Two DT-008 units read disjoint card sets (park-buzi 125 kHz, lab unit 13.56 MHz only) although the box leaflet claims EM-ID + M1 + ISO 14443A/B + 15693 in one unit; recorded as unresolved with the EM4100 test that settles it (open question #18). Phone taps give a random 08… UID per tap, so phones are never RF credentials; 6H keeps the first three UID bytes reversed. Runbook §2 gains the tool's Setting-tab layout, a capability-identification checklist and the per-technology parameter table. reader-sink.py is a stdlib bench sink answering the push with the SDK verdict and Connection: close. Claude-Session: https://claude.ai/code/session_01FWncR69HgGPuei1dLrW3cU
18 KiB
type, tags, sources, updated, status
| type | tags | sources | updated | status | ||||||
|---|---|---|---|---|---|---|---|---|---|---|
| entity |
|
|
2026-09-17 | open |
Dingtian DT-008 (QR/RFID access reader)
The project's QR / barcode / RFID reader — Dingtian DT-008, the same vendor as the
dingtian-relay (which is why it integrates the same HTTP-push way). A static
optical + card scanner for QR / barcode (simple) and ID/IC/NFC cards. This is the
ticket-encoding scanner (read at the pay station / exit lane) and a path for QR
or RFID subscription credentials. Product page: dingtian-tech.com/en_us/qr_code_reader.html.
(See dingtian-dt008 / raw/.)
Naming correction (2026-06-28). Through most of this project this reader was wrongly called "GEE" / "GEE/Fondvision" / "GEE-QR-ER80" — a bad early assumption. There is no GEE device; it is the Dingtian DT-008. The driver id was renamed
gee-qr-reader→dingtian-qr-reader(migration 0015 rewrites existing rows). All protocol/behaviour facts below were observed on the real hardware and remain correct — only the device identity was wrong.
What it is
- QR/barcode + card. Reads QR / simple barcode AND ID/IC/NFC cards (~0.2 s, 0–10 cm). (An earlier note guessed "ER80-EM = 125 kHz EM4100 prox" — that was part of the same mis-id.)
- Interfaces: Wiegand 26/34, TCP/IP, USB, RS485 per the product page; the box leaflet (dingtian-dt008-box-manual) also lists RS232. (An earlier note dismissed RS-232 as a claim from the mis-identified GEE PDF — withdrawn 2026-09-17.) For our integration it talks HTTP over TCP/IP; Wiegand is the reader's output line on a valid read, not the host transport.
- Power 9–16 V DC, 800 mA; 86×86×42 mm; −30…70 °C. Fits the disk-os-hardening.
How it integrates — HTTP-GET push, server replies the verdict (confirmed via SDK)
The protocol is settled by the qrcode-sdk (not serial as first guessed).
The reader is configured (Windows tool QRCode_v1_6_5.exe) with a server IP/port and a "server
language" (only picks the URL path, e.g. /qa/mcardsea.php). On each scan it HTTP-GETs the host:
GET /qa/mcardsea.php?cardid=<QR>&mjihao=<devId>&cjihao=<devSN>&status=<2 chars>&time=<utc>
cardid = scanned data; status low digit = direction (1=in / 0=out). The host replies JSON
{data:[{cardid,cjihao,mjihao,status,time,output}],code:0} where reply status 1=valid (beep
2×) / 0=invalid (beep 1×), output 0=Access/1=WG26/2=WG34, time syncs the clock.
This is host-in-the-loop and SYNCHRONOUS: the GET is the access query and our reply is the
decision — it drives the reader's beep + output. So unlike a fire-and-forget reader, the endpoint
must decide (valid/invalid, direction from status) and reply, then also emit a DeviceReadEvent
on the read bus for the entry/exit/permit flows (parking-session, subscription) to open the
barrier. (device-input-flow is the analogous push pattern; this one also returns a verdict.)
This explains the "no beep": feedback comes from the server's JSON reply, not locally. A non-JSON / missing reply ⇒ no beep even though the scan worked. So "no beep" ≠ "didn't scan."
- Pushes over plain HTTP to our
10.0.10.xhost (on the device subnet); no serial wiring, no Wiegand-decode hardware. Suits the host-in-the-loop model; autonomy is moot anyway (dingtian-relay has no onboard ACL). - Default IP
192.168.1.99(set its server IP/port to this host in the vendor tool).
Resolved (2026-06-16)
- Protocol = HTTP GET poll + JSON verdict (above). The earlier "serial/Wiegand, find the baud"
open questions are moot — it's HTTP. Wiegand is the reader's output line on a valid read
(the reply
outputfield), not the host transport.
As-built (2026-06-16)
- Endpoint
GET/POST /qa/mcardsea.php(apps/server/src/routes/qr-reader.ts, public — the reader has no auth, sits on the device subnet). Parsescardid/mjihao/cjihao/status/time, runs the scan through the read dispatcher (permit match → permit flow; else transient exit), and replies the SDK verdict:status1=valid(beep 2×)/0=invalid(beep 1×),output0,time. - The read flows were refactored to return a
ReadOutcome{ accepted, direction, reason } so the endpoint's reply reflects the real accept/reject (the dispatcher decides AND opens the barrier via the flows). A fire-and-forget reader ignores the outcome. - Reader identity: the endpoint matches the device serial (
cjihao) against each reader'sconfig.serialto find itsdevicesrow; the dispatcher then resolves the relay that row is bound to (config.controllerId+relay) and opens it. See entry-exit-points. - Verified via inject: valid permit QR →
status:1+ open; re-scan → permit exit (still valid); unknown QR →status:0; reader on a barrier-less lane →status:0.
Verified on hardware (2026-06-16)
Captured a real scan (vendor-emulator logger on :3000). The reader does scan, send, and beep — the earlier "no beep" was simply that no server was answering on :3000 with valid JSON. Real GET:
GET /qa/mcardsea.jsp?cardid=52020056&mjihao=1&cjihao=H05M2AFA&status=11&time=1781634494
from 10.0.10.7 (referer: http://www.fondvision.com — the OEM is Fondvision)
- PATH carries the configured "server language" EXTENSION: this unit is set to JSP, so it
GETs
/qa/mcardsea.jsp— NOT.php. Our endpoint was registered at.phponly → it would have 404'd the real reader. Fixed: the route now registersphp/jsp/asp/aspx/cgi. cjihao=H05M2AFAis the device serial — the value our endpoint matches against the reader'sconfig.serial. So assign the reader withconfig.serial = "H05M2AFA"and bind it to a controller relay.mjihao= 1 (device id).cardid= the scanned barcode (52020056).status=11.- The reader beeped on the vendor reply with
status:0— so it acts on the reply;0= invalid/1-beep as documented. A matching permit/session will returnstatus:1→ 2-beep accept.
Assignment (as-built 2026-06-16)
A dedicated dingtian-qr-reader driver (device-registry, reader category) models the push reader:
its one config field is serial (the cjihao the device reports). The admin assigns it in the
first-run-setup like any device (normal UUID row id), enters the serial, and binds
it to a controller relay. The QR endpoint resolves the reader by matching config.serial to the
scan's cjihao — not by row id — so no DB hand-editing. Set the reader's server IP/port to this
host in the vendor tool; assign + enter its serial + bind it here.
- Verified via inject: assign
dingtian-qr-reader{serial:"H05M2AFA"} bound to an access relay → a.jspscan with that serial + a matching permit QR →status:1(2-beep accept) + open; re-scan → permit exit; unknown card →status:0; unassigned serial →status:0(no relay, graceful). - Note
tcpip-readeris the WRONG model for this device (host-connects-out, a stub) — usedingtian-qr-reader.
Open / next
- Re-test on hardware against the real app (now
.jsp-aware + serial-resolved): scan → expect astatus:12-beep when the QR matches a permit/open session. outputis replied as0(Access). Confirm on hardware whether the reader needs1/2(WG26/34) to drive its access line, vs.0.
Channel tagging — output prefixes close the printed-card-clone hole (2026-07-04)
The push carries ONE opaque cardid whether the optical engine decoded a QR/barcode or the
RF engine read a card — the server couldn't tell. And SubscriptionFlow.match matched by
value only (the stored rf/qr kind was a label). Consequence: printing a card's UID (often
written on the card face, e.g. 86A158) as a barcode and holding it up cloned the RF card —
the optical decode matched the RF credential and opened the barrier. In-threat-model and cheap.
Fix (both sides):
- Reader (vendor tool, both units): set
QRCode Output Prefix=Q:andCard Output Prefix=K:(env-overridable server-side:READER_QR_PREFIX/READER_CARD_PREFIX). - Server:
routes/qr-reader.tsstrips the prefix and tags the read's confirmed channel (DeviceReadEvent.channel: "optical"|"rf"; kindqr/card). Enrollment capture stores the bare value.SubscriptionFlow.matchthen requires channel agreement: an optical read may not claim anrfcredential (and vice versa) — a mismatch is refused AND signs asub.refused.channelMismatchanomaly (a clone attempt is a fraud signal). An unprefixed read keeps the legacy untagged shape and matches as before — enforcement only bites where prefixes are deployed, so an unconfigured reader never breaks. - Bonus: every
READlog line now carriesch=optical|rf, which permanently attributes any future phantom (see below) to its engine.
⚠️ Two device-side settings are now part of the credential contract (they live ON the reader,
not in our DB — re-apply after any factory reset/swap): the two output prefixes (must match
the server's expected Q:/K:), and Card Input format (currently 6H) — it defines the
UID shape we enroll; changing it later silently orphans every enrolled card.
⚠️ Phantom optical decodes from sunlight patterns (park-buzi, 2026-07-04)
With the site EMPTY (pre-opening, verified live + by snapshot), the exit reader
(cjihao=H05MA5B0) pushed spontaneous scans at random afternoon times (observed 16:38–18:14,
low-western-sun hours): cardid values like 997492, 389861, 024358, 192793 — and once a
lone C. Server logs (READ serial= lines) confirm the pushes carry the reader's own serial
and resolve to its assigned row, so this is the physical reader decoding, not a network source.
Diagnosis: the scan engine ships with many 1D symbologies enabled, some with weak/no checksums.
Six-digit all-numeric strings are the signature of Interleaved 2-of-5 (even-length, digits-only,
no checksum — any high-contrast stripe pattern of the right proportions "decodes"); a lone C is a
Code39/Codabar artifact (Codabar start/stop chars are A–D). Low sun creates exactly such
patterns at a gate: the striped barrier arm, fence/railing shadows sweeping as the sun moves, glare
bands. RFID noise would instead give repeating UID-shaped values.
Impact: noise, not risk. Every phantom was REFUSED fail-closed; a phantom can never match a ticket (ticket-encoding ids are 11-digit + Luhn, so a 6-digit read has nothing to match).
Feed filter (2026-07-04 — supersedes the earlier "do not filter" position). Initially each
phantom signed an exit.refused.noSession anomaly (#52–58 in the feed) and the position was to
keep it that way. The operator overruled it, correctly: red "who is trying to exit?" rows for
NOBODY train the operator to ignore the signed feed — alarm fatigue is the adversary's friend.
read-dispatch.ts now drops a no-match value that cannot possibly be a credential we issue to
UNSIGNED telemetry (device_events, unrecognizedRead:true — still auditable). "Possibly ours"
is deliberately WIDE and everything in it still signs the normal refusal anomaly: Luhn-valid
ticket shapes (a forged ticket is a real probe), SUB-/SUBSESS- prefixes, ANY read on a
confirmed-RF channel (a physical card is a real event, never sun noise), and plates (never
shape-filtered). The filter also works pre-prefix (legacy untagged reads). Still fix at the
source too:
Fix (vendor tool, per reader — config lives ON THE DEVICE, not in our DB): disable every symbology except QR + Code128 (all our credentials); if offered, set minimum decode length ≥ 10 and require checksums. Apply to BOTH readers. ⚠️ A factory reset or a swapped unit silently re-enables the phantom symbologies — re-apply after any reset/replacement. Physical fallback if any noise survives: hood/visor the window, tilt it down, avoid facing the striped arm.
⚠️ Two units, two card sets, no overlap — 125 kHz vs 13.56 MHz (2026-09-17, unresolved)
The product page says the DT-008 reads "ID/IC/NFC cards" and the box leaflet (dingtian-dt008-box-manual) claims EM-ID, M1, ISO 14443A/B and ISO 15693 in one unit. Yet on the bench 2026-09-17, with two card sets, the two units we own read disjoint sets:
| Unit | Serial family | Reads | Does not read |
|---|---|---|---|
| park-buzi entry/exit (bought 2026-06) | H05M… (H05M2AFA, H05MA5B0) |
the site's enrolled cards (125 kHz "ID", EM4100-class) | 13.56 MHz cards |
| lab unit (fresh, 2026-09) | HC002721 |
13.56 MHz "IC/NFC" cards (e.g. UID A238BC) |
the park-buzi card set |
The decisive test needs no hardware: hold each card on an NFC-capable phone. A 13.56 MHz card is detected; a 125 kHz card is invisible to a phone. The lab reader and the phone agreed on exactly the same set, and the other set was invisible to both — so the park-buzi set is 125 kHz and the park-buzi readers are the 125 kHz variant. Card bodies help too: EM4100 / TK4100 / T5577 (often a printed 10-digit decimal) = 125 kHz; Mifare / S50 / 1K / NTAG = 13.56 MHz.
Nothing in QRCode_v1_6_5.exe selects the frequency (no card-type field — see the screenshot in
site-device-installation §2).
Why the lab unit does not read them is NOT settled — the phone test only proves the park-buzi cards are not 13.56 MHz. Three explanations remain, with different fixes:
- The park-buzi cards are 125 kHz but not EM4100 (HID Prox / Indala / AWID / a T5577 in a non-EM format): invisible to a phone, not decoded by an EM-only front end, but read by the older batch. Card bodies help: EM cards usually print a 10-digit decimal; HID cards carry the HID logo.
- The lab unit's 125 kHz front end is dead or disabled — the leaflet says it should be there; a firmware setting the v1.6.5 tool does not expose is possible.
- The leaflet is generic and units ship per variant — the vendor can say from the two serials.
Decisive test (cheap): a known EM4100 125 kHz card/keyfob on the lab unit, held at 1–10 cm. Reads → its 125 kHz radio works and the park-buzi cards are a different 125 kHz format (→ 1). Does not read → unit defect or variant (→ 2/3, vendor with the serial). A USB keyboard-wedge EM4100 reader (~10 €) additionally says outright whether the park-buzi cards are EM4100.
Consequences (hold regardless of which explanation wins)
- A site's card stock and its readers must be proven together. A card enrolled at park-buzi
is not readable by the lab unit today, whatever the reason; a replacement reader must be tested
against the site's actual cards before it ships, or every enrolled card is orphaned — same
class of trap as the
Card Input format. - Purchase spec must name the card technology and format the site uses (the serial family is
only a hint:
H05M…reads park-buzi's cards,HC…does not). Ask the vendor (support address in the tool's title bar) which card types a given serial decodes. - Bench testing park-buzi card problems on the lab unit is meaningless until the lab unit is shown to read the site's card type.
- Open: with a 13.56 MHz unit the native UID is 4 or 7 bytes, so
Card Input format = 6Htruncates it — check on the lab unit which bytes survive and whether two cards can collide on the 6-hex value before enrolling anything against a 13.56 MHz reader (open-questions).
Record the variant on the site record next to the serial (site-device-installation §"Record").
A phone is not a card (2026-09-17). Tapping a phone on the 13.56 MHz unit beeps and logs a
different id every time (18CA08, 37F108, D5A908 three seconds apart). Read backwards
those are 08 CA 18, 08 F1 37, 08 A9 D5: a first UID byte of 08 is the ISO 14443
marker for a random UID, which every phone in card-emulation mode generates per tap so that
readers cannot track the handset. So a phone can never be enrolled as an RF credential, and a
phone tap in the logs is not a clone attempt — just noise with a fresh id each time. Same for
cards with a "random ID" feature (DESFire / Mifare Plus in random-UID mode): if a card ever
enrolls but "stops matching", check whether its id changes between taps.
Incidentally this shows what 6H does on a 13.56 MHz unit: the tool prints the first three
bytes of the 4-byte UID, byte order reversed, fourth byte dropped. Confirm against a card with
its UID printed on the body before enrolling; the dropped byte is the collision risk in
open-questions #18.
Bench sink — scripts/reader-sink.py (2026-09-17)
A stdlib-only Python HTTP server that answers the push on any /qa/mcardsea.* path with the SDK
verdict (--accept → status 1 / two beeps, default status 0 / one beep), Connection: close, and
prints one line per read: time, source IP, serial, dev, dir (from the status low digit),
ch (from the Q:/K: prefix), cardid, path. Point the reader's Server address / Server Port
at the laptop (python3 scripts/reader-sink.py -p 3000 --accept, port 80 needs admin rights). Use it
to see the raw cardid a card yields, to prove a reader pushes at all, and to time the beep against
the reply. No app, no DB, no Docker.
⚠️ Reply MUST set Connection: close (verified on hardware)
The reader sends Connection: keep-alive but only acts on the verdict (beep/output) once the TCP
socket CLOSES. Fastify's default keeps the connection alive → the reader waits out a ~10 s
keep-alive timeout before beeping, even though the server replied in ~15 ms. Every vendor demo
replies Connection: close and shuts the socket. Fix: the endpoint sets
reply.header("connection","close"). Symptom if regressed: correct accept/reject but a ~10 s lag
before the beep. (The request arrives fast; the delay is entirely the reader waiting for close.)