First capture with the vehicle actually moving (raw/log_20260717_145930.txt, 1857 frames, filtered to 0x0BA + 0x1D2). Verified, closing yesterday's inference: ST_GR_GRB values 6/7/8/9/A observed directly = 2nd..6th. So 0x0BA byte 0's low nibble is a COMPLETE gear source on its own - P/R/N plus 1st..6th, reverse included. 0x1D2 is now needed only for the lever and the D/S/M mode, which 0x0BA does not carry. Value 4 is still unaccounted for. Also caught ST_CCLT (torque converter lockup clutch) live - 422 frames "controlling", clustered in the higher gears. This matters beyond curiosity: a closed clutch bolts the turbine to the impeller, so turbine == engine exactly. Any turbine/engine slip ratio read at road speed must check CCLT first or it will report "not engaged" for a perfectly healthy locked-up box. Decoded into driveline_t with that warning attached. Output shaft: identification now verified (rises monotonically 1139->16702 across gears 1->6, zero whenever the output is held). Scaling narrowed to x0.125 but NOT adopted - it implies a coherent 901->1872 rpm upshift schedule across five independent 6HP26X ratios, where raw-as-rpm would imply 7,200-15,000 rpm against a ~4,500 redline. Still rests on the unproven assumption that each gear's max output is its upshift point, so the field stays in raw counts. One capture including 0x1A2 settles it: turbine/output gives each ratio directly. Gearbox confirmed as ZF 6HP26X (user). Same gearset as the 6HP26, so the ratio table holds; the X is the xDrive output variant, which dates the donor to E60/E61 rather than E65 - the 7-series never took M57N with xDrive. That partly answers a standing open question, and raises a new one: the X box measures its output shaft upstream of the transfer case, so if a Patrol transfer case sits in the path its ratio enters the km/h conversion and changes with high/low range. Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
7.1 KiB
type, tags, updated
| type | tags | updated | ||||||
|---|---|---|---|---|---|---|---|---|
| source |
|
2026-07-17 |
Gearbox Lever & Gear Decode — 2026-07-16/17 (VERIFIED)
User-recorded per-detent captures of the Steptronic selector: raw/gear_box_can_revealings.csv (lever positions, 2026-07-16) and raw/gearbox_engaged_gear.csv (engaged gear 1–6 in both D and M/S, 2026-07-17). Together these verify 0x1D2 as the gear source and decode the lever, the engaged gear number, and the D/S/M mode.
Two IDs react to the gearbox: 0x1D2 (lever + engaged gear) and 0x0BA (the gearbox's own target gear). Both are needed — see the correction notice below.
0x1D2 (DLC 6) — lever + engaged gear ✅ VERIFIED
| Byte | Meaning | Values |
|---|---|---|
| 0 | Lever position | 0xE1=P · 0xD2=R · 0xB4=N · 0x78=D and S/M |
| 1 | Engaged gear | high nibble − 4 = gear; 0x0F = no numbered gear |
| 2 | unused | 0xFF |
| 3 | rolling counter | fluctuates — ignore |
| 4 | Mode | 0xF0=Drive(auto) · 0xF1=Sport · 0xF2=Manual |
| 5 | unused | 0xFF |
Byte 0 — lever position
Whole-byte codes, matching the documented E65/E90 values exactly, every one. (verified, 2026-07-16)
Byte 0 cannot split D from S/M (both 0x78) — Steptronic's S/M is a side-gate off D, so the fore/aft position is physically identical. Byte 4 does that job.
Byte 1 — engaged gear ✅ (2026-07-17)
The raw/gearbox_engaged_gear.csv capture resolves this. D1 is a clean arithmetic ladder, +16 per gear — the high nibble counts, the low nibble is a constant 0xF:
| D1 | hex | Engaged gear |
|---|---|---|
| 15 | 0x0F |
none (P / R / N) |
| 95 | 0x5F |
1 |
| 111 | 0x6F |
2 |
| 127 | 0x7F |
3 |
| 143 | 0x8F |
4 |
| 159 | 0x9F |
5 |
| 175 | 0xAF |
6 |
gear = (D1 >> 4) − 4
The D and M/S halves of the capture show identical D1 values for the same gear — which is the proof that this is engaged gear and not a lever field: the box is in 3rd whether it chose 3rd or the driver asked for it.
Corroborated by the earlier dump: E10F (P), D20F (R), B40F (N), 785F (D) — D at standstill = gear 1. And 0x0BA ST_GR_GRB uses the same ladder (5 = 1st), independently. (verified, 2026-07-17)
[!warning] Corrects the 2026-07-16 claim "D1 = drive-gate flag" This page previously called D1 a boolean gate (
0x0Fin P/R/N →0x5Fin D+S/M). Wrong — it was the gear number all along, reading 1 because the vehicle was stationary. Only two values were ever observed, so a flag looked like a reasonable fit. This also closes the "actual engaged gear needs a drive capture" item that this page previously listed as open — it didn't need a drive capture, it needed the lever held per-gear.
[!note] Reverse is not numbered D1 stays
0x0Fwith the lever in R and the box engaged (verified 2026-07-17:1D2 = D2 0F FF DC F0 FF).0x1D2D1 is blind to reverse. The engaged-R signal is0x0BAST_GR_GRB= 2.
Byte 4 — mode ✅ (2026-07-17)
| D4 | Mode |
|---|---|
0xF0 |
Drive — automatic |
0xF1 |
Sport — side gate, no manual input yet |
0xF2 |
Manual — driver has taken control via +/− |
From gearbox_engaged_gear.csv: M/S 1st = 0xF1, M/S 2nd–6th = 0xF2. Read with the user's note — "when I switch the lever to M/S the D4 has 241; I have not yet pulled the lever +; when I do it becomes 242" — this maps onto Steptronic behaviour: the side gate puts you in S, and the first +/− tap promotes you to M, where it stays.
[!warning] Corrects the 2026-07-16 claim "0xF2 = downshift (−)" This page previously called
0xF2a transient downshift event. Wrong — it persists across M/S gears 2 through 6, and events don't hold steady. It's a mode flag, not a shift pulse. The original observation (pushing the lever forward →0xF2) is still true but was misread: the downshift didn't signal0xF2, it promoted the box into Manual, which is what0xF2reports. This also dissolves the old "manual up-shift (+) value unconfirmed" question —+and−don't have distinct D4 codes; both simply mean Manual.
Recommended decode
lever = D0: 0xE1→P 0xD2→R 0xB4→N 0x78→D/S/M
mode = D4: 0xF0→auto Drive 0xF1→Sport 0xF2→Manual
gear = D1: 0x0F→none, else (D1>>4)−4 (1..6; never set for R)
engaged R → 0x0BA D0 low nibble == 2
0x0BA (DLC 8) — the gearbox's own target gear ⚠ previously dismissed in error
[!warning] Corrects the 2026-07-16 claim "
0x0BA— secondary, do NOT use" The 2026-07-16 dismissal rested on D7 colliding R=D=0xCF. D7 is not a gear field — per e65-reverse-engineering-repo it'sST_HYPP_ACV/alive-counter territory. The gear is in D0's low nibble (ST_GR_GRB), which does not collide and which carries a distinct R code that0x1D2has nowhere.0x0BAis not redundant — it is the only source of engaged reverse and the only source of output-shaft motion. Do use it.Similarly "D5/D6 fluctuate so there are no values" — D5 =
CHKSM_GRB(checksum), D6 =ALIV_GRB(alive counter). The observation was correct; the fluctuation is by design, not noise.
ST_GR_GRB = D0 low nibble: 1=N, 2=R, 3=P, 5–A=gears 1–6, 0xF=invalid. All of 1/2/3/5/6/7/8/9/A verified — 5–A confirmed directly by the 2026-07-17 drive capture (can-capture-2026-07-17-drive), retiring the earlier inference. Value 4 still unobserved.
This makes 0x0BA D0 a complete gear source on its own — P/R/N and 1st–6th from one nibble, reverse included. 0x1D2 is still required for the lever (what the driver selected) and the mode (D/S/M), neither of which 0x0BA carries.
D0 bits 6–7 = ST_CCLT, the torque converter lockup clutch (0=disengaged, 1=controlled, 2=closed) — seen live in the higher gears.
0x0BA D3/D4 carry what is almost certainly output shaft speed — undocumented in the source repo, zero in every stationary frame, non-zero the moment the wheels turn. This is the project's only road-speed signal. → driveline-speed-signals
Lever vs box: the UX cross-check
0x1D2 D0 = what the driver selected; 0x0BA ST_GR_GRB = what the box intends. Disagreement means the box refused the request — a real fault worth surfacing on the display. Neither, however, is proof of mechanical engagement; for that, use turbine speed (0x1A2), which physically collapses when the box loads up. Full treatment: driveline-speed-signals.
Still open
- Value
4in theST_GR_GRBladder unaccounted for. 0x0BAD3/D4 scaling — ×0.125 is now a strong hypothesis but not measured → driveline-speed-signals.0x1D2D0 =0xF0, an unrecognized lever code seen once in a discarded log; absent from the drive capture. Probably an EGS-not-initialised transient. The firmware rejects it asGEAR_UNKNOWN, which is the right conservative behaviour either way.
Related
can-id-candidates · driveline-speed-signals · e65-reverse-engineering-repo · can-capture-2026-07-15 · can-bus-integration