Files
parking_solution/firmware/relay-proxy
julian c08e232339 feat(firmware): relay-proxy PoC — NodeMCU as a Dingtian DT-R004 + cloud proxy/watchdog
A NodeMCU v3 (ESP8266) that speaks the Dingtian wire contract (binary UDP 60000 with
relay_pw, string UDP 60001, config CGI incl. the setconfig gotcha, userset.cgi, Digest
input push) so the booth's existing driver needs no change, plus a heartbeat/command/
watchdog path to an ephemeral cloud stand-in (poc/cloud-standin.mjs). Verified at park-lab:
the booth's assign flow configured it like real hardware and a button press reached the
booth (401→Digest→200) and the cloud with the booth's status. Watchdog probes /health and
power-cycles the PC via a spare relay with backoff. IO behind one interface for the ESP32/
Dingtian port.

wiki: relay-proxy-firmware page; esp32-flashability-test runbook (esptool lock test);
dingtian-relay "can we flash our own firmware" (vendor locks the standard SKU);
site-device-installation: booth ufw must allow device-net → 3000 (push targets PORT, not
Caddy's 80); open-questions: cloud takeover vs signed ledger (parked).

.gitignore: firmware venv/.pio/secrets.h.
2026-10-22 12:08:20 +02:00
..

relay-proxy — Dingtian emulator + cloud proxy/watchdog (PoC)

A NodeMCU v3 (ESP8266) that is a Dingtian DT-R004 to the booth server and, on top, a proxy and watchdog toward a cloud service. The booth's existing dingtian driver talks to it unchanged. It is the seed of the custom firmware for the real Dingtian board (ESP32); the IO layer is the only board-specific file.

Why: park-2's booth PC died twice unnoticed. The device that already owns the barrier relay and the button inputs becomes the resilient core: it reports to the cloud independently of the PC, can power-cycle the PC, and keeps accepting commands from the cloud when the PC is dead. See wiki/entities/dingtian-relay.md and wiki/decisions/cloud-service-saas.md.

What it emulates (the booth sees a DT-R004)

Surface Behaviour
UDP 60000 binary FF AA s cmd pwLo pwHi …: 00 status, 01 write (mask,set), 03 jog. Reply FF AA s cmd relayByte inputByte. Wrong relay_pw → dropped silently.
UDP 60001 string 00, 1N, 2N, 1N*. Password-less. Enabled at factory; harden() turns it off (udp2.p=255).
GET /api/v2/config.cgi The config JSON (relay_connect, input_link_relay, input_link_url).
POST /api/v2/config_set.cgi Applies + persists (LittleFS). Requires "command":"setconfig" like the real device.
GET /userset.cgi?u&old&u&new& Web-login rotation, &0& ok / &2& wrong old password.
Input push On input change, Digest-authenticated GET to the booth's on_path/off_path.
input_link_relay Factory ON (input auto-fires its relay) until the booth's precondition fix clears it.

Extra, PoC-only: GET / status text, POST /poc/factory_reset.

Proxy / watchdog (toward CLOUD_URL)

  • Heartbeat every 10 s: IP, booth health, relay/input state, config flags.
  • Every input change is mirrored to the cloud (/event) with the booth push result.
  • Command poll every 2 s: {"pulse":ch,"ms":500}, {"watchdog":false}, {"reboot_pc":true}.
  • Watchdog: probes BOOTH_HEALTH_URL every 5 s; after 6 failures in a row it pulses relay 2 for 3 s (meant for an NC contact in series with the PC's mains, with BIOS AC Recovery = On), then backs off 10 min. The cloud can disable it.

Pins (NodeMCU v3) — no wiring needed to start

Function Pin
Relay 1 (barrier) D1 / GPIO5, mirrored on the on-board LED
Relay 2 (PC power) D2 / GPIO4
Relay 3, 4 D5 / GPIO14, D6 / GPIO12
Input 1 (button) the on-board FLASH button (GPIO0), active LOW
Input 2 D7 / GPIO13, short to GND

Build / flash

cd firmware/relay-proxy
copy include\secrets.h.example include\secrets.h   # fill in; gitignored
..\.venv\Scripts\pio run -t upload
..\.venv\Scripts\pio device monitor

Cloud stand-in (throwaway): node poc/cloud-standin.mjs on a host the device can reach.

Register it in the booth

Devices → add Dingtian relay controller: host = the NodeMCU's IP (give it a DHCP reservation or set STATIC_IP; the booth only accepts pushes from the registered IP), channels 4, binary port 60000, string port 60001, HTTP port 80. On save the booth runs the normal flow: precondition fix (clears input_link_relay), harden() (random relay_pw, disables udp2, rotates the web login), and configureInputPush() (Digest creds + URLs). The serial log shows each step land.

Limits of the PoC

  • Wi-Fi only; the real target has Ethernet.
  • HTTP calls block the loop briefly (~100 ms); fine for a demo, not for production.
  • The config JSON mirrors the keys the booth driver uses, not the full device schema.
  • Plain HTTP to the cloud stand-in; the real cloud link needs TLS.