feat: bootstrap wiki for Anfu home EV charger OCPP integration project

- Created initial wiki structure with CLAUDE.md schema, index.md, and log.md.
- Ingested findings and requirements document into the wiki.
- Added concepts for authorization methods, network topology, OCPP protocol, and troubleshooting.
- Documented entities including the Anfu charger, JC-6620 controller, and CSMS toolkit.
- Established configuration files for Obsidian app settings and workspace layout.
- Implemented core plugins and appearance settings for the wiki.
This commit is contained in:
2026-07-09 15:29:26 +02:00
commit 2e5960fae3
26 changed files with 1431 additions and 0 deletions
+32
View File
@@ -0,0 +1,32 @@
---
type: entity
updated: 2026-07-09
tags: [hardware]
---
# Anfu Home Charger (charging pile)
The physical home EV charger this whole project revolves around. It is not a single device but a small network of three, behind its own Four-Faith router (see [[network-topology]]). Per [[2026-07-09-findings-and-requirements]]:
- **[[jc-6620|JC-6620]]** (`192.168.2.228`) — OCPP communication controller; the OCPP client that dials the CSMS
- **EV charging controller** (`192.168.2.118`, DHCP) — the main control board that actually manages charging; the JC-6620 talks to it on port 2403
- **Touchscreen** — where all charger-side configuration happens
## Touchscreen configuration (working values)
| Screen | Setting | Value |
|---|---|---|
| General Settings → Charger INEO | URL | `ws://<CSMS-IP>:9000` |
| General Settings → Charger INEO | ChargerID | any |
| Back Office → Universal | Billing Mode | **`BackgroundBilling`** (required — see [[troubleshooting]]) |
| Back Office → Universal | Communication Method | `Ethernet` (not 4G/SIM) |
| Back Office → Universal | JC-6620 IP / Port | `192.168.2.228` / `2403` |
> [!warning] Power-cycle required
> URL or network changes only take effect after power-cycling the pile.
## Capabilities in question
- ✅ OCPP 1.6J over WebSocket — verified working
- ⚠️ Autocharge (per-vehicle idTag on plug-in) — needs a physical test; see [[authorization]]
- ❌ True ISO 15118 Plug & Charge — unlikely on a basic AC unit