Files
charging_station/wiki/raw/FINDINGS_AND_REQUIREMENTS.md
T
julian 2e5960fae3 feat: bootstrap wiki for Anfu home EV charger OCPP integration project
- Created initial wiki structure with CLAUDE.md schema, index.md, and log.md.
- Ingested findings and requirements document into the wiki.
- Added concepts for authorization methods, network topology, OCPP protocol, and troubleshooting.
- Documented entities including the Anfu charger, JC-6620 controller, and CSMS toolkit.
- Established configuration files for Obsidian app settings and workspace layout.
- Implemented core plugins and appearance settings for the wiki.
2026-07-09 15:29:26 +02:00

107 lines
5.6 KiB
Markdown
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
# Anfu Home Charger — OCPP Integration: Findings & Requirements
_Last updated: 2026-07-09_
## 1. Goal
Run a **private, self-hosted OCPP 1.6J backend (CSMS)** for a home EV charger.
No billing, no public charging. Authorization should be possible via:
1. **RFID cards** already owned (tap to charge).
2. **By vehicle / chassis**, if the hardware supports it (see §7 — has a caveat).
3. A **mobile / web app** (start/stop charging), hosted securely behind an existing
**NetBird** private network.
## 2. Hardware & Topology
The charging pile contains three networked devices behind its own router:
```
10.0.10.0/24 (upstream / WAN — main gateway lives here)
│
┌──┴───────────────┐
│ Four-Faith router │ WAN gets a 10.0.10.x address; NAT boundary
└──┬───────────────┘
│ LAN = 192.168.2.1 (mask 255.255.255.0)
├── 192.168.2.228 JC-6620 OCPP communication controller ← the OCPP client
├── 192.168.2.118 EV charging controller (main control board), DHCP
└── 192.168.2.114 maintenance PC (LAN side)
```
- Wiring is the manufacturer's **star** topology: the EV charging controller **and** the
JC-6620's fixed-IP (right) port each connect to a router LAN1–4 port.
- **The JC-6620 (192.168.2.228) is the device that opens the outbound OCPP WebSocket**
to the CSMS. It talks to the EV controller locally on port **2403**.
## 3. CSMS software (this repo)
| File | Purpose |
|------|---------|
| `csms.py` | Minimal OCPP 1.6J server — accepts everything, logs raw frames. Discovery/tester. |
| `rawlisten.py` | Dumb TCP listener on :9000 — shows whether *any* bytes arrive. Fallback diagnostic. |
| `station.py` | **The real controller.** Allowlist-based auth + "learn mode" + hooks for remote start/stop. |
| `station_config.json` | `{ "learn_mode": bool, "authorized": { "<idTag>": {name, kind} } }` |
| `seen_tags.json` | Auto-recorded log of every idTag observed (for discovery). |
Runtime: Python venv with `websockets` (16.0) + `ocpp`. Server listens on
`ws://0.0.0.0:9000/<chargePointId>`.
## 4. Charger-side configuration (touchscreen)
- **General Settings → Charger INEO:** `URL = ws://<CSMS-IP>:9000`, `ChargerID = <any>`
- **Back Office → Universal:** `Billing Mode = BackgroundBilling`,
`Communication Method = Ethernet`, `JC-6620 IP = 192.168.2.228`, `Port = 2403`
- **JC-6620 network config (静态 IP):** IP `192.168.2.228`, mask `255.255.255.0`,
**default gateway (默认网关) `192.168.2.1`** (DNS not needed — CSMS is a bare IP).
## 5. Findings / gotchas (hard-won — check these first if it breaks)
1. **CSMS host firewall** must allow inbound **TCP 9000**. Windows silently drops
otherwise → looks like "charger never connects."
2. **`Billing Mode` must be `BackgroundBilling`.** Until it is, the OCPP client never
dials out *at all* (zero TCP SYNs). This was the blocker for the first connection.
3. **`Communication Method` must be `Ethernet`** (not 4G/SIM).
4. **URL / network changes require a pile power-cycle** to take effect.
5. **JC-6620 default gateway must be `192.168.2.1`.** It shipped as `192.168.2.228`
(pointing at itself) — which reaches a *same-subnet* CSMS but **cannot route to the
WAN**. This is why a `192.168.2.x` CSMS worked but a `10.0.10.x` CSMS did not, until
the gateway was fixed.
6. **No port-forwarding needed on the charger router.** The JC-6620 is the *client* and
dials outbound; NAT handles LAN→WAN. Port-forwarding would only matter for inbound.
7. **The CSMS host needs a stable IP.** The touchscreen URL is hardcoded, so the host
must not change address (static IP or a DHCP reservation).
## 6. Verified working
- ✅ **Local CSMS** at `192.168.2.114:9000` — JC-6620 connected, full BootNotification
exchange.
- ✅ **Remote / WAN CSMS** at `10.0.10.203:9000` (on the router's WAN subnet) — connected
after fixing the JC-6620 default gateway. Confirms the CSMS can live upstream / off-subnet.
## 7. Requirements to build next
All three authorization methods funnel through one gate in `station.py` —
`decide(id_tag)` → Accepted/Rejected against the allowlist. So the build is:
- **Allowlist enforcement** — already implemented. Learn mode captures ids; flip
`learn_mode=false` to enforce.
- **RFID cards** — tap each card once in learn mode, harvest its idTag from
`seen_tags.json`, add to `authorized` with a name. Works with existing cards.
- **By vehicle / chassis** — ⚠️ **needs a physical test.** True VIN / Plug & Charge
(ISO 15118) is unlikely on a basic AC unit. The lighter option is **Autocharge**: some
chargers auto-send a per-vehicle idTag on plug-in (no card). Test = plug car in without
tapping; if a stable idTag appears in `seen_tags.json`, whitelist it as `kind:"car"`.
If nothing appears, "by chassis" is not achievable on this hardware.
- **Mobile / web app** — a web control panel (mobile-friendly, no app store) exposing
Start/Stop via OCPP `RemoteStartTransaction` / `RemoteStopTransaction`, plus live status
and clickable allowlist management. Bind to `0.0.0.0`, reach it over **NetBird**.
Optional access token/PIN for defense-in-depth.
## 8. Open decisions (for you)
- **Final host** for the always-on CSMS + app: the LAN PC, the `10.0.10.203` machine, or
a dedicated always-on box (e.g. a Pi on the charger LAN joined to NetBird)?
- **Web app auth:** rely on NetBird network isolation only, or also require a PIN/token?
- **Autocharge:** do we run the plug-in test to see if "by chassis" is even possible?
- **IP stability:** static IP vs DHCP reservation for the chosen host.