56c9020d9f
backend.db (renamed from sessions.db) now holds everything: the sessions
and samples tables plus a settings table with the app-state sections
(users, allowlist, relays, chargers, learn_mode, session_secret) as JSON
blobs. All mutations go through the API/panel and take effect immediately;
there is no config file and no hand-edit-then-restart ambiguity.
- legacy config.json auto-imports into the db on first start (renamed to
config.json.migrated as a backup)
- new admin endpoints: PUT/DELETE /api/relays/{name} (how tinytuya wizard
results are registered now) and PUT /api/chargers/{cp_id} (panel labels)
- BACKEND_DB env override so tests run on an isolated temp database
- smoke test: 45 checks, real db verified untouched
59 lines
5.8 KiB
Markdown
59 lines
5.8 KiB
Markdown
---
|
||
type: entity
|
||
updated: 2026-07-11
|
||
tags: [software, csms, backend, relays, auth]
|
||
---
|
||
|
||
# Backend (`../backend/`)
|
||
|
||
The production successor to [[csms-toolkit|station.py]] (built 2026-07-11): one FastAPI/uvicorn process on **port 9000** that is both the private CSMS for the [[anfu-charger]] and the controller for the [[wifi-relays|Tuya WiFi relays]] — phases 1–2 of the [[architecture-plan]].
|
||
|
||
```
|
||
backend/ (run: venv\Scripts\python -m backend.main, from the repo root)
|
||
├── main.py app assembly + entrypoint (uvicorn :9000), serves the panel
|
||
├── csms.py OCPP 1.6J ChargePoint handlers, decide() gate, remote start/stop
|
||
├── relays.py tinytuya local control of the SmartLife relays
|
||
├── routes.py REST under /api/* (login + per-scope permission checks)
|
||
├── users.py passwords (PBKDF2), sessions (HMAC), scope matcher, user CLI
|
||
├── store.py SQLite session store: who charged, when, how many kWh + meter samples
|
||
├── config.py app-state sections (users/allowlist/relays/chargers), db-backed
|
||
├── journal.py events.jsonl + seen_tags.json (raw ground truth)
|
||
├── static/ the web panel PWA (index.html, manifest, service worker, icon)
|
||
└── backend.db THE one store (SQLite, gitignored): sessions + samples +
|
||
settings (users, allowlist, relays, chargers, session secret)
|
||
```
|
||
|
||
## Surfaces (all on :9000 — the touchscreen URL never changes)
|
||
|
||
- `ws://<host>:9000/<ChargerID>` — OCPP WebSocket (catch-all path, the JC-6620 dials in)
|
||
- `GET /` — **the web panel** (mobile-first PWA, vanilla JS, self-contained; login → tabs Control / History / Admin, buttons filtered by the user's scopes; polls `/api/status` every 5 s)
|
||
- `POST /api/login|logout`, `GET /api/me` — username/password → 30-day session (cookie + bearer)
|
||
- `GET /api/sessions?limit&cp&connector` — **charging history: who / when / kWh** (visibility: own sessions + guns within scope; admin sees all); `GET /api/sessions/{tx}/samples` — per-minute energy/power/SoC for charts
|
||
- `GET /api/status` — mode, connected chargers, gun states, active transactions, auth events, relays (filtered to what the caller may control)
|
||
- `GET /api/events?limit&event=` — tail the journal (admin)
|
||
- `POST /api/charger/start|stop[/{tx}]|unlock/{n}` — gun-scoped; `trigger/{...}|setconfig|probe` — admin
|
||
- `GET/PUT/DELETE /api/allowlist[/{idTag}]` + `POST /api/mode?learn=` — admin; **learn mode flips at runtime, no restart**
|
||
- `GET/PUT/DELETE /api/users[/{name}]` — user CRUD (admin), enables a PWA admin page later
|
||
- `GET /api/relays[?live=true]`, `GET /api/relays/{name}`, `POST /api/relays/{name}/on|off|toggle` — relay-scoped
|
||
- `/docs` — interactive OpenAPI docs
|
||
|
||
## Design facts
|
||
|
||
- Carried over from the proven discovery code: the `decide()` gate ([[authorization]]) — now with card→user linking (`"user"`) and charger-qualified gun restriction (`"guns": ["eu092025:2"]`, fnmatch) — the `_WSAdapter` WebSocket bridge, learn mode, the JSONL event journal. `DataTransfer` frames are journaled too (the VIN long-shot lead in [[authorization]]).
|
||
- **Multi-charger by design**: a second charger only needs the same URL with a unique ChargerID; scopes, sessions, card restrictions, and the panel are all keyed by charger id. Gun display names come from the `"chargers"` config section (not hardcoded).
|
||
- **Multi-user auth** (2026-07-11, replaced the interim `api_token`): username/password users with permission scopes — `charger:<cp>:<gun>`, `relay:<name>`, `admin` — full model in [[authorization]]. Stdlib crypto only (PBKDF2 + HMAC sessions). Zero users = open API (startup warns); bootstrap via `python -m backend.users add <name> --scopes admin`.
|
||
- Remote starts run under the calling user's own idTag (`app-<name>`, auto-enrolled) → per-person session attribution.
|
||
- **Consumption tracking** (`store.py`, 2026-07-11): every `StartTransaction` opens a row in `backend.db` with a resolved "who" (allowlist name or username); `StopTransaction` closes it and computes Wh from the meter diff; `MeterValues` rows land in a `samples` table (energy/power/SoC, kW→W normalized). Transaction ids continue from `MAX(tx)` across restarts, and stop-by-tx falls back to the store so sessions running through a backend restart stay stoppable.
|
||
- Relay calls are blocking tinytuya I/O, run via `asyncio.to_thread` so the OCPP socket never stalls.
|
||
- Venv at repo root (`../venv/`, Python 3.13); deps pinned in `backend/requirements.txt` (fastapi, uvicorn, websockets, ocpp, tinytuya) — the auth system added none.
|
||
- ✅ Smoke-tested 2026-07-11 (45 checks, isolated temp db via the `BACKEND_DB` env override): REST surface, allowlist CRUD incl. gun-restricted cards, login/sessions/scopes, user/relay/charger CRUD, the full consumption pipeline (start → meter sample → stop → kWh → visibility filtering), static panel serving, and a fake charge point over the real WS route.
|
||
- ✅ **Live charger connected** (2026-07-11 evening): `eu092025` dials the backend (events.jsonl). ⚠️ Panel not yet exercised from a real phone; relays unconfigured until the [[wifi-relays|key extraction]] is done.
|
||
|
||
## Web panel notes
|
||
|
||
Vanilla JS on purpose (no framework, no CDN — the panel must work with NetBird-only reachability). Start button enables only when the gun reports `Preparing`/`Available` **and** the user holds that gun's scope. Gun cards show who is charging and since when; History tab lists who/when/kWh; Admin tab (admin scope only) manages allowlist (incl. per-gun cards + "seen but not enrolled" quick-enroll), users, and the learn/enforce toggle. Trivial service worker = installable ("add to home screen") without cache-staleness risk.
|
||
|
||
## Deliberately deferred
|
||
|
||
SSE live push (the panel polls), per-session charts from the `samples` table (data is already collected), auto-interrogation on connect (manual `POST /api/charger/probe`).
|