Files
parking_solution/apps
julian 6ceaadfbf2
Build desktop / desktop (push) Successful in 4m18s
CI / check (push) Successful in 44s
Build & push images / images (push) Successful in 2m51s
feat(devices): camera clock sync via ISAPI — heal the 1970 power-cut reset
park-buzi field observation: after a power cut the Hikvision cameras
reboot at the 1970 epoch (no/dead RTC battery, no NTP) and stay there
until a human logs into the web UI (which silently pushes the browser
clock) — corrupting the snapshot OSD timestamps (the evidence trail) and
ANPR push times meanwhile.

The host is the site's time authority (offline-first, no NTP infra):

- Device monitor triggers a sync at each camera's offline→ready edge —
  exactly the power-restored moment — plus a 24h backstop; the attempt
  is stamped before the async call so a failing camera retries at
  backstop cadence, never every poll.
- HikvisionCamera.syncClock: GET /ISAPI/System/time; drift ≤60s → leave
  alone; beyond (or unparseable = infinite drift) → PUT timeMode=manual
  with the site wall-clock now WITH explicit utc offset
  (localIsoWithOffset), echoing the camera's timeZone verbatim — correct
  the clock, never fight its tz/DST config.
- Jumps >1h (the power-cut signature) log warn (persisted to app_logs);
  small corrections info. Capability-guarded (isClockSyncable) —
  hikvision only; dahua's CGI has no such endpoint.
- http-digest generalised to digestRequest (GET/PUT/POST + body); the
  handshake was already method-aware. digestGet delegates unchanged.

8 new tests: in-sync no-op, 1970 PUT shape (manual + host instant +
echoed tz), unparseable→sync, failed-set surfaces, dahua non-capability,
DST-both-sides pins on the offset formatter.

Claude-Session: https://claude.ai/code/session_01Xcm6ikLgGoCxxHrxtjkk5V
2026-07-07 12:56:51 +02:00
..