julian 5fe313b7fa Link protocol v2 receiver, ESP-NOW leg, Patrol gauge outputs, gear pulse
- protocol header v2 copied byte-identical from the 5B repo
- uart_receiver: processFrame() shared by the UART framing task and ESP-NOW,
  version check, dedupe on packet_id+timestamp, per-transport liveness,
  CONFIG cache with sequence number
- espnow_receiver: STA mode, channel hopping while silent, locks on frames
- gauge_outputs: tach on IO7 (LEDC ch2, 14-bit), coolant PWM on IO8 (LEDC
  ch4, 8-bit), config cached in NVS, overrides applied but not saved
- main: gear label from lever + engaged/target (pulses while shifting, red on
  mismatch), icons driven by A's alert bits, gauge update at 5 Hz, link stats
- wiki: temp_stage.cfd (user's old CANNY program) decoded as prior art;
  controller-link, link-redundancy, patrol-gauge-outputs, open-questions
  updated with the bench-verified v2 results and calibration procedure

Co-Authored-By: Claude <noreply@anthropic.com>
2026-09-21 19:12:38 +02:00

10 KiB
Raw Blame History

type, tags, updated
type tags updated
concept
gauges
pwm
ledc
nissan-patrol
hardware
design
2026-09-21

Driving the Patrol Cluster Gauges

Goal (user, 2026-09-21): generate signals from Controller B to drive the Nissan Patrol instrument cluster's RPM (tachometer) and engine coolant temperature gauges, fed by the BMW data that arrives over the controller-link.

Why B and not A

Controller A (5B) has no free native GPIO on any header: the RGB LCD, I2C, CAN, RS485, USB and PSRAM consume every pin, and its two "DO" terminals are optocoupled outputs driven through a CH422G I2C expander — no hardware timer can reach them (sibling: 5B wiki → esp32-s3-touch-lcd-5b; schematic reviewed 2026-09-21). B exposes 13 free GPIOs on headers (esp32-s3-lcd-1-3), all usable by the ESP32-S3 LEDC peripheral.

Two very different signals

Gauge What the cluster expects What B must generate Status
Tachometer a pulse train whose frequency tracks engine speed — 4 pulses per revolution on this cluster (user, 2026-09-21; not yet bench-verified) variable-frequency square wave at ~50 % duty, on one LEDC channel with its own timer source data (RPM from CAN 0x0AA) verified on A (sibling: 5B wiki → can-id-candidates); not yet in the packet
Coolant temp a moving-coil/bimetal gauge that reads the resistance to ground of the sender fixed-frequency PWM with variable duty into a low-side switch, so the gauge integrates it as an average resistance coolant already in the packet as 0.1 °C

The two need separate LEDC timers because one varies frequency and the other varies duty. ESP32-S3 LEDC has 8 channels on 4 timers (unverified — datasheet figure from memory, confirm).

Pin assignment (implemented 2026-09-21)

  • IO7 → tachometer pulse output — LEDC channel 2 (timer 1), 14-bit resolution so the divider reaches low frequencies (~4.8 Hz .. ~4.9 kHz; 8-bit could not even do 100 Hz), 50 % duty
  • IO8 → coolant gauge PWM output — LEDC channel 4 (timer 2), 8-bit duty at temp_pwm_hz (default 1 kHz)
  • LEDC channels 0/1 (timer 0) belong to the display backlight; never reuse them (repo)

Bench-verified 2026-09-21 (verified): with A's default 89 °C coolant, B drives IO8 at duty 183/255 (1.5·89 + 50); cfg override rpm 2000 on A's console produced 133.3 Hz on IO7 (2000 × 4 / 60), and clearing it dropped the output. Both outputs stay low with no link or no valid value. Still unverified: the needle — nothing is connected to the cluster yet and the external driver stage does not exist.

Both on the right header, adjacent to GND-free pins, so add a ground wire from the left header. IO3 deliberately avoided (strapping pin). IO1 stays the UART RX.

Electrical interface — mandatory external stage (unverified)

3.3 V logic drives neither gauge directly.

  • Tach input: Patrol clusters expect roughly 12 V-level pulses (ignition-coil negative or ECU tach output, open-collector with the cluster's internal pull-up). Use an NPN or logic-level N-MOSFET as an open-collector pulling the tach wire to ground; if the cluster has no internal pull-up, add one to +12 V (a few kΩ). Never feed 12 V back into IO7.
  • Temp gauge: sender wire goes to ground through the sender's thermistor. Emulate it with a logic-level N-MOSFET (or NPN) pulling the sender wire to ground under PWM, plus a series resistor sized so 100 % duty corresponds to the hottest resistance you want to show. The gauge's thermal/mechanical lag averages the PWM; use a few hundred Hz to 1 kHz so nothing flickers. Calibration is a lookup table from °C → duty, built empirically against the needle.
  • Optocouplers between B and the 12 V cluster side are cheap insurance; the 5B's own DO stage (PC817 → transistor) is a reasonable pattern to copy.

Characterising the gauges (procedure, unverified until run)

The coolant gauge is a current meter, not a pulse input — there is no pulse count to find. The sender is a thermistor to ground; the needle follows the current through the gauge coil, which follows the sender's resistance. What has to be measured is the resistance → needle curve.

Coolant gauge, ignition on, engine off, sender disconnected:

  1. 1 kΩ linear pot (or decade box, or fixed 47/100/220/470 Ω) from the sender wire to chassis ground. Sweep; record the resistance at the cold mark, middle, hot mark and start of the red zone (read the pot disconnected).
  2. At each point also record the sender-wire voltage. Constant regardless of resistance → regulated supply, bimetal gauge. Proportional drop → plain series coil.
  3. Needle lag of seconds → bimetal; near-instant → air core. Both average PWM; bimetal is more forgiving.
  4. Series current at the hot-mark resistance = the peak the MOSFET stage must sink (expect tens of mA).

PWM drive from the curve:

  • Logic-level N-MOSFET low side, drain to the sender wire through a fixed resistor equal to the hottest resistance ever to be shown; 100 % duty = hottest reading, the gauge integrates lower duties.
  • 500 Hz – 2 kHz. Older Nissan clusters feed gauges from a chopped instrument voltage regulator at a few Hz (unverified); PWM near that rate beats against it. Scope the sender wire once to see whether the chopper exists.
  • Build the °C → duty lookup from where the needle actually lands at each duty step, not from any sender datasheet.

Tachometer, 4 ppr: f = rpm × 4 / 60 → ~47 Hz at 700 rpm, ~267 Hz at 4000 rpm. Before wiring: measure the tach input's open-circuit voltage with ignition on — battery voltage means the cluster has its own pull-up (open-collector output suffices); near zero means add a pull-up to 12 V. Verify the needle at two known LEDC frequencies before trusting the scaling.

Prior art: the user's CANNY 5.3 pico program (source: temp-stage-cfd)

The user drove this gauge before, from the BMW CAN bus, with a CannyLab program → temp-stage-cfd. Recovered from the file:

  • Same decode the 5B later verified: CAN 0x1D0 byte 0, raw − 48 °C.
  • Duty = 1.5 × T + 50 on a 0–255 scale, i.e. 110/255 at 40 °C, 200/255 at 100 °C, saturating near 137 °C. Duty rises with temperature (NTC sender emulation).
  • Output only enabled above a minimum temperature (constant 0 in the file, 40 °C in the comment).
  • Output was the controller's own push-pull pin with PWM pull-up enabled; the external circuit and the PWM frequency are not in the file.

Starting point for the LEDC implementation: 8-bit duty, duty = clamp(1.5·T + 50, 0, 255), output disabled while the coolant value is invalid or the link is down. Verify against the needle before trusting it — the old drive circuit may differ from the new MOSFET stage, which shifts the whole curve.

Tuning parameters — declared on A, executed on B (implemented 2026-09-21)

Calibration lives on Controller A (NVS; the Gauge Tuning touchscreen page — Home → right → Driveline → right — or the cfg serial console) and is pushed to B in CONFIG frames; B executes and caches the last config in its own NVS. link_config_t in the shared protocol header:

Group Parameter Default Note
Tach pulses per rev 4 user figure
Tach fine trim % 0 needle reads N % off at a known rpm
Tach min / max output Hz tbd clamp against bad rpm values
Temp PWM frequency Hz unknown from the CANNY measurement (temp-stage-cfd)
Temp duty slope, offset (fixed-point) 1.5, 50 from the CANNY law
Temp min temperature gate °C 40 output off below
Temp duty clamp 255
Both output enable on per gauge
Both calibration override off force a fixed rpm / fixed duty from A's screen and watch the needle

Transport: CONFIG frames in protocol v2, sent on start, on every change (cfg_version bump) and every 5 s; overrides are pushed but never saved on either side. Console: cfg show, cfg set <name> <value>, cfg override rpm <n> | duty <n> | both <rpm> <duty> | off, cfg reset → controller-link.

Measuring the CANNY's PWM without a scope: use a free 1.3 header GPIO with the ESP32 pulse-counter peripheral as a frequency/duty meter (resistor divider if the CANNY output exceeds 3.3 V). Same sketch later verifies B's own outputs. Planned as a separate PlatformIO environment in this repo.

Calibration procedure (touchscreen or console)

Tachometer, with the driver stage on the tach wire:

  1. Force 1000 rpm (override). The needle should read 1000.
  2. A constant-factor error means the wrong pulses/rev — change it until 1000 reads 1000.
  3. Force 3000 rpm; a small residual is the trim (%).
  4. Override off.

Coolant gauge, with the MOSFET stage on the sender wire:

  1. Force duty 110 (the CANNY program's 40 °C point) and note the needle; sweep 140 / 170 / 200 / 230.
  2. From two marks (Tc at duty A, Th at duty B): slope = (B − A)/(Th − Tc), offset = A − slope × Tc; enter slope × 100 and offset.
  3. Needle flicker or wander → raise PWM frequency. No response at all → driver stage / pull-up, not the numbers.
  4. Override off. Values are saved on A and pushed to B at once.

What must be established before any of this is wired

  1. Which Patrol cluster (Y60/Y61, petrol vs diesel). User states 4 pulses/rev (2026-09-21); confirm on the bench with the procedure above, since diesel clusters fed from an alternator W-terminal and petrol clusters fed from ignition differ (unverified). This fixes the frequency range and therefore the LEDC resolution/prescaler. → open-questions
  2. Whether the cluster's tach input has an internal pull-up, and to what voltage (meter it).
  3. The temp sender's resistance-vs-temperature curve as the gauge sees it (meter the original sender at cold/hot, or sweep a pot until the needle sits at known marks). The CANNY-era duty law in temp-stage-cfd is the starting table; it still needs a needle check with the new driver stage, plus the old circuit's series resistor and PWM frequency.
  4. Protocol change: add engine_rpm (u16, 1/min) and a valid_flags bit to the packet; bump the version on both repos → controller-link.
  5. The outage policy: what the needles do when the link is lost → link-redundancy.