Files
charging_station/wiki/entities/backend.md
T
julian 56c9020d9f refactor(backend): single SQLite store — config.json eliminated
backend.db (renamed from sessions.db) now holds everything: the sessions
and samples tables plus a settings table with the app-state sections
(users, allowlist, relays, chargers, learn_mode, session_secret) as JSON
blobs. All mutations go through the API/panel and take effect immediately;
there is no config file and no hand-edit-then-restart ambiguity.

- legacy config.json auto-imports into the db on first start (renamed to
  config.json.migrated as a backup)
- new admin endpoints: PUT/DELETE /api/relays/{name} (how tinytuya wizard
  results are registered now) and PUT /api/chargers/{cp_id} (panel labels)
- BACKEND_DB env override so tests run on an isolated temp database
- smoke test: 45 checks, real db verified untouched
2026-07-11 20:15:38 +02:00

59 lines
5.8 KiB
Markdown
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
---
type: entity
updated: 2026-07-11
tags: [software, csms, backend, relays, auth]
---
# Backend (`../backend/`)
The production successor to [[csms-toolkit|station.py]] (built 2026-07-11): one FastAPI/uvicorn process on **port 9000** that is both the private CSMS for the [[anfu-charger]] and the controller for the [[wifi-relays|Tuya WiFi relays]] — phases 1–2 of the [[architecture-plan]].
```
backend/ (run: venv\Scripts\python -m backend.main, from the repo root)
├── main.py app assembly + entrypoint (uvicorn :9000), serves the panel
├── csms.py OCPP 1.6J ChargePoint handlers, decide() gate, remote start/stop
├── relays.py tinytuya local control of the SmartLife relays
├── routes.py REST under /api/* (login + per-scope permission checks)
├── users.py passwords (PBKDF2), sessions (HMAC), scope matcher, user CLI
├── store.py SQLite session store: who charged, when, how many kWh + meter samples
├── config.py app-state sections (users/allowlist/relays/chargers), db-backed
├── journal.py events.jsonl + seen_tags.json (raw ground truth)
├── static/ the web panel PWA (index.html, manifest, service worker, icon)
└── backend.db THE one store (SQLite, gitignored): sessions + samples +
settings (users, allowlist, relays, chargers, session secret)
```
## Surfaces (all on :9000 — the touchscreen URL never changes)
- `ws://<host>:9000/<ChargerID>` — OCPP WebSocket (catch-all path, the JC-6620 dials in)
- `GET /` — **the web panel** (mobile-first PWA, vanilla JS, self-contained; login → tabs Control / History / Admin, buttons filtered by the user's scopes; polls `/api/status` every 5 s)
- `POST /api/login|logout`, `GET /api/me` — username/password → 30-day session (cookie + bearer)
- `GET /api/sessions?limit&cp&connector` — **charging history: who / when / kWh** (visibility: own sessions + guns within scope; admin sees all); `GET /api/sessions/{tx}/samples` — per-minute energy/power/SoC for charts
- `GET /api/status` — mode, connected chargers, gun states, active transactions, auth events, relays (filtered to what the caller may control)
- `GET /api/events?limit&event=` — tail the journal (admin)
- `POST /api/charger/start|stop[/{tx}]|unlock/{n}` — gun-scoped; `trigger/{...}|setconfig|probe` — admin
- `GET/PUT/DELETE /api/allowlist[/{idTag}]` + `POST /api/mode?learn=` — admin; **learn mode flips at runtime, no restart**
- `GET/PUT/DELETE /api/users[/{name}]` — user CRUD (admin), enables a PWA admin page later
- `GET /api/relays[?live=true]`, `GET /api/relays/{name}`, `POST /api/relays/{name}/on|off|toggle` — relay-scoped
- `/docs` — interactive OpenAPI docs
## Design facts
- Carried over from the proven discovery code: the `decide()` gate ([[authorization]]) — now with card→user linking (`"user"`) and charger-qualified gun restriction (`"guns": ["eu092025:2"]`, fnmatch) — the `_WSAdapter` WebSocket bridge, learn mode, the JSONL event journal. `DataTransfer` frames are journaled too (the VIN long-shot lead in [[authorization]]).
- **Multi-charger by design**: a second charger only needs the same URL with a unique ChargerID; scopes, sessions, card restrictions, and the panel are all keyed by charger id. Gun display names come from the `"chargers"` config section (not hardcoded).
- **Multi-user auth** (2026-07-11, replaced the interim `api_token`): username/password users with permission scopes — `charger:<cp>:<gun>`, `relay:<name>`, `admin` — full model in [[authorization]]. Stdlib crypto only (PBKDF2 + HMAC sessions). Zero users = open API (startup warns); bootstrap via `python -m backend.users add <name> --scopes admin`.
- Remote starts run under the calling user's own idTag (`app-<name>`, auto-enrolled) → per-person session attribution.
- **Consumption tracking** (`store.py`, 2026-07-11): every `StartTransaction` opens a row in `backend.db` with a resolved "who" (allowlist name or username); `StopTransaction` closes it and computes Wh from the meter diff; `MeterValues` rows land in a `samples` table (energy/power/SoC, kW→W normalized). Transaction ids continue from `MAX(tx)` across restarts, and stop-by-tx falls back to the store so sessions running through a backend restart stay stoppable.
- Relay calls are blocking tinytuya I/O, run via `asyncio.to_thread` so the OCPP socket never stalls.
- Venv at repo root (`../venv/`, Python 3.13); deps pinned in `backend/requirements.txt` (fastapi, uvicorn, websockets, ocpp, tinytuya) — the auth system added none.
- ✅ Smoke-tested 2026-07-11 (45 checks, isolated temp db via the `BACKEND_DB` env override): REST surface, allowlist CRUD incl. gun-restricted cards, login/sessions/scopes, user/relay/charger CRUD, the full consumption pipeline (start → meter sample → stop → kWh → visibility filtering), static panel serving, and a fake charge point over the real WS route.
- ✅ **Live charger connected** (2026-07-11 evening): `eu092025` dials the backend (events.jsonl). ⚠️ Panel not yet exercised from a real phone; relays unconfigured until the [[wifi-relays|key extraction]] is done.
## Web panel notes
Vanilla JS on purpose (no framework, no CDN — the panel must work with NetBird-only reachability). Start button enables only when the gun reports `Preparing`/`Available` **and** the user holds that gun's scope. Gun cards show who is charging and since when; History tab lists who/when/kWh; Admin tab (admin scope only) manages allowlist (incl. per-gun cards + "seen but not enrolled" quick-enroll), users, and the learn/enforce toggle. Trivial service worker = installable ("add to home screen") without cache-staleness risk.
## Deliberately deferred
SSE live push (the panel polls), per-session charts from the `samples` table (data is already collected), auto-interrogation on connect (manual `POST /api/charger/probe`).