--- type: entity tags: [parking, hardware, camera, dahua, snapshot, events, bench] sources: [] updated: 2026-09-17 --- # Dahua IPC-HFW2549T-AS-IL — the lab bench unit (inspected 2026-09-17) A 5 MP Dahua WizSense bullet (`IPC-HFW2549T-AS-IL-0360B`, 3.6 mm, "IL" = smart dual illuminators), firmware **`V2.880.0000000.22.R`, build 2026-05-14**, serial `9J0E4EFPAGECB23`, MAC `fc:5f:49:48:42:ac`, processor SSC378Q. Sits on the bench at `10.0.10.11`, login `admin` / the lab password. **It is not an ANPR camera** — plates come from the host-side [[opencv-anpr-service]] off its snapshot, exactly as with the Hikvision units. Everything below was read off the unit over its CGI with `curl --digest`; nothing was written to it. **It is not factory-fresh.** Hostname `DAHUA_PORTA_KRYESORE` ("main gate"), an Alarm Server already pointed at `10.7.8.9:8888`, DNS `8.8.8.8`, SMD tuned to vehicles only — this unit was configured for a gate somewhere before it reached the bench. Treat its settings as inherited, not defaults. ## What the CGI surface gives us | Need | Endpoint (all HTTP Digest, port 80; 443 is **off**) | Result on this unit | | --- | --- | --- | | identity | `magicBox.cgi?action=getSystemInfo` / `getSoftwareVersion` / `getSerialNo` / `getVendor` | model, firmware, serial, `vendor=Dahua` | | snapshot | `snapshot.cgi?channel=1` | 200, `image/jpeg`, **2880×1620**, ~270 KB, ~0.5 s | | snapshot channel `0` / `2` | same | **400** — the channel index is **1-based**; `subtype=1` is ignored (still 2880×1620) | | clock read | `global.cgi?action=getCurrentTime` | `result=2026-09-17 09:03:50` | | clock write | `global.cgi?action=setCurrentTime&time=YYYY-MM-DD%20HH:MM:SS` | 200 `OK`; read-back matches within 1 s (**verified**, now the Dahua clock-sync) | | events | `eventManager.cgi?action=attach&codes=[All]&heartbeat=5` | 200, `multipart/x-mixed-replace`, a `Heartbeat` part every N s, event parts in between | | event caps | `eventManager.cgi?action=getCaps` | snapshot/record/mail/alarm-out linkage; no HTTP push cap | | streams | RTSP 554 `cam/realmonitor?channel=1&subtype=0` / `1` | **H.265** Main 2880×1620 @ 20 fps; sub 704×576 @ 20 fps (probed with ffprobe) | | ports | 80 (HTTP), 554 (RTSP), 37777 (Dahua SDK/DHIP) open; 443, 37778, 5000, 8000 closed | | ### Snapshot: the driver decremented the channel — this unit said no (fixed 2026-09-17) `dahuaDriver` (`packages/devices/src/drivers/camera.ts`) builds `/cgi-bin/snapshot.cgi?channel=${ch-1}` on the note "Dahua channels are 0-based". On this firmware `channel=0` → **HTTP 400**, `channel=1` → the JPEG. Dahua's HTTP API numbers `snapshot.cgi` and `realmonitor` channels from 1 (only the `configManager` *tables* are 0-indexed — the usual source of the confusion). So an admin who enters "channel 1" in the wizard gets a permanent **degraded "HTTP 400"** from `healthCheck()` and no snapshot ever. The Dahua driver was never run against hardware before today ([[lpr-camera]] §Verified only covers Hikvision). **Fixed the same day**: the driver now sends the channel as entered (clamped to ≥1) and `camera.test.ts` pins the URL. The fixed driver was then run against this unit: `healthCheck` → ready (≈256 KB), `captureSnapshot` → `image/jpeg`, 273 KB, JPEG magic. The snapshot always comes off the **main** stream at full resolution — there is no per-stream snapshot as on Hikvision, and `subtype` on `snapshot.cgi` is ignored. Fine for us: the app re-encodes to 1280 px on capture ([[snapshot-storage-optimization]]) and the recognizer keeps the full frame. ### Events: Dahua PULLS-with-a-held-socket, it does not HTTP-POST Dahua has an "Alarm Server" too (`configManager.cgi?action=getConfig&name=AlarmServer`), but its protocol is **`DAHUA`** (proprietary, port 8888) — not the Hikvision-style HTTP POST that `routes/hikvision-alarm.ts` consumes. The HTTP way to get events is the **subscription stream**: the host opens `eventManager.cgi?action=attach&codes=[SmartMotionVehicle,CrossLineDetection,…]&heartbeat=5` and keeps it open; the camera writes one multipart part per event (`Code=…;action=Start|Stop;index=…`) and a `Heartbeat` part every 5 s. Verified on the bench: the stream stays up, heartbeats arrive, Digest auth applies to the attach. This inverts the Hikvision model: - the camera never needs to know the booth's address — no `pushesToBackend`, no "assign first, then go back to the camera" step, no source-IP guard, and the WSL mirrored-mode source-IP problem does not exist; - the **server** owns the connection: reconnect with backoff, treat a missing heartbeat as camera-offline, one long-lived socket per Dahua camera; - vehicle events come from **SMD** (`SmartMotionDetect`: `Enable=true`, `ObjectTypes.Vehicle=true`, `Human=false` on this unit — inherited, and exactly the "Detection Target = Vehicle" the Hikvision runbook step asks for) → code `SmartMotionVehicle`; tripwire/intrusion (`CrossLineDetection`, `CrossRegionDetection`) with `ObjectTypes=Vehicle` are the IVS equivalents, **none configured** on this unit (only disabled FaceDetection and HeatMap rules exist). **Verbatim event parts captured** on a 25-minute `codes=[All]` listen (bench motion + the clock write below). Each part is `Content-Type: text/plain` with a `Code=…;action=…;index=…;data={JSON}` body: ``` Code=VideoMotion;action=Start;index=0;data={ "EventID" : 31927, "Id" : [ 0 ], "RealUTC" : 1789634136, "RegionName" : [ "Region1" ], "SmartMotionEnable" : true, "WithSnap" : true } Code=VideoMotion;action=Stop;index=0;data={ …same EventID… } Code=VideoMotionInfo;action=State;index=0;data={ "RealUTC" : 1789634137, "WithSnap" : false } Code=TimeChange;action=Pulse;index=0;data={ "BeforeModifyTime" : "17-09-2026 09:35:51", "ModifiedTime" : "17-09-2026 10:35:49", "RealUTC" : 1789637749, "WithSnap" : false } ``` - `action=Start` / `Stop` with a shared `EventID` is the busy/free edge (the Hikvision `active`/`inactive` equivalent); `VideoMotionInfo State` is a per-second chatter part to ignore. - The motion arrived as plain `VideoMotion` with `SmartMotionEnable: true`, **not** as `SmartMotionVehicle` — whether the SMD filter suppresses `VideoMotion` for non-vehicles, or only adds the `SmartMotion*` codes on top, is **unconfirmed** (nobody drove a car past the bench). Subscribe to both and log which fires before gating anything on it. - **`RealUTC` is the camera's *belief* of UTC, i.e. its wall time minus its configured offset.** After the clock write it read 09:35:49 for a real 08:35:49 UTC (UTC+1, DST off). Never use it as an absolute time — stamp events on receipt from the booth clock, as the Hikvision route does. - `TimeChange` is emitted for our own clock sync; harmless, but filter it from any "activity" view. ### Clock: one hour behind, NTP off — clock-sync built the same day `getCurrentTime` returned 09:03 while the bench wall clock read 10:03 CEST: `NTP.Enable=false` (address `time.windows.com`, unreachable on an isolated VLAN anyway), `NTP.TimeZone=1` (Belgrade) and **`Locales.DSTEnable=false`**, so the unit runs at UTC+1 year-round. The Hikvision units get their clock from the booth at every offline→ready edge ([[clock-integrity]]); until today the Dahua driver did not claim `isClockSyncable`. Now `DahuaCamera.syncClock` (camera.ts) reads `global.cgi?action=getCurrentTime` (`result=YYYY-MM-DD HH:MM:SS`) and, past the drift limit, writes `setCurrentTime&time=` — the **host's naive local wall time, no offset**, because what has to match the booth is the OSD burned into every snapshot, not the camera's notion of UTC (its tz/DST config is left alone, as on Hikvision). Verified on the bench with the real driver: a 2 h-off host time set (drift 7200 → synced), set back, then read as 1 s drift → no write. The device monitor picks it up unchanged (it gates on `isClockSyncable`, not on the driver id). A wrong DST setting on the camera therefore no longer matters for the evidence trail — only `RealUTC` in event bodies stays skewed (above). ### Login lockout — the device monitor must never poll with a wrong password `General.LockLoginEnable=true`, `LockLoginTimes=5`, `LoginFailLockTime=300`: five bad Digest logins lock `admin` out for 5 minutes. A wizard assignment with a mistyped password, polled every few seconds by the device monitor, locks the camera and then **every** login (including the browser) fails until the poll stops. Verify the password with one `curl` before assigning; on a mysterious "401 then nothing works" wait five minutes. ## Bench notes - `10.0.10.11` is the runbook's address for the lab [[k200l-printer]] ([[site-device-installation]] §address plan) — the camera has taken it on the bench; keep the two off the wire together or move one. - The other HTTP APIs newer Dahua firmware carries (`RPC2` JSON, `/onvif/device_service`) were not exercised — the CGI above covers everything the app needs. - `devVideoInput.cgi?action=getCaps` and `magicBox.cgi?action=getProductDefinition` answer "Bad Request" / "Not Implemented" on this firmware. Related: [[lpr-camera]] · [[opencv-anpr-service]] · [[lane-presence-and-anpr-entry]] · [[clock-integrity]] · [[site-device-installation]] · [[device-registry]]