Files
processor/test
julian d758c211ae Fix metric wiring gaps audited against live processor output
Several Phase 1 metrics were registered in observability/metrics.ts but
either unwired at the call sites or wired with wrong counts. Production
output showed 11 records ingested per logs but only 4 in metrics. The
fixes below align metric values with actual hot-path activity.

Wiring gaps closed (consumer.ts):
- processor_consumer_reads_total{result=ok|empty|error} — was registered
  but never inc'd. Now fires on each XREADGROUP outcome.
- processor_consumer_records_total — was registered but never inc'd.
  Now fires once per XREADGROUP, with the entry count.

Counts corrected (writer.ts):
- processor_position_writes_total{status} — was inc'd unconditionally
  by 1 per chunk for each of inserted/duplicate. Now inc'd by the
  actual per-status count, and only when count > 0.
- processor_position_writes_total{status='failed'} — was inc'd by 1
  per failed chunk. Now inc'd by chunk.length so every failed record
  is counted.

Counts corrected (main.ts):
- processor_acks_total — was inc'd by 1 per non-empty batch. Now
  inc'd by ackIds.length so every ACK'd ID is counted.

Wiring gap closed (state.ts):
- processor_device_state_evictions_total — internal `evicted` counter
  existed but was never published to metrics. createDeviceStateStore
  now accepts a Metrics injection and inc's on each eviction.

Metrics interface extended (types.ts, metrics.ts):
- Metrics.inc gained an optional third `value` parameter (defaults to 1)
  for batched increments. dispatchInc passes it through to prom-client's
  Counter.inc(labels, value).

Tests updated to reflect the new third arg and the state.ts factory's
new metrics parameter. Total 134 unit tests passing (no count change —
existing tests adjusted, no new tests added; the real verification is
on stage where the metrics are now meaningful again).
2026-05-01 11:43:06 +02:00
..