Correction before schema work: the events table conflated the anti-fraud business ledger with device telemetry. Decision: ledger_events (signed, chained, reconciled) holds only business facts; device_events (unsigned, prunable) holds relay/printer/camera/reader/input telemetry. A raw button press is telemetry; the entry flow mints a signed vehicle_entry. Drops input_received-as-signed-event. New: decisions/event-streams-split, concepts/device-events; updated append-only-event-chain, index, log.
2.7 KiB
2.7 KiB
type, tags, sources, updated, status
| type | tags | sources | updated | status | |||||
|---|---|---|---|---|---|---|---|---|---|
| decision |
|
2026-06-15 | open |
Decision: Split the signed business ledger from device telemetry
Taken 2026-06-15, at the start of the business-layer schema work.
The problem
The existing events table (signed, hash-chained — append-only-event-chain) had grown to carry
two unrelated concerns: the financial/accountability ledger and raw device telemetry (button
pushes recorded as input_received). They have opposite requirements — the ledger must be small,
signed, and reconciled; telemetry is high-volume, churny, and disposable.
Decision — two tables
ledger_events— the signed, hash-chained, atecc608-signed business ledger (rename ofevents). Holds only business/accountability facts:vehicle_entry,vehicle_exit,payment,void,shift_z_report, and the witness-gradebarrier_open_command/barrier_open_observed/anomaly. reconciliation runs against this; sessions/tariff/occupancy are projections of it.device_events— unsigned operational telemetry (see device-events): relay fired, printer paper-out, camera offline, reader read, raw input edges. May rotate/prune. Never signed, never reconciled.
A raw button press is telemetry → device_events. The entry flow then mints a signed
vehicle_entry in the ledger once a ticket prints + the barrier is commanded. So
input_received-as-a-signed-event is dropped (it was transitional).
Why
- Keeps the signed ledger small and high-value — fewer rows to sign, hash, verify, reconcile, and export; signal isn't drowned in device noise.
- Right durability semantics per stream: the ledger is precious + append-only forever; telemetry can age out.
- Clean separation matches the device-adapter-pattern philosophy — device chatter stays on the device side of the boundary.
Consequences / migration (no production data yet)
- No
.sqlitewith real chain data exists, so renaming + restructuring is safe now (no signatures to invalidate). This is the moment to do it. - Code: rename
events→ledger_events;EventLog/canonicalize/verifyChainand the/api/eventsroutes follow the rename; add an unsigneddevice_eventswriter; move the Dingtian input-push handler to emitdevice_events(+ the entry flow signsvehicle_entry). ParkingEventTypeinpackages/sharedsplits into ledger types vs. a device-event type set.
Open
device_eventsretention/rotation policy.- Which device facts (if any) are witness-grade enough to also warrant a signed ledger entry
(e.g.
barrier_open_observedfrom a loop sensor) — see append-only-event-chain witness gap.