2915d141aa
Model the entry button (I1) and a Hikvision radar (I2) as named children of the access controller, and drive the button's 12V lamp on a spare relay. - Radar = the existing relays[].presenceInput one-car-one-ticket gate, now labelled presenceKind: loop|radar. A radar may idle opposite the button, so add a per-input active-level override: relays[].presenceActiveLow -> driver inputActiveLow set, inverting just that terminal (pure helper inputActive()). The Dingtian has one board-wide resting level otherwise. - AuxOutputDevice.setAux(channel,on) capability on the device interface (Dingtian latch) so business logic drives a NON-barrier lamp through the interface. Barriers still only pulseOpen — barrier-not-a-door preserved. - ButtonLightController: subscribes to the radar input edge + the camera lane status and drives a 3-state lamp — radar+car=solid, radar-only=blink (~1Hz), else off. Fails OFF on host loss/error; de-duped. A radar detection never opens a barrier on its own (advisory; threat model). - SetupWizard: presence kind + active-low + a button-light relay picker; sq+en i18n. Tests: button-light.test.ts (truth table + blink + fail-OFF + de-dupe), access-dingtian.test.ts (active-level inversion). Workspace build+lint+test green (158 server tests). Wiki: hikvision-radar, button-light-indicator + updates. Claude-Session: https://claude.ai/code/session_01Xcm6ikLgGoCxxHrxtjkk5V