refactor(backend): single SQLite store — config.json eliminated
backend.db (renamed from sessions.db) now holds everything: the sessions
and samples tables plus a settings table with the app-state sections
(users, allowlist, relays, chargers, learn_mode, session_secret) as JSON
blobs. All mutations go through the API/panel and take effect immediately;
there is no config file and no hand-edit-then-restart ambiguity.
- legacy config.json auto-imports into the db on first start (renamed to
config.json.migrated as a backup)
- new admin endpoints: PUT/DELETE /api/relays/{name} (how tinytuya wizard
results are registered now) and PUT /api/chargers/{cp_id} (panel labels)
- BACKEND_DB env override so tests run on an isolated temp database
- smoke test: 45 checks, real db verified untouched
This commit is contained in:
@@ -6,7 +6,7 @@ tags: [auth, requirements]
|
||||
|
||||
# Authorization Methods
|
||||
|
||||
The three planned ways to authorize a charging session. Architecturally they all collapse to one gate: **`decide(id_tag, connector)` in the [[backend]]** (`backend/csms.py`; formerly `station.py` in [[csms-toolkit]]) returns Accepted/Rejected against the allowlist in `backend/config.json`. Per [[2026-07-09-findings-and-requirements]]. On top of these charger-side methods sits the **per-user API permission system** (last section).
|
||||
The three planned ways to authorize a charging session. Architecturally they all collapse to one gate: **`decide(id_tag, connector)` in the [[backend]]** (`backend/csms.py`; formerly `station.py` in [[csms-toolkit]]) returns Accepted/Rejected against the allowlist in `backend.db`. Per [[2026-07-09-findings-and-requirements]]. On top of these charger-side methods sits the **per-user API permission system** (last section).
|
||||
|
||||
## 1. RFID cards — ✅ verified live (2026-07-09)
|
||||
|
||||
@@ -55,7 +55,7 @@ A mobile-friendly web control panel (no app store):
|
||||
|
||||
The [[backend]] now has real multi-user authorization on top of the three methods above, because not every household member may control everything. Requirement (owner, 2026-07-11): some users control gun 1 only, some gun 2, some only certain [[wifi-relays|relays]].
|
||||
|
||||
- **Users** live in `backend/config.json` → `"users"`: username + PBKDF2 password hash + scope list + a personal `id_tag` (`app-<name>`) used for their remote starts, so charging sessions are **attributable per person**.
|
||||
- **Users** live in the `settings` table of `backend.db`: username + PBKDF2 password hash + scope list + a personal `id_tag` (`app-<name>`) used for their remote starts, so charging sessions are **attributable per person**.
|
||||
- **Login**: `POST /api/login` (username/password) → 30-day HMAC-signed session, delivered as an HttpOnly cookie (for the PWA) and as a bearer token (for curl). Stateless — survives backend restarts; deleting a user kills their sessions.
|
||||
- **Scopes** (fnmatch wildcards work):
|
||||
|
||||
@@ -67,7 +67,7 @@ The [[backend]] now has real multi-user authorization on top of the three method
|
||||
| `admin` | everything, incl. allowlist/user CRUD, learn-mode flip, setconfig, events |
|
||||
|
||||
- **Bootstrap**: zero users = open API (startup warns loudly). First user: `venv\Scripts\python -m backend.users add <name> --scopes admin`.
|
||||
- ✅ Verified by the 28-check smoke test (login, wrong password, cookie + bearer, per-scope 403s, relay visibility filtering, user CRUD, session invalidation on delete). ⚠️ Not yet exercised from a real browser/PWA (doesn't exist yet).
|
||||
- ✅ Verified by the 45-check smoke test (login, wrong password, cookie + bearer, per-scope 403s, relay visibility filtering, user CRUD, session invalidation on delete). ⚠️ Not yet exercised from a real phone browser.
|
||||
|
||||
This resolves the ❓ "web app auth" open decision in [[overview]]: username+password with per-resource scopes, chosen over plain tokens by the owner.
|
||||
|
||||
|
||||
@@ -16,12 +16,11 @@ backend/ (run: venv\Scripts\python -m backend.main, from the repo root)
|
||||
├── routes.py REST under /api/* (login + per-scope permission checks)
|
||||
├── users.py passwords (PBKDF2), sessions (HMAC), scope matcher, user CLI
|
||||
├── store.py SQLite session store: who charged, when, how many kWh + meter samples
|
||||
├── config.py config.json load/save
|
||||
├── config.py app-state sections (users/allowlist/relays/chargers), db-backed
|
||||
├── journal.py events.jsonl + seen_tags.json (raw ground truth)
|
||||
├── static/ the web panel PWA (index.html, manifest, service worker, icon)
|
||||
├── config.json users + allowlist + relay registry — GITIGNORED (password
|
||||
│ hashes, session secret, Tuya local keys); see config.example.json
|
||||
└── sessions.db SQLite (gitignored, auto-created)
|
||||
└── backend.db THE one store (SQLite, gitignored): sessions + samples +
|
||||
settings (users, allowlist, relays, chargers, session secret)
|
||||
```
|
||||
|
||||
## Surfaces (all on :9000 — the touchscreen URL never changes)
|
||||
@@ -44,10 +43,11 @@ backend/ (run: venv\Scripts\python -m backend.main, from the repo root)
|
||||
- **Multi-charger by design**: a second charger only needs the same URL with a unique ChargerID; scopes, sessions, card restrictions, and the panel are all keyed by charger id. Gun display names come from the `"chargers"` config section (not hardcoded).
|
||||
- **Multi-user auth** (2026-07-11, replaced the interim `api_token`): username/password users with permission scopes — `charger:<cp>:<gun>`, `relay:<name>`, `admin` — full model in [[authorization]]. Stdlib crypto only (PBKDF2 + HMAC sessions). Zero users = open API (startup warns); bootstrap via `python -m backend.users add <name> --scopes admin`.
|
||||
- Remote starts run under the calling user's own idTag (`app-<name>`, auto-enrolled) → per-person session attribution.
|
||||
- **Consumption tracking** (`store.py`, 2026-07-11): every `StartTransaction` opens a row in `sessions.db` with a resolved "who" (allowlist name or username); `StopTransaction` closes it and computes Wh from the meter diff; `MeterValues` rows land in a `samples` table (energy/power/SoC, kW→W normalized). Transaction ids continue from `MAX(tx)` across restarts, and stop-by-tx falls back to the store so sessions running through a backend restart stay stoppable.
|
||||
- **Consumption tracking** (`store.py`, 2026-07-11): every `StartTransaction` opens a row in `backend.db` with a resolved "who" (allowlist name or username); `StopTransaction` closes it and computes Wh from the meter diff; `MeterValues` rows land in a `samples` table (energy/power/SoC, kW→W normalized). Transaction ids continue from `MAX(tx)` across restarts, and stop-by-tx falls back to the store so sessions running through a backend restart stay stoppable.
|
||||
- Relay calls are blocking tinytuya I/O, run via `asyncio.to_thread` so the OCPP socket never stalls.
|
||||
- Venv at repo root (`../venv/`, Python 3.13); deps pinned in `backend/requirements.txt` (fastapi, uvicorn, websockets, ocpp, tinytuya) — the auth system added none.
|
||||
- ✅ Smoke-tested 2026-07-11 (37 checks): REST surface, allowlist CRUD incl. gun-restricted cards, login/sessions/scopes, user CRUD, the full consumption pipeline (start → meter sample → stop → kWh → visibility filtering), static panel serving, and a fake charge point over the real WS route. ⚠️ Not yet run against the live charger or a real phone browser; relays unconfigured until the [[wifi-relays|key extraction]] is done.
|
||||
- ✅ Smoke-tested 2026-07-11 (45 checks, isolated temp db via the `BACKEND_DB` env override): REST surface, allowlist CRUD incl. gun-restricted cards, login/sessions/scopes, user/relay/charger CRUD, the full consumption pipeline (start → meter sample → stop → kWh → visibility filtering), static panel serving, and a fake charge point over the real WS route.
|
||||
- ✅ **Live charger connected** (2026-07-11 evening): `eu092025` dials the backend (events.jsonl). ⚠️ Panel not yet exercised from a real phone; relays unconfigured until the [[wifi-relays|key extraction]] is done.
|
||||
|
||||
## Web panel notes
|
||||
|
||||
|
||||
@@ -19,7 +19,7 @@ Local control needs each device's **id + local key**, extracted once via Tuya's
|
||||
1. Create a (free) account at `iot.tuya.com` → Cloud → create a project (data center matching the SmartLife account region).
|
||||
2. Link the SmartLife app account to the project (Devices → Link App Account → scan QR in SmartLife).
|
||||
3. From the repo root: `venv\Scripts\python -m tinytuya wizard` — enter the project's API id/secret; it dumps every paired device's `id`, `key`, `ip`, and protocol `version`.
|
||||
4. Copy each relay into `backend/config.json` → `"relays"` (shape in `config.example.json`). The Tuya cloud account is never needed again unless a device is re-paired (**re-pairing regenerates the local key**).
|
||||
4. Register each relay via `PUT /api/relays/<name>` (admin; interactive form at `/docs`) with its `id`, `key`, `ip`, `version`. The Tuya cloud account is never needed again unless a device is re-paired (**re-pairing regenerates the local key**).
|
||||
|
||||
Recommended: DHCP reservations for the relays and pinned `"ip"` entries in the config — `"ip": "auto"` works via UDP broadcast discovery but is slower and only finds relays on the same L2 segment as the backend host (❓ verify which subnet the relays are on vs. the future always-on host, see [[network-topology]]).
|
||||
|
||||
|
||||
@@ -75,3 +75,7 @@ Owner requirement: button-push start when a gun is ready (and permitted) + "who
|
||||
## [2026-07-11] meta | Cards linked to users; multi-charger gaps closed
|
||||
|
||||
Owner requirements: cards must belong to a person (not float around as "RFID card A (tapped first...)"), and adding a second charger must be clean. Allowlist entries now take "user" (sessions attribute to the person; owner sees their card's history) and charger-qualified "guns": ["eu092025:2"] (fnmatch; replaces the charger-blind "connectors" field). Gun display names moved from hardcoded panel JS to a "chargers" config section served via /api/status. Adding a charger = point it at the same URL with a unique ChargerID + grant charger:<id>:<gun> scopes. Panel admin tab: owner dropdown + guns field. Smoke test 37 -> 42 checks. Updated [[authorization]], [[backend]].
|
||||
|
||||
## [2026-07-11] meta | config.json eliminated — one SQLite store (backend.db)
|
||||
|
||||
Owner pushback: two persistence stores (sessions.db + a config.json that doubled as a mutable datastore) was one too many, with confusing hand-edit-needs-restart semantics. Now everything lives in backend.db (renamed from sessions.db): sessions + samples tables plus a settings table holding the app-state sections (users, allowlist, relays, chargers, learn_mode, session_secret) as JSON blobs. All changes go through the API/panel and apply immediately; nothing to hand-edit. Legacy config.json auto-imports on first start (kept as config.json.migrated) — julian + cards + charger labels migrated. New admin endpoints PUT/DELETE /api/relays/{name} and PUT /api/chargers/{id} replace file editing (tinytuya wizard results now enter via /docs). Smoke test isolated via BACKEND_DB env override; 45 checks. Also: live cutover confirmed — eu092025 connected to the backend this evening. Updated [[backend]], [[authorization]], [[wifi-relays]], [[overview]].
|
||||
|
||||
+3
-3
@@ -12,7 +12,7 @@ tags: [synthesis]
|
||||
|
||||
**Connectivity: ✅ solved.** The [[jc-6620|JC-6620]] controller inside the [[anfu-charger|charging pile]] reliably dials out to the CSMS — verified both on the charger's own LAN (`192.168.2.114:9000`) and across the NAT boundary on the WAN subnet (`10.0.10.203:9000`). Getting here required the fixes catalogued in [[troubleshooting]]; the network layout is in [[network-topology]].
|
||||
|
||||
**Software: production [[backend]] built (2026-07-11), including the web panel.** `station.py` was ported into the `../backend/` package: one FastAPI process on port 9000 = CSMS WebSocket + `/api/*` (charger control, allowlist CRUD, runtime learn-mode flip) + [[wifi-relays|Tuya relay]] on/off/toggle + **multi-user auth** (username/password, per-resource scopes: gun 1 / gun 2 / per-relay / admin, per-gun-restrictable RFID cards — [[authorization]]) + **consumption tracking** (SQLite: who charged, when, how many kWh, per-minute meter samples) + the **PWA control panel** at `/` (login, scope-filtered start/stop buttons, relay toggles, history, admin). Smoke-tested (37 checks incl. a fake charge point over the real WS route); ⚠️ not yet run against the live charger or a real phone. The [[csms-toolkit]] (`../discovering/`) remains as diagnostic tooling.
|
||||
**Software: production [[backend]] built (2026-07-11), including the web panel.** `station.py` was ported into the `../backend/` package: one FastAPI process on port 9000 = CSMS WebSocket + `/api/*` (charger control, allowlist CRUD, runtime learn-mode flip) + [[wifi-relays|Tuya relay]] on/off/toggle + **multi-user auth** (username/password, per-resource scopes: gun 1 / gun 2 / per-relay / admin, per-gun-restrictable RFID cards — [[authorization]]) + **consumption tracking** (SQLite: who charged, when, how many kWh, per-minute meter samples) + the **PWA control panel** at `/` (login, scope-filtered start/stop buttons, relay toggles, history, admin). Smoke-tested (45 checks incl. a fake charge point over the real WS route); ✅ live charger connects to it since 2026-07-11 evening; ⚠️ panel untested from a real phone. All state lives in one SQLite file (`backend.db`) — no config file, every change via API/panel takes effect immediately. The [[csms-toolkit]] (`../discovering/`) remains as diagnostic tooling.
|
||||
|
||||
**Capabilities: ✅ known.** The live probe ([[2026-07-09-discovery-eu092025]]) identified the pile as SimpleCharge "MultiSocketCharger" (fw 1.24.0620.1, OCPP ID `eu092025`) with **two guns**, RemoteTrigger (verified), SmartCharging, Reservation, a 6-entry local auth list, and per-minute meter data including SoC. Only Autocharge remains unknown (physical test pending; `MacEnabled` is a lead — [[authorization]]).
|
||||
|
||||
@@ -25,9 +25,9 @@ Hardware surprise: this is a **DC-capable multi-standard charger** (gun 1 EU, gu
|
||||
|
||||
## What's next
|
||||
|
||||
1. **Cut the live charger over to the [[backend]]** — stop `station.py`, run `python -m backend.main` from the repo root, verify the JC-6620 reconnects and a card tap still authorizes (allowlist already migrated to `backend/config.json`).
|
||||
1. ~~Cut the live charger over to the backend~~ — ✅ done 2026-07-11 evening: `eu092025` connects to `python -m backend.main` (verified in events.jsonl). Remaining: a card tap + a panel button-push on the live charger.
|
||||
2. **Create the real users** — `python -m backend.users add <name> --scopes ...` for each household member (the API stays open until the first user exists).
|
||||
3. **Extract the Tuya local keys** (`tinytuya wizard` — steps in [[wifi-relays]]) and fill `backend/config.json` → relays become controllable.
|
||||
3. **Extract the Tuya local keys** (`tinytuya wizard` — steps in [[wifi-relays]]) and register them via `PUT /api/relays/<name>` → relays become controllable.
|
||||
4. **Flip learn mode off** — both cards + the app token are enrolled; switchable from the panel's Admin tab or `POST /api/mode?learn=false`, no restart. (Only wait if more cards need tapping.)
|
||||
5. **Test the panel from a phone** — it's built and serving at `http://<host>:9000/`; verify login, a real button-push start on a ready gun, and add-to-home-screen over [[netbird|NetBird]].
|
||||
6. **Resolve the ❓ remote-stop restart question** — did the gun-2 session auto-restart from auth cache after RemoteStop, or was the card re-tapped? Affects the app's Stop button UX ([[authorization]]).
|
||||
|
||||
Reference in New Issue