Files
parking_solution/wiki/raw/dingtian_qr_linux/PROTOCOL.md
T
julian b7efa081ec
Build & push images / images (push) Successful in 3m7s
feat(devices): DT-008 reader discovery + auto-configuration over the vendor UDP protocol
The Dingtian DT-008's Windows-only config tool speaks a small binary UDP protocol
(reader :24680 unicast get/set, :24582 broadcast search/set-network), reversed in
wiki/raw/dingtian_qr_linux (PROTOCOL.md + dingtian_qr.py, copied to scripts/). Reading
park-2's readers with it from the booth found both in WG26 output mode — the "beeps but
captures nothing" enrolment failure: they never pushed HTTP at all.

The app now speaks the protocol itself (packages/devices dingtian-qr-config.ts, Node dgram,
host-network container) and the dingtian-qr-reader driver uses it:
- discover(): first driver to implement the wizard's Scan capability; rows show serial, IP,
  output mode, current server target, card format, firmware.
- preconditions: output type must be HTTP (fixable — save switches it); typed serial must
  equal the reported one and the reader must answer on UDP (both block the save).
- configureInputPush(): set-network the reader's server to this booth's IP + listen port,
  confirmed by polling (the reader applies it without an ack and is silent for seconds).
- usesPushAuth=false: the scan GET carries no credentials, so no push secret is stored.
- a reader saved without an IP warns instead of failing (legacy vendor-tool setup).

Verified on the bench unit: WG26→HTTP, target 8080→8081→8080, struct byte-identical after.
15 protocol tests against a fake reader + 17 adapter tests. Wiki: device-discovery,
first-run-setup, dingtian-dt008-reader, site-device-installation §2 (SSH procedure; the
"needs a Windows laptop" claim withdrawn), new source page dingtian-qr-linux-tool.
2026-10-08 15:22:33 +02:00

15 KiB
Raw Blame History

Dingtian QR code / RFID reader – configuration protocol

Reverse engineered from QRCode_v1_6_5.exe (Dingtian-Tech QRCode V1.6.5, statically linked Qt 5 Win32 application) by static analysis of the binary plus packet captures against a real reader (serial HC002721, model doorqrcode, firmware ver_client1_1.1, chip v3s, hardware h42) and a fake reader used to exercise the Set buttons.

dingtian_qr.py in this folder is a working, dependency-free Python 3 implementation (discover / info / get / set / set-network) that runs on Linux.

1. What the exe does

The exe has two tabs.

  • Setting – the configuration tool. It talks to readers over UDP:
    • Search device broadcasts command 2 to <interface broadcast>:24582 on every local IPv4 interface. Readers answer with command 3 (96 byte DeviceInfo block). Discovered readers are kept in an in-memory list (one 768 byte record per reader) and shown by serial number.
    • Get parameter sends commands 0 and 30 unicast to <reader ip>:24680 and fills the form from the 64 byte firmware block and the 720 byte parameter struct.
    • The three Set buttons send a fixed sequence of small commands (below). Each write is acknowledged by the reader with cmd+1 and a 1 byte status (0 = OK); the exe prints "... success!" when the acknowledgement arrives.
    • The form shows the stored record of the selected reader. A new record is filled with built-in defaults until a Get parameter reply has been received, which is the behaviour you see as "the UI does not show the selected device params". Reading the parameters directly (command 30) every time avoids this.
  • Test device – a tiny HTTP (or raw TCP / UDP) server on a configurable port (default 80) that receives the scan pushes the reader makes in HTTP output mode and answers with the JSON documented in the SDK (qrcode_HTTP_GET.txt). The "TCP" and "UDP" listener types of that tab were not analysed. The HTTP push is: GET /qa/mcardsea.php?cardid=<data>&mjihao=<device id>&cjihao=<serial>&status=<2 digits>&time=<unix> and the reply is {"data":[{"cardid":"...","cjihao":"...","mjihao":"...","status":1,"time":<unix>,"output":0}],"code":0,"message":"success"} (status 1 = valid, beep twice; 0 = invalid, beep once; time syncs the reader clock; output 0 access, 1 WG26, 2 WG34). This part is independent of the UDP protocol.

The reader's default IP is 192.168.1.99 (see readme.txt). A reset hole on the back restores factory settings.

2. Frame format (UDP, both directions)

offset size  field      notes
 0      4    'XXXX'     magic (0x58 0x58 0x58 0x58)
 4      4    id         little-endian u32; PC sends 0, reader echoes an arbitrary value
 8      4    cmd        little-endian u32; even = request/write, odd = reply (cmd + 1)
12      4    len        little-endian u32; payload length in bytes
16      1    checksum   (0xFF - sum(payload bytes)) & 0xFF   -> 0xFF when len == 0
17      len  payload

All integers are little-endian. The exe sends the header and the payload as two separate datagrams (17 byte header, then the raw payload). Reader replies arrive as a single datagram (header + payload). The Python tool mimics the two-datagram write.

Ports: reader listens on 24680/udp (unicast) and 24582/udp (broadcast, used for search and set-network). Replies are sent to the IP:port the request came from, but the reader's source port is not fixed: unicast replies came from 24680, search replies came from an ephemeral port (52512 in the capture). A host firewall therefore has to allow inbound UDP to the tool's socket (or track UDP "related" traffic); filtering on the reader's source port does not work.

Broadcast address: the exe computes ip | ~netmask for every local IPv4 interface and sends the search to each one (it does not use 255.255.255.255). Readers and PC must be on the same layer 2 segment for search and set-network; get/set commands are plain unicast and are routable. The exe also binds its own socket to 24582 so it can receive readers that announce themselves; two copies of the exe on one PC therefore fight over that port.

Worked examples

Search request, no payload (checksum of nothing = 0xFF):

58 58 58 58  00 00 00 00  02 00 00 00  00 00 00 00  ff
magic        id = 0       cmd = 2      len = 0      checksum

Set buzzer on (command 18, payload = u32 1): payload bytes sum to 1, checksum = 0xFF - 1 = 0xFE. Sent as two datagrams:

datagram 1: 58 58 58 58  00 00 00 00  12 00 00 00  04 00 00 00  fe
datagram 2: 01 00 00 00

Reader acknowledgement (cmd 19 = 18 + 1, one status byte 0x00, checksum 0xFF - 0 = 0xFF):

58 58 58 58  00 00 00 00  13 00 00 00  01 00 00 00  ff  00

Only status 0 has been observed; treat anything else as an error.

Set card prefix "AB" with ASCII type (command 44, 72 byte payload):

01 00 00 00            card output format = 1 (ASCII)
01 00 00 00            card prefix/suffix type = 1 (ASCII)
41 42 00 .. 00         prefix "AB", 32 bytes NUL padded
00 00 .. 00            suffix empty, 32 bytes

Python reference: checksum = (0xFF - sum(payload)) & 0xFF; header = b'XXXX' + struct.pack('<III', 0, cmd, len(payload)) + bytes([checksum]).

3. Commands

cmd dir payload meaning
2 PC → bcast :24582 none search; every reader replies with 3
3 reader → PC 96 B DeviceInfo search reply
0 PC → reader none firmware info; reply 1
1 reader → PC 64 B FirmwareInfo
30 PC → reader none get parameters; reply 31
31 reader → PC 720 B Params
32 PC → bcast :24582 96 B DeviceInfo set network parameters. Reader matches the serial in the block. Reply 33
6 PC → reader u32 output type (1..10, table below)
8 PC → reader u32 card input format (1..5)
10 PC → reader u32 byte0 = "last add Enter" (0/1), byte1 = "last add new line" (0/1)
38 PC → reader 5 × u32 baud, data bits (5..8), stop bits (1/2), parity (0..4), QR output format (0..4)
12 PC → reader u32 + 32 B QR prefix/suffix type (0 HEX, 1 ASCII) + QR prefix (raw bytes, NUL padded)
14 PC → reader u32 + 32 B same type value + QR suffix
44 PC → reader u32, u32, 32 B, 32 B card output format (0 HEX, 1 ASCII), card prefix/suffix type (0 HEX, 1 ASCII), card prefix, card suffix
28 PC → reader 2 × u32 Wiegand high pulse / 100, low pulse / 100 (microseconds; UI shows 2000 / 400)
40 PC → reader u32 scan code fill light: 0 close, 1 open (Params 0x218)
18 PC → reader u32 work mode: 0 normal, 1 single, 2 interval (Params 0x1f0)
16 PC → reader u32 restart interval: 0 no, 1 every 12 h, 2 every 24 h (Params 0x1ec; the test reader rejected 2)
22 PC → reader u32 buzzer: 0 off, 1 on (Params 0x1f8)

Every write is answered with cmd+1, len = 1, payload = 1 status byte: 00 = value applied (the parameter struct changes immediately, no commit or reboot needed), 01 = value rejected (out of range), struct unchanged. A write whose header and payload are sent in one datagram gets no answer and is ignored.

The 18/22 and 40/16 assignments were confirmed on the real reader by sending each command alone and diffing the 720 byte struct afterwards (the exe's two Set passes alone could not tell them apart because both fields of each pair changed together).

Button → command sequence in the exe:

  • Network Set: 32 (broadcast).
  • Format Set: 6, 8, 10, 38, 12, 14, 44, 28 (in this order, back to back).
  • External Set: 40, 18, 16, 22.

The exe's receive dispatcher accepts reply commands 1..41; other odd commands exist in the jump table but are not used by the UI.

Enumerations (values as sent on the wire)

field values
output type (cmd 6, Params 0x198) 1 USB virtual keyboard, 2 USB virtual serial port, 3 HTTP, 4 MQTT, 5 RS232, 6 WG26, 7 WG34, 8 RS485, 9 AC Output, 10 TCP
card input format (cmd 8, Params 0x19c) 1 6H, 2 8H, 3 8H10D, 4 6H10D, 5 2H3D+4H5D
QR output format (cmd 38[4], Params 0x214) 0 Decimal, 1 HEX, 2 Decimal Reverse, 3 HEX Reverse, 4 ASCII
prefix/suffix type, card output format 0 HEX, 1 ASCII (HEX only changes how the exe displays/enters the bytes; the wire always carries raw bytes)
parity (cmd 38[3], Params 0x210) 0 Even, 1 Odd, 2 None, 3 Space, 4 Mark
baud (cmd 38[0]) actual value; exe list: 110 134 150 300 600 1200 1800 2400 4800 7200 9600 14400 19200 38400 57600 115200 128000 256000
restart interval 0 No, 1 12Hours, 2 24Hours
work mode 0 Normal, 1 Single, 2 Interval
buzzer 0 Off, 1 On
fill light 0 Close, 1 Open
DHCP (Params 0x000) 0 Static IP, 1 DHCP
HTTP server language (Params 0x04c, DeviceInfo 92) 0 PHP, 1 JSP, 2 C#, 3 ASP, 4 CGI

4. Data blocks

IPv4 addresses are stored as a little-endian u32, i.e. the bytes of inet_aton() reversed: 10.0.10.12 is 0c 0a 00 0a.

DeviceInfo – 96 bytes (reply 3, payload of 32)

 0  20  serial number, NUL padded ASCII ("HC002721")
20   4  ip
24   4  netmask
28   4  gateway
32   4  dns1
36   4  dns2
40  48  server address, NUL padded string (hostname or IP, e.g. "10.0.10.204";
        factory default is "ipc.fondvision.com")
88   4  server port (u32, e.g. 8080)
92   4  HTTP server language (0 PHP .. 4 CGI)

Note: the exe's set-network code builds this block by writing the 20 byte serial over the first 20 bytes of its 80 byte network record (dhcp, ip, ..., language). The DHCP word is therefore overwritten by the serial and DHCP is never transmitted by the exe; the DHCP combobox has no effect on the wire.

FirmwareInfo – 64 bytes (reply 1)

 0  16  model        "doorqrcode"
16  16  firmware     "ver_client1_1.1"
32   8  chip         "v3s"
40   8  hardware     "h42"
48  16  serial       "HC002721"

Params – 720 bytes (reply 31)

0x000  4  dhcp (0 static, 1 dhcp)
0x004  4  ip
0x008  4  netmask
0x00c  4  gateway
0x010  4  dns1
0x014  4  dns2
0x018 48  server address string
0x048  4  server port
0x04c  4  HTTP server language
0x050 .. 0x197  reserved / zero on the test reader (MQTT and other hidden settings
               probably live here; the exe never reads them)
0x198  1  output type                 (cmd 6)
0x19c  1  card input format           (cmd 8)
0x1a0  1  last add Enter              (cmd 10 byte 0)
0x1a1  1  last add new line           (cmd 10 byte 1)
0x1a4  4  QR prefix/suffix type       (cmd 12 word)
0x1a8 32  QR prefix                   (cmd 12 bytes)
0x1c8  4  QR prefix/suffix type again (cmd 14 word)
0x1cc 32  QR suffix                   (cmd 14 bytes)
0x1ec  4  restart interval            (cmd 16)
0x1f0  4  work mode                   (cmd 18)
0x1f4  4  unknown (0 on test reader, not shown by the exe)
0x1f8  4  buzzer                      (cmd 22)
0x1fc  4  high pulse / 100            (cmd 28[0])
0x200  4  low pulse / 100             (cmd 28[1])
0x204  4  baud rate                   (cmd 38[0])
0x208  4  data bits                   (cmd 38[1])
0x20c  4  stop bits                   (cmd 38[2])
0x210  4  parity                      (cmd 38[3])
0x214  4  QR output format            (cmd 38[4])
0x218  4  scan fill light             (cmd 40)
0x21c .. 0x287  zero on the test reader
0x288  4  card output format          (cmd 44[0])
0x28c  4  card prefix/suffix type     (cmd 44[1])
0x290 32  card prefix                 (cmd 44 bytes 8..39)
0x2b0 32  card suffix                 (cmd 44 bytes 40..71)

Reference capture from the test reader (HTTP mode, server 10.0.10.204:8080, PHP, card input 8H, add Enter on, 9600 8N1, ASCII formats, pulses 2000/400 µs, restart 12 h, normal mode, buzzer off, fill light open):

0000: 00000000 0c0a000a 00ffffff 010a000a 08080808 04040808 "10.0.10.204"...
0048: 901f0000 00000000 ...
0198: 03 00 00 00 02 00 00 00 01 00 00 00 01 00 00 00 ...
01c8: 01 00 00 00 ...
01ec: 01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01fc: 14 00 00 00 04 00 00 00 80 25 00 00 08 00 00 00 01 00 00 00 02 00 00 00 04 00 00 00 01 00 00 00
0288: 01 00 00 00 01 00 00 00 ...

5. Implementation notes for other tools

  • Build the header with the checksum of the payload, send header then payload (two datagrams), then wait for a datagram whose command equals cmd + 1. The exe does not retry; the Python tool retries twice with a 2 s timeout.
  • Discovery: send command 2 to the subnet broadcast, collect command 3 replies for about 2 s, de-duplicate by serial. The reply block already contains the IP to use for unicast commands.
  • Reading: command 30 is enough for the whole form; command 0 only adds firmware info.
  • Writing a single field: there is no "write the whole struct" command. Read the struct first, then send only the small command that owns the field (table in section 3). Commands 38, 12, 14 and 44 carry several fields at once, so fill the untouched ones from the struct you just read.
  • Changing IP/server: broadcast command 32 with the 96 byte block; the serial selects the reader. Expect the reader to answer 33 (not captured on the real unit because that would have changed its configuration).
  • Prefix/suffix fields are raw bytes (max 32). "HEX" vs "ASCII" type only tells the reader (and the exe's form) how to interpret them.
  • Pulse widths are stored in units of 100 µs (2000 µs on the wire is 20).

6. Verification status

  • Search, firmware info, get parameters and the acknowledgement format were captured from the real reader and reproduced with dingtian_qr.py.
  • The write payloads (commands 6, 8, 10, 12, 14, 16, 18, 22, 28, 32, 38, 40, 44) were captured from the exe while it talked to a fake reader, with two different sets of form values, and matched against the parameter struct and the disassembly.
  • Real writes verified on the HC002721 reader: commands 18, 22 and 40 each change exactly the struct word listed above and are acknowledged with status 0; out-of-range values (22 ← 2, 16 ← 2) are acknowledged with status 1 and change nothing; a single-datagram frame is ignored. The reader was restored to its original configuration afterwards (struct byte-identical to the first capture).
  • Not verified on a real reader: the Format commands (6, 8, 10, 12, 14, 28, 38, 44) and set-network (32); their byte layouts are identical to the exe's.
  • Not understood: Params 0x1f4, the reserved area 0x050..0x197 (likely MQTT settings), and what the reader does with a DHCP = 1 flag.

7. Linux quick start

python3 dingtian_qr.py discover --broadcast 192.168.1.255
python3 dingtian_qr.py info 192.168.1.99
python3 dingtian_qr.py get 192.168.1.99
python3 dingtian_qr.py set 192.168.1.99 --output-type 3 --buzzer 1 --fill-light 1
python3 dingtian_qr.py set-network --serial HC002721 --ip 192.168.1.50 --netmask 255.255.255.0 \
    --gateway 192.168.1.1 --dns1 8.8.8.8 --dns2 8.8.4.4 --server 192.168.1.10 --server-port 8080 \
    --http-language 0 --broadcast 192.168.1.255

set reads the current parameters first and only changes the fields you pass, then sends the full Format and External sequences exactly like the exe.