-numeric strings are the signature of **Interleaved 2-of-5** (even-length, digits-only, no checksum — any high-contrast stripe pattern of the right proportions "decodes"); a lone `C` is a **Code39/Codabar** artifact (Codabar start/stop chars are A–D). Low sun creates exactly such patterns at a gate: the striped barrier arm, fence/railing shadows sweeping as the sun moves, glare bands. RFID noise would instead give repeating UID-shaped values. **Impact: noise, not risk.** Every phantom was REFUSED fail-closed; a phantom can never match a ticket ([[ticket-encoding]] ids are 11-digit + Luhn, so a 6-digit read has nothing to match). **Feed filter (2026-07-04 — supersedes the earlier "do not filter" position).** Initially each phantom signed an `exit.refused.noSession` anomaly (#52–58 in the feed) and the position was to keep it that way. The operator overruled it, correctly: red "who is trying to exit?" rows for NOBODY train the operator to ignore the signed feed — alarm fatigue is the adversary's friend. `read-dispatch.ts` now drops a no-match value that **cannot possibly be a credential we issue** to UNSIGNED telemetry (`device_events`, `unrecognizedRead:true` — still auditable). "Possibly ours" is deliberately WIDE and everything in it still signs the normal refusal anomaly: Luhn-valid ticket shapes (a forged ticket is a real probe), `SUB-`/`SUBSESS-` prefixes, ANY read on a confirmed-RF channel (a physical card is a real event, never sun noise), and plates (never shape-filtered). The filter also works pre-prefix (legacy untagged reads). Still fix at the source too: **Fix (vendor tool, per reader — config lives ON THE DEVICE, not in our DB):** disable every symbology except **QR + Code128** (all our credentials); if offered, set **minimum decode length ≥ 10** and require checksums. Apply to BOTH readers. ⚠️ A factory reset or a swapped unit silently re-enables the phantom symbologies — re-apply after any reset/replacement. Physical fallback if any noise survives: hood/visor the window, tilt it down, avoid facing the striped arm. ## ⚠️ Two units, two card sets, no overlap — 125 kHz vs 13.56 MHz (2026-09-17, unresolved) The product page says the DT-008 reads "ID/IC/NFC cards" and the **box leaflet** ([[dingtian-dt008-box-manual]]) claims EM-ID, M1, ISO 14443A/B and ISO 15693 in one unit. Yet on the bench 2026-09-17, with two card sets, the two units we own read **disjoint** sets: | Unit | Serial family | Reads | Does not read | | --- | --- | --- | --- | | park-buzi entry/exit (bought 2026-06) | `H05M…` (`H05M2AFA`, `H05MA5B0`) | the site's enrolled cards (**125 kHz "ID"**, EM4100-class) | 13.56 MHz cards | | lab unit (fresh, 2026-09) | `HC002721` | **13.56 MHz "IC/NFC"** cards (e.g. UID `A238BC`) | the park-buzi card set | **The decisive test needs no hardware:** hold each card on an NFC-capable phone. A 13.56 MHz card is detected; a **125 kHz card is invisible to a phone**. The lab reader and the phone agreed on exactly the same set, and the other set was invisible to both — so the park-buzi set is 125 kHz and the park-buzi readers are the 125 kHz variant. Card bodies help too: EM4100 / TK4100 / T5577 (often a printed 10-digit decimal) = 125 kHz; Mifare / S50 / 1K / NTAG = 13.56 MHz. Nothing in `QRCode_v1_6_5.exe` selects the frequency (no card-type field — see the screenshot in [[site-device-installation]] §2). **Why the lab unit does not read them is NOT settled** — the phone test only proves the park-buzi cards are *not* 13.56 MHz. Three explanations remain, with different fixes: 1. **The park-buzi cards are 125 kHz but not EM4100** (HID Prox / Indala / AWID / a T5577 in a non-EM format): invisible to a phone, not decoded by an EM-only front end, but read by the older batch. Card bodies help: EM cards usually print a 10-digit decimal; HID cards carry the HID logo. 2. **The lab unit's 125 kHz front end is dead or disabled** — the leaflet says it should be there; a firmware setting the v1.6.5 tool does not expose is possible. 3. **The leaflet is generic and units ship per variant** — the vendor can say from the two serials. **Decisive test (cheap):** a known **EM4100 125 kHz card/keyfob** on the lab unit, held at 1–10 cm. Reads → its 125 kHz radio works and the park-buzi cards are a different 125 kHz format (→ 1). Does not read → unit defect or variant (→ 2/3, vendor with the serial). A USB keyboard-wedge EM4100 reader (~10 €) additionally says outright whether the park-buzi cards are EM4100. **Consequences (hold regardless of which explanation wins)** - **A site's card stock and its readers must be proven together.** A card enrolled at park-buzi is not readable by the lab unit today, whatever the reason; a replacement reader must be tested against the site's actual cards **before** it ships, or every enrolled card is orphaned — same class of trap as the `Card Input format`. - **Purchase spec must name the card technology and format** the site uses (the serial family is only a hint: `H05M…` reads park-buzi's cards, `HC…` does not). Ask the vendor (support address in the tool's title bar) which card types a given serial decodes. - **Bench testing park-buzi card problems on the lab unit is meaningless** until the lab unit is shown to read the site's card type. - **Open:** with a 13.56 MHz unit the native UID is 4 or 7 bytes, so `Card Input format = 6H` truncates it — check on the lab unit which bytes survive and whether two cards can collide on the 6-hex value before enrolling anything against a 13.56 MHz reader ([[open-questions]]). Record the variant on the site record next to the serial ([[site-device-installation]] §"Record"). **A phone is not a card (2026-09-17).** Tapping a phone on the 13.56 MHz unit beeps and logs a *different* id every time (`18CA08`, `37F108`, `D5A908` three seconds apart). Read backwards those are `08 CA 18`, `08 F1 37`, `08 A9 D5`: a first UID byte of **`08`** is the ISO 14443 marker for a **random UID**, which every phone in card-emulation mode generates per tap so that readers cannot track the handset. So a phone can never be enrolled as an RF credential, and a phone tap in the logs is not a clone attempt — just noise with a fresh id each time. Same for cards with a "random ID" feature (DESFire / Mifare Plus in random-UID mode): if a card ever enrolls but "stops matching", check whether its id changes between taps. Incidentally this shows what **`6H` does on a 13.56 MHz unit**: the tool prints the **first three bytes of the 4-byte UID, byte order reversed, fourth byte dropped**. Confirm against a card with its UID printed on the body before enrolling; the dropped byte is the collision risk in [[open-questions]] #18. ## Bench sink — `scripts/reader-sink.py` (2026-09-17) A stdlib-only Python HTTP server that answers the push on any `/qa/mcardsea.*` path with the SDK verdict (`--accept` → status 1 / two beeps, default status 0 / one beep), `Connection: close`, and prints one line per read: time, source IP, `serial`, `dev`, `dir` (from the `status` low digit), `ch` (from the `Q:`/`K:` prefix), `cardid`, path. Point the reader's *Server address / Server Port* at the laptop (`python3 scripts/reader-sink.py -p 3000 --accept`, port 80 needs admin rights). Use it to see the raw `cardid` a card yields, to prove a reader pushes at all, and to time the beep against the reply. No app, no DB, no Docker. ## ⚠️ Reply MUST set `Connection: close` (verified on hardware) The reader sends `Connection: keep-alive` but **only acts on the verdict (beep/output) once the TCP socket CLOSES**. Fastify's default keeps the connection alive → the reader waits out a **~10 s keep-alive timeout before beeping**, even though the server replied in ~15 ms. Every vendor demo replies **`Connection: close`** and shuts the socket. Fix: the endpoint sets `reply.header("connection","close")`. Symptom if regressed: correct accept/reject but a ~10 s lag before the beep. (The request arrives fast; the delay is entirely the reader waiting for close.)