--- type: reference tags: [parking, runbook, installation, devices, network, field] sources: [] updated: 2026-10-08 --- # Site device installation — know it BEFORE you are standing in the booth A field runbook: for every device we deploy, its **factory address and credentials**, the **tool** you need, **what the app configures by itself** at assign time versus **what must be done by hand on the device**, and the **traps already paid for** on park-buzi and the lab. The [[appliance-provisioning]] runbook covers the booth PC (OS, disk, Docker, Periphery); this page covers everything plugged into it. Written 2026-09-09 after an evening lost to a printer whose factory address nobody had written down ([[k200l-printer]]). Rule of thumb that explains most of this page: **every field device ships on its own private subnet with DHCP off, and none of them announce themselves.** You bring a laptop that can take a second static address, you put it on the device's factory subnet, you move the device to the site plan, and only then does anything else see it. ## Before leaving the office **Bring** - A laptop with an Ethernet port and the right to add a **second static IPv4 address** to it (Windows: adapter → IPv4 → Advanced → add). Under WSL, remember the source-address bug ([[wsl-dev-networking]]): after adding a temporary address, `ping` may work while HTTP times out. - The Dingtian reader tool **`QRCode_v1_6_5.exe`** (Windows) **or `scripts/dingtian_qr.py`** (Python 3, runs on the booth itself — see [[dingtian-qr-linux-tool]]) for a DT-008's IP, server target, output type, prefixes and card format. Symbologies are set in neither (no known path). A browser is enough for everything else. - Patch cables, a USB A–B cable (printers), the site's **address plan** (below) filled in, the app **admin** password, and a fresh Komodo **onboarding key** if the booth PC is new ([[appliance-provisioning]] §7a). - The **serials** if already known: DT-008 `cjihao` (on the reader's label / in the tool), camera MAC/serial, printer model (label on the bottom — the K200L's own web UI calls it "POS-80"). **Address plan** — the device VLAN ([[network-isolation]]) is `10.0.10.0/24` on both sites so far, **every device static, DHCP off everywhere**. The convention from park-buzi / park-lab: | Address | Device | Factory address it came from | | --- | --- | --- | | 10.0.10.1 | VLAN gateway (switch/router) | — | | 10.0.10.5 | [[dingtian-relay]] board (barriers + inputs) | `192.168.1.100` | | 10.0.10.7 / .8 | [[dingtian-dt008-reader]] entry / exit (**unique IP each**) | `192.168.1.99` | | 10.0.10.9 | entry-dispenser printer (park-buzi: Cashino KP-300H) | *not recorded — fill in* | | 10.0.10.10 | booth-receipt printer (park-buzi: [[rongta-printer]]) | *not recorded — fill in* | | 10.0.10.11 / .7 (lab) | [[k200l-printer]] | `192.168.123.100` | | 10.0.10.12 / .13 | [[lpr-camera]] entry / exit (Hikvision DS-2CD1047G3H-LIU) | `192.168.1.64` (Hikvision default; needs activation) | | 10.0.10.203 | the booth PC on the device VLAN (**the `backendIp` every device pushes to**) | — | Fill the real numbers into the site record before you drive; the wizard asks for the booth's push address once and writes it into the Dingtian and the cameras. ## 1. Dingtian relay board (DT-R004 family) — barriers, button, radar **Factory:** IP `192.168.1.100`, web UI on port 80, login `admin` / `admin`, UDP `60000` (binary) / `60001` (string), multicast discovery `224.0.2.11:60000`. See [[dingtian-relay]]. **By hand, on the device (browser at its factory address):** set the site IP / mask / gateway in the Network page and reboot. That is the only thing you *must* do by hand. Optional but recommended: in the web UI **disable the UDP2 "string" protocol** (a password-less relay-fire path); the app's harden step tries to disable it and **warns if the device refused** — then do it here. **Wiring:** button on **I1** (NO contact to GND, idles HIGH, pulls LOW on press); radar dry contact on **I2**; barrier operator's open input on **relay 1** (entry) and **relay 2** (exit); a spare relay for the entry button lamp ([[button-light-indicator]]). One board can carry both barriers; two distant barriers = two boards ([[entry-exit-points]]). **What the wizard does on assign** ([[first-run-setup]], [[device-input-flow]]): finds the board by multicast ("Scan for controllers" — laptop/booth must share the L2 segment), checks and clears `input_link_relay` (factory default auto-fires a relay from its input — the app must decide, not the board), sets a random **relay password** (UDP binary), disables every other control channel, rotates the web login, and writes the **input push** URL + per-device Digest credentials so button/radar edges reach the booth PC. You enter the relay map (which relay is entry/exit/both) and the inputs (button → its relay; radar → `presence`, `activeLow` if it idles opposite the button — [[hikvision-radar]]). **Traps** - The HTTP CGI API is **unauthenticated** on this firmware; `admin/admin` gates only the web page. Never enable `session_en` — it bricks the config API and only a **factory reset** recovers. The VLAN is the boundary, not the login ([[dingtian-relay]] §Hardening). - A relay password mismatch shows as **"offline despite ping"**: the status query is answered only with the right password. Re-assign / re-enter the relay password in the device form. - "Relay test" in Setup pulses real hardware and signs a ledger event — use it to prove wiring, once per relay. ## 2. Dingtian DT-008 QR + RFID readers **Factory:** IP `192.168.1.99`; no web UI — everything is set over the network with **`QRCode_v1_6_5.exe`** (Windows) or **`scripts/dingtian_qr.py`** (any OS; same UDP protocol, reversed 2026-10 — [[dingtian-qr-linux-tool]]). See [[dingtian-dt008-reader]]. **From the wizard (app builds after 2026-10-08):** add a reader → **Skano LAN-in / Scan the LAN** lists every DT-008 on the device VLAN with its mode and current server; **Use** fills serial + IP; **Test** says whether it is in HTTP mode and whether the serial matches; **Save** switches it to HTTP and points its server at this booth (items 2 and 6 below, done for you). Items 1, 3, 4, 5 are still manual (IP via `set-network`, prefixes/card format via `set`, both in `scripts/dingtian_qr.py`; symbologies only in the exe). Needs the reader's IP in the form — with it blank the save warns and configures nothing. **By hand (vendor tool, or `scripts/dingtian_qr.py` from the booth), per reader:** 1. **Unique device IP** (`.7` entry, `.8` exit). Two readers on one IP was the 2026-06-18 "wrong barrier" incident — scans land on the wrong device row. 2. **Output type = `HTTP`** (the tool also offers RS232 / WG26 / WG34 / RS485 / USB keyboard / USB serial — in any of those the reader beeps locally and never contacts the booth), **Server IP = THIS site's booth** (park-2 is `10.0.10.101`; `10.0.10.203` is the lab — never copy it), **server port** = the booth's HTTP port (80 behind the prod proxy); "server language" can stay whatever it is (php/jsp/asp/aspx/cgi are all served — the reader GETs `/qa/mcardsea.`). 3. **Output prefixes:** `QRCode Output Prefix` = `Q:`, `Card Output Prefix` = `K:` (channel tagging — a printed clone of a card cannot pass as the card). 4. **Card Input format = `6H`** (defines the UID shape enrolled; changing it later orphans every card). 5. **Symbologies: QR + Code128 only**, minimum decode length ≥ 10, checksums on — otherwise low sun through the striped arm produces phantom 6-digit reads (park-buzi, July). 6. Note the **serial (`cjihao`)** — the wizard binds the reader by serial, not by IP. **In the wizard:** add the reader with its serial, bind it to the controller relay it sits at (direction is inherited from the relay). **Verify:** scan a card — the server log shows `READ serial=… → device=… verdict=… dir=…`; the reader beeps **twice** on accept, once on refuse, and only after the server's reply (no reply = no beep, the scan still happened). **From the booth, no Windows (2026-10-08):** `get` / `set` are unicast UDP, so they run on the booth host over SSH (Python 3 is on every booth; the server container has none): ``` scp scripts/dingtian_qr.py :/tmp/ && ssh python3 -I /tmp/dingtian_qr.py get 10.0.10.7 ssh python3 -I /tmp/dingtian_qr.py set 10.0.10.7 --output-type 3 # item 2: HTTP mode ``` `get` prints every field above by name (`output_type`, `server`, `server_port`, `card_input_format`, `qr_prefix`, `card_prefix`…). `set` changes only the fields given and re-sends the rest as read. Only `discover` / `set-network` need the L2 broadcast (run them on the booth, not across Netbird). **Trap:** a factory reset or a swapped unit silently loses items 3–5. Re-apply all of them. **Trap (park-2, 2026-10-08): "it beeps, so it works" is false.** Enrolling a card failed on both readers although each beeped. The booth log held **zero** `/qa/mcardsea` requests over 21 h and the capture window saw only the form's own polls: the readers never contact the booth at all. A beep without a `READ` line in the log means the reader is **not in HTTP mode or points at another server** — fix it on the reader (item 2), nothing in the app or the wizard can. Diagnose in one command on the booth: `docker logs --since 1h 2>&1 | grep -c mcardsea` while a card is presented — `0` = reader-side; then **read the reader itself** with `dingtian_qr.py get` (above). park-2's answer: both readers `output_type = WG26` (server `10.0.10.101:3000`, JSP, 6H, no prefixes) — they were left in Wiegand mode at install, so every scan went to a Wiegand line nobody is listening on. (Port 3000 is fine: the host-net server listens there directly; 80 via Caddy works too.) Fix = `set --output-type 3` per reader, then re-run the enrolment. **Trap (2026-09-17): two DT-008 units read disjoint card sets.** park-buzi's units (`H05M…`) read the site's 125 kHz cards and the fresh lab unit (`HC002721`) reads only 13.56 MHz cards, although the box leaflet claims both. Batch variant, a dead 125 kHz front end, or a non-EM 125 kHz card format — unresolved. Rule until it is: **test a replacement reader against the site's actual cards before it ships**, and record the site's card technology. Quick sort of a card: an NFC phone detects 13.56 MHz, cannot see 125 kHz. Details: [[dingtian-dt008-reader]] §"Two units, two card sets". **Identify what a reader can read — before it ships (2026-09-17).** Keep a **reference kit** in the lab: one known EM4100 125 kHz fob, one known Mifare Classic (M1) card, and a phone with NFC. Tap all three on the unit with the tool's log pane open (or [[dingtian-dt008-reader]] §Bench sink): a line per tap = that technology decodes. The phone always beeps on a 13.56 MHz unit with a random `08…` id (never a credential, but proves the 13.56 MHz radio). Then tap **the site's own cards**. Write the result on the site record next to the serial (`reads: EM4100 | M1 | both`). Serial families are only a hint (`H05M…` read park-buzi's 125 kHz cards, `HC…` did not); the vendor can confirm from a serial. A unit that fails the site's cards does not leave the lab. **Parameters per card technology** — identical except one field: | | 125 kHz site (park-buzi today) | 13.56 MHz site | | --- | --- | --- | | Card Input format | **`6H`** (what park-buzi's cards are enrolled with — never change on a live site) | **`8H`** preferred: the native UID is 4 bytes, `6H` drops one and two cards can collide — confirm `8H` on the lab unit before the first enrolment ([[open-questions]] #18) | | Output prefixes | `Q:` / `K:` | `Q:` / `K:` | | Output type / server | HTTP, booth IP, booth HTTP port | same | | Buzzer | On (the operator hears accept/refuse) | On | | Symbologies | QR + Code128 only | same | | Card stock | EM4100 (or whatever the reference test showed) — do not mix | Mifare Classic UID-based; note that a phone is never a card | A site is one technology: once cards are enrolled the reader batch, the input format and the card stock are frozen together. Migrating means re-enrolling every credential. **The tool's Setting tab (v1.6.5, seen 2026-09-17):** *Search device* lists units by serial; *Get parameter* loads one. *Network parameter*: IP / Netmask / Gateway / DNS1 / DNS2, DHCP (Static IP), **Server address / Server Port / HTTP Server Language**, its own *Set* button. *Format parameter*: Output type `HTTP`, **Card Input format** (`6H`), QRCode Output format/prefix/suffix, **Card Output format/prefix/suffix** (prefix fields are where `Q:` / `K:` go), serial baud/bits greyed out under HTTP, Low/High Pulse, its own *Set*. *External parameter*: Restart interval (12 h), Work mode (Normal), **Buzzer On/Off**, Scan code fill light, its own *Set*. Each group is written by **its own Set button** — setting the network and forgetting the format *Set* is easy. The log pane at the bottom echoes every card read by the tool (`… A238BC`), which is the quickest "did the radio see it" check. The *Test device* tab is the read monitor. Symbology selection was not found on this tab — locate it on the *Test device* tab or in a newer tool before relying on item 5. ## 3. Hikvision camera (DS-2CD1047G3H-LIU, AcuSense) — ANPR + snapshots **Factory:** `192.168.1.64`, **inactive** until a password is set on first boot (browser at that address or the SADP tool); after activation the login is `admin` / the password you chose. Site convention so far: `admin` / `admin123` on the first units (change per site and record it). See [[lpr-camera]]. **By hand, on the camera:** 1. Activate, set the site IP, disable DHCP. Time: NTP off-site is unavailable — the app re-syncs the camera clock from the booth at every offline→ready edge ([[clock-integrity]]). 2. **Streams:** the snapshot the app pulls MUST come from the **sub stream** (`102`) — the main stream's ISAPI snapshot returns **503 instantly, always, on this model**. Set the sub stream to the highest resolution the camera allows. **Set the sub stream's video encoding to MJPEG** — the booth camera tiles stream it live ([[camera-live-view]]); with H.264 the tile stays on the snapshot and says why. The `102` snapshot still returns a JPEG after the switch (measured on the G2 line, 2026-11-17). With the snapshot stream on Sub, its resolution is also the ANPR resolution (MJPEG on the G2: 640×360, 640×480 or 1280×720). 3. **Event push:** Event → Motion Detection with the AcuSense **Detection Target = Vehicle** filter ON, "Notify Surveillance Center" on, then Alarm Settings → **Alarm Server** → `http://10.0.10.203/api/devices/hikvision//event`. The `deviceId` exists only after the wizard assign, so: **assign first, then come back to the camera**. Digest user/password if the firmware allows it (the wizard shows them). 4. "Enable Hikvision-CGI" is a different legacy surface — **not** needed for ISAPI. 5. **Close the web UI / live view when done.** The camera has few connection slots; a browser left open makes every snapshot pull 503 "Device Busy" ([[lpr-camera]] §503). **In the wizard:** driver `hikvision`, host, `admin` password, channel 1, **stream = Sub**, ANPR on, bind to the relay at that barrier, `alarmPushEnabled` on. **Verify, do not assume:** drive a car through and look at `GET /api/events` (or the log) for an alarm with `targetType=vehicle`. A camera configured for push that has sent **zero** alarms is broken on its side: pull its *Diagnose Information*; `Main Db is broken` means a corrupt config database → **factory reset**, then redo 1–3 (the Vehicle target filter defaults OFF after a reset). Point the Alarm Server at a dumb HTTP sink on the laptop if you need to see the verbatim body ([[lpr-camera]] §"auto-enter but not auto-exit"). **If the camera is a Dahua** (first unit inspected 2026-09-17, [[dahua-ipc-hfw2549t]]): factory `192.168.1.108`, `admin` + a password set at first boot, web UI on port 80 (HTTPS off by default on the bench unit). In the wizard: driver `dahua`, host, `admin` password, **channel 1 as printed** (the driver sent `channel=0` → HTTP 400 until 2026-09-17; fixed). There is no HTTP Alarm Server to point at the booth: events would be read by the server holding an `eventManager.cgi?action=attach` stream (**not built yet** — a Dahua today gives snapshots + clock sync only, no lane busy/free and no ANPR bridge), so no "assign first, then go back to the camera" step — but SMD must be set to **Vehicle** on the camera. Set the time zone by hand; the app re-syncs the clock from the booth like it does for Hikvision (the bench unit ran 1 h behind with DST off; NTP is useless on the isolated VLAN). Five wrong logins lock `admin` for 5 minutes — check the password with one `curl --digest` before assigning. ## 4. Radar (vehicle presence at the entry barrier) A dry-contact sensor into a Dingtian input, nothing on the network. Check with the board's input status (`00` query → `relays:inputs`) whether it **idles HIGH or LOW**; if it idles opposite the button, set `activeLow` on that input in the wizard, or the gate inverts (tickets only when the lane is empty). It is advisory: it gates the button, it never opens anything ([[hikvision-radar]], [[entry-double-press]]). ## 5. Printers — three models, one byte stream, different status All print the same ESC/POS bytes over **raw TCP 9100** or **USB (`/dev/usb/lpN`)**; what differs is whether the app can see paper/cover state ([[printer-status-monitoring]], [[printer-usb-transport]]). Roles: **entry-dispenser** outside at the lane, **booth-receipt** inside (receipts, subscription cards, Z-reports, and the backup for entry tickets), **wash-desk** if the site has a Car Wash ([[printer-roles-failover]]). Higher `failoverRank` = tried first. | Model | Factory network | Config UI | App driver | Live status | | --- | --- | --- | --- | --- | | [[k200l-printer]] (Xprinter/ICS K200L, "POS-80" board; **the park-buzi unit**) | `192.168.123.100/24`, DHCP off | browser, port 80, no login: Configuration → fixed IP → Save → Restart | **`k200l`** | over LAN: cover / paper / cutter / off-line from `/prt_status.htm`; over USB: reachability only | | [[rongta-printer]] (RP-series) | *not recorded — fill in* | status page `/prn_stat.htm` on port 80 | `rongta` | over LAN: full; USB: reachability | | Cashino KP-300H | *not recorded — fill in* | *not recorded* | `escpos` (generic) | reachability only, by design — no trustworthy status source | **Prefer LAN over USB** wherever a cable can reach: the booth sees a real amber "cover open, paper out" while a roll is changed, and the `usblp` path (udev rule, node renumbering, the park-buzi "offline after reload" mystery) drops out of the picture. USB needs the appliance's `usblp` + udev rule ([[printer-usb-transport]] §Provisioning) and the printer shows up as `/dev/usb/lpN`, numbered by plug order. **Verify:** the wizard's "Test" only *probes* (opens the port / the device node) — it prints nothing. Print something real: a subscription with a QR credential auto-prints its card and has a **Reprint card** button; a payment prints a receipt; a wash till prints slips. Check the Cashino's barcode with a real ticket (the KP-300H garbled overflowing barcodes until the geometry fix). ## 6. Order of work on site 1. Address plan on paper; VLAN ports patched; booth PC up with its device-VLAN address. 2. Dingtian: factory address → site address (browser) → wire button, radar, barriers. 3. Wizard: **controllers first** (the relay map + inputs); "Relay test" each barrier. 4. Readers: tool (IP, server, prefixes, format, symbologies) → wizard (serial, bind) → scan test. 5. Cameras: activate → IP → sub stream → wizard assign → Alarm Server + Vehicle target → drive-through test → close the browser. 6. Printers: site address → wizard (role, rank) → print a card. 7. Walk-through: button + radar → ticket; QR entry then exit; RFID; a subscriber's plate at the camera; pay at the booth → receipt → exit; paper reload on each printer while watching the footer. 8. Record in the site record: every IP, serial, camera password, printer model, which relay is which, photos of the labels. Remove the temporary laptop addresses. Log out of every device UI. ## 7. Reaching the cameras remotely — port forward through the booth host (park-2, 2026-10-08) park-buzi exposed its two Hikvision web UIs on the site router (`park-buzi.msai.al:8081` / `:8082`, see [[lpr-camera]]). park-2 does the same **through the booth host**, because its router only knows the 192.168.1.0/24 side while the cameras live on the device VLAN: | | address | | --- | --- | | router / internet side | `eno1` 192.168.1.101, gateway 192.168.1.1, public 91.230.255.154 | | device VLAN side | `eno1` 10.0.10.101 (same NIC, second address) | | Netbird | `wt0` 100.75.7.237 = `park-2.nb.infra` | | entry camera | 10.0.10.9:80 → published as **8081** | | exit camera | 10.0.10.10:80 → published as **8082** | Done with iptables on the host (needs root; the admin account has no passwordless sudo). `ip_forward` is already 1 because Docker set it. Docker also sets the FORWARD policy to DROP, so the explicit ACCEPTs are mandatory, and the SNAT is what brings the camera's replies back through the host (the cameras' gateway is not the booth): ```bash iptables -t nat -A PREROUTING -p tcp --dport 8081 -j DNAT --to-destination 10.0.10.9:80 iptables -t nat -A PREROUTING -p tcp --dport 8082 -j DNAT --to-destination 10.0.10.10:80 iptables -t nat -A POSTROUTING -p tcp -d 10.0.10.9 --dport 80 -j SNAT --to-source 10.0.10.101 iptables -t nat -A POSTROUTING -p tcp -d 10.0.10.10 --dport 80 -j SNAT --to-source 10.0.10.101 iptables -I FORWARD -p tcp -d 10.0.10.9 --dport 80 -j ACCEPT iptables -I FORWARD -p tcp -d 10.0.10.10 --dport 80 -j ACCEPT iptables -I FORWARD -m conntrack --ctstate ESTABLISHED,RELATED -j ACCEPT apt install -y iptables-persistent && netfilter-persistent save # survive reboots ``` - **Reach:** from any Netbird peer with a policy to park-2, `http://park-2.nb.infra:8081/` (no router change needed). From the internet only once the router forwards 8081/8082 to 192.168.1.101. PREROUTING does not apply to the host's own traffic — test from another machine. - **Netbird-only variant:** add `-d 100.75.7.237` to the two PREROUTING rules; then the public forward can never reach the cameras even if someone adds it on the router. - **Undo:** the same lines with `-D`. **ufw**, if ever enabled there, also needs `ufw route allow proto tcp to 10.0.10.9 port 80` (and `.10`). - **Why not Docker:** `docker run -p 100.75.7.237:8081:80 alpine/socat …` would do the same without sudo, bound to the overlay only; the user chose the iptables route. - This is a deliberate hole in [[network-isolation]] (camera web UI reachable off the VLAN); the camera's own digest auth is the only gate behind it. Keep the public side off unless needed; prefer the Netbird path. ## Gaps to fill next time you hold the hardware - Factory address and configuration tool of the **Cashino KP-300H** and the **Rongta RP** units (both still unknown here). - Where in `QRCode_v1_6_5.exe` the **symbologies** are selected (the Setting tab has no such field; the IP / server / prefix fields are now described in §2). - The **card technology** each site uses and which reader batch reads it, on the site record next to the serial; and the result of the EM4100 test on the lab unit. - Whether the camera activation was done with SADP or the browser at park-buzi, and the per-site camera password location. - Where the **site record** lives (a page per site under `wiki/entities/`? — park-buzi and park-2 have none yet; the Komodo stack env is the closest thing). Related: [[appliance-provisioning]] · [[first-run-setup]] · [[device-registry]] · [[network-isolation]] · [[entry-exit-points]] · [[dingtian-relay]] · [[dingtian-dt008-reader]] · [[lpr-camera]] · [[hikvision-radar]] · [[k200l-printer]] · [[rongta-printer]] · [[printer-usb-transport]] · [[wsl-dev-networking]] ## Booth host firewall: what the device net must reach (2026-10-22) Found at park-lab (ufw active, rules root-only): the device VLAN could reach ssh but **not** the app. Devices need, from the device subnet to the booth: | Port | Who | Why | | --- | --- | --- | | **3000/tcp** (`PORT`) | [[dingtian-relay]] input push, any device push | `backendPort()` advertises the server's own port, **not** Caddy's 80 — the push bypasses the proxy. | | 80/tcp | admins on the LAN | Caddy → operator UI (and `/health`). | `sudo ufw allow from 10.0.10.0/24 to any port 3000 proto tcp` (and 80). Without 3000 the booth's assign flow *succeeds* (it configures the device outbound) but every button push then dies with a timeout — a silent failure. The booth's ufw rule set is not yet captured in [[appliance-provisioning]]; it should be.