julian 7b29331f52 fix(devices): Hikvision clock sync owns the time zone (fixed offset, re-set at DST edges)
park-2's cameras burned Beijing time into every frame: factory zone CST-8,
and the sync compared instants only, so zero drift meant the zone was never
touched. The G3H firmware also accepts a POSIX zone with a DST rule, echoes
it back, and ignores the rule.

syncClock now derives the site's current UTC offset as a fixed Hikvision
zone (hikvisionFixedZone) and rewrites it when it differs, sending the clock
with it. The device monitor adds a third trigger beside offline->ready and
the 24h backstop: the moment the site's UTC offset changes, so a DST switch
is handled within one poll. ClockSyncResult reports zoneChanged/timeZone.

Both park-2 cameras were set to CST-2:00:00 by hand on 2026-10-09; this
must be deployed there before 2026-10-25 or the OSD reads 1h ahead from
that day until it is.
2026-10-11 18:17:25 +02:00
..